ASTM B228-2011a(2016) Standard Specification for Concentric-Lay-Stranded Copper-Clad Steel Conductors《同心式绞合铜包钢导体的标准规格》.pdf
《ASTM B228-2011a(2016) Standard Specification for Concentric-Lay-Stranded Copper-Clad Steel Conductors《同心式绞合铜包钢导体的标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM B228-2011a(2016) Standard Specification for Concentric-Lay-Stranded Copper-Clad Steel Conductors《同心式绞合铜包钢导体的标准规格》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: B228 11a (Reapproved 2016)Standard Specification forConcentric-Lay-Stranded Copper-Clad Steel Conductors1This standard is issued under the fixed designation B228; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the yea
2、r of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1. Scope1.1 This specification covers b
3、are concentric-lay-strandedconductors made from bare round copper-clad steel wires forgeneral use for electrical purposes.1.2 For the purpose of this specification, conductors areclassified as follows: Grade 40 HS, Grade 30 HS, Grade 30EHS, Grade 40 DSA, and Grade 30 DSA.The grades covered by this s
4、pecification correspond to thefollowing commercial designations:Grade 40 HS, High Strength, 40% Conductivity, Hard DrawnGrade 30 HS, High Strength, 30% Conductivity, Hard DrawnGrade 30 EHS, Extra High Strength, 30% Conductivity, Hard DrawnGrade 40 DSA, 40% Conductivity, Dead Soft AnnealedGrade 30 DS
5、A, 30% Conductivity, Dead Soft Annealed1.3 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.4 This standard does not purport to address
6、all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 The following documents of the iss
7、ue in effect on thedate of material purchase form a part of this specification to theextent referenced herein:2.2 ASTM Standards:2B227 Specification for Hard-Drawn Copper-Clad Steel WireB354 Terminology Relating to Uninsulated Metallic Electri-cal ConductorsE29 Practice for Using Significant Digits
8、in Test Data toDetermine Conformance with SpecificationsB910/B910M Specification for Annealed Copper-Clad SteelWire2.3 ANSI Standards:C42Definitions of Electrical Terms32.4 National Institute of Standards and Technology:NBS Handbook 100Copper Wire Tables43. Ordering Information3.1 Orders for materia
9、l under this specification shall includethe following information:3.1.1 Quantity of each size and grade;3.1.2 Conductor size: approximate diameter in fractions ofan inch, or number and AWG size of individual wires (Section7 and Table 1);3.1.3 Grade (see 1.2 and Table 1);3.1.4 Direction of lay of out
10、er layer, if other than left-hand(see 6.3);3.1.5 When physical tests shall be made (see 8.2);3.1.6 Package size (see 13.1);3.1.7 Special package marking, if required (Section 12);3.1.8 Lagging, if required (see 13.2); and3.1.9 Place of inspection (Section 14).3.2 In addition, Supplementary Requireme
11、nts shall applyonly when specified by the purchaser in the inquiry, contract, orpurchase order for direct procurement by agencies of the U. S.Government (S1, S2, and S3).4. Material for Wires4.1 The purchaser shall specify the grade of wire to be usedin the conductor.4.2 Before stranding, the copper
12、-clad steel wire shall meetall the requirements of Specification B227 for Grade 40 HS,Grade 30 HS and Grade 30 EHS and the requirements ofSpecification B910/B910M for Grade 40 DSA and Grade 30DSA.1This specification is under the jurisdiction of ASTM Committee B01 onElectrical Conductors and is the d
13、irect responsibility of Subcommittee B01.06 onBi-Metallic Conductors.Current edition approved April 1, 2016. Published April 2016. Originallyapproved in 1948. Last previous edition approved in 2011 as B228 11a. DOI:10.1520/B0228-11AR16.2For referenced ASTM standards, visit the ASTM website, www.astm
14、.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.or
15、g.4Available from National Institute of Standards and Technology (NIST), 100Bureau Dr., Stop 1070, Gaithersburg, MD 20899-1070, http:/www.nist.gov.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States14.3 All wires in the conductor shall be
16、 of the same grade andquality.5. Joints5.1 Joints or splices may be made in the finished individualcopper-clad steel wires composing concentric-lay-strandedconductors, using more than three wires provided that suchjoints or splices have a protection equivalent to that of the wireitself and that they
17、 do not decrease the strength of the finishedstranded conductor below the minimum breaking strengthshown in Table 1. Such joints or splices shall be not closer than50 ft (15 m) to any other joint in the same layer in theconductor (Note 1).NOTE 1Joints or splices in individual copper-clad steel wires
18、 in theirfinished size are made by electrical butt welding. Two types of joints areused and are described as follows:(a) Weld-Annealed JointsAfter butt welding, the wire is annealed fora distance of approximately 5 in. (127 mm) on each side of the weld. Theweld is then protected from corrosion with
19、one of two approaches:1. A snug fitting seamless copper sleeve which extends at least38 in.(9.5 mm) on each side of the weld and which is thoroughly sealed to thewire with solder. The wall thickness of the sleeve is at least 10 % of theradius of the wire.2. Protect the weld from corrosion and ensure
20、 acceptable conductivitythrough the use of a silver solder that extends at least 3/8 in. (9.5 mm) oneach side of the weld.This type of joint is applicable for 7, 12, and 19 wire strandedconfigurations. When joints made on annealed individual wires, thecompleted stranded conductor is required to have
21、 the full rated strength.For hard drawn material, this joint has a tensile strength of approximately60 000 psi (415 MPa). This is less than the strength of the individualwires, but an allowance is made for this in the rated strength of theconductor as a whole. The completed conductor when containing
22、 suchjoints is required to have the full rated strength. Other protection methodsmay also be used as agreed upon between the purchaser and manufacturer.This type of joint is but slightly larger than the wire itself and isapplicable for 7, 12, and 19-wire stranded conductors.(b) Compression-Weld Join
23、tsCompression-weld joints differ fromweld-annealed joints in that the wire is not annealed after the butt-weldingoperation but is reinforced with a hard-drawn, seamless, silicon-tin bronzesleeve which is applied by means of a hydraulic compressor over the weld.This sleeve is covered with solder so a
24、s to completely seal the ends. Thesesleeves have a wall thickness of 25 to 50 % of the radius of the wire,depending on the wire size. Their use is usually limited to 3-wireconductors where the relatively large diameter is not objectionable. ThisTABLE 1 Construction Requirements and Breaking Strength
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMB2282011A2016STANDARDSPECIFICATIONFORCONCENTRICLAYSTRANDEDCOPPERCLADSTEELCONDUCTORS 同心 式绞合铜 包钢 导体

链接地址:http://www.mydoc123.com/p-460679.html