ASTM A712-2014 Standard Test Method for Electrical Resistivity of Soft Magnetic Alloys《软磁性合金电阻率测定用标准试验方法》.pdf
《ASTM A712-2014 Standard Test Method for Electrical Resistivity of Soft Magnetic Alloys《软磁性合金电阻率测定用标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM A712-2014 Standard Test Method for Electrical Resistivity of Soft Magnetic Alloys《软磁性合金电阻率测定用标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: A712 07 (Reapproved 2013)A712 14Standard Test Method forElectrical Resistivity of Soft Magnetic Alloys1This standard is issued under the fixed designation A712; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year
2、of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the measurement of electrical resistivity of strip or bar specimens of soft magnetic alloys
3、.1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish
4、appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2A34/A34M Practice for Sampling and Procurement Testing of Magnetic Materials3. Summary of Test Method3.1 The electrical resistance of a 0.25-m long
5、 (minimum) test specimen is measured with a Kelvin-type resistance bridge or adigital multimeterohmmeter or the potentiometer-ammeter method. The resistivity is then calculated from the resistancemeasurement and the dimensions of the specimen and is known as the electrical resistivity of the materia
6、l. This value is equal tothe resistance between opposite faces of a cube of unit dimensions.4. Significance and Use4.1 This test method is suitable for the measurement of the electrical resistivity of specimens of soft magnetic materials.4.2 The reproducibility and repeatability of this test method
7、are such that it is suitable for design, specification acceptance,service evaluation, quality assurance, and research and development.5. Apparatus5.1 Kelvin-type resistance bridge or a digital multimeter ohmmeter (Note 1) or a dc potentiometer and dc ammeter providingresistance measurements to an ac
8、curacy within 0.5 % of the accepted true value.NOTE 1A digital multimeter with a four-wire resistance measuring capability can be substituted for a digital ohmmeter.6. Sampling6.1 Samples shall be representative of the material in the physical condition as shipped or agreed upon by the producer and
9、theuser.7. Test Specimen7.1 The test specimen shall be a straight strip or bar or wire of substantially uniform cross-sectional area.7.2 It shall have a minimum length of 0.25 m. Strip specimens preferably should have a uniform width of 0.03 m minimum,unless not available.7.2.1 If width of the strip
10、 material to be sampled prevents obtaining a sample of 0.03-m minimum width, the specimen widthto be used shall be the maximum obtainable and shall be agreed upon between the producer and the user.1 This test method is under the jurisdiction of ASTM Committee A06 on Magnetic Properties and is the di
11、rect responsibility of Subcommittee A06.01 on Test Methods.Current edition approved May 1, 2013May 1, 2014. Published July 2013May 2014. Originally approved in 1975. Last previous edition approved in 20072013 as A71207.07 (2013). DOI: 10.1520/A0712-07R13.10.1520/A0712-14.2 For referencedASTM standar
12、ds, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM
13、 standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published b
14、y ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States17.2.1 Bars and wires having circular, rectangular, or other sections shall be used in the sectional dimensions as produced, unlessthey ar
15、e so large as to require cutting a representative sample of suitable dimensions.7.3 It shall be free of obvious surface defects.7.4 The surface shall be cleaned by wiping with a cloth. Oil and grease, if present on the surface, shall be removed with asuitable solvent. Normal surface oxide or core pl
16、ating need not be removed except in areas in which it is necessary to makesatisfactory electrical contact.8. Procedure8.1 Measure the electrical resistance of the test specimen using a Kelvin-type resistance bridge or a digital multimeterohmmeteror potentiometer-ammeter system having separate curren
17、t and potential leads.8.2 For strip specimens, measure the length of the test specimen to within 60.1 % and weigh the specimen using a balance orscale capable of determining the mass within 60.1 %. Determine the average cross-sectional area using Eq 1.8.3 For bar or wire specimens, determine the cro
18、ss-sectional area by direct measurement using calipers or micrometers capableof measuring within 60.1 %.8.4 The distance between each potential lead contact and the corresponding current lead contact shall be at least twice the widthof the test specimen with the two potential contacts lying between
19、the current contacts. The distance between the potential contactsshall be not less than 0.12 m.m and shall be known to within 60.1 %.8.5 The dimension of each potential contact in the direction of the length of the specimen shall be not more than 0.5 % of thedistance between potential contacts.8.6 T
20、he contacts to the specimen shall be located centrally with respect to the specimens width dimension, and the currentcontacts shall cover more than 80 % of the width. A reliable contact shall be made with the specimen by both the current andpotential leads.8.7 Specimen temperature during test should
21、 be about 25C.shall be 25 6 5C.8.8 To eliminate errors as a result of contact potential, take two readings, one direct and one with the current reversed, in closesuccession.8.9 The electrical current in the test specimen must be limited to avoid overheating but must be adequate to provide sufficient
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMA7122014STANDARDTESTMETHODFORELECTRICALRESISTIVITYOFSOFTMAGNETICALLOYS 磁性 合金 电阻率 测定 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-459267.html