ASHRAE HVAC SYSTEMS AND EQUIPMENT IP ADD AND CORR-2012 Additions and Corrections.pdf
《ASHRAE HVAC SYSTEMS AND EQUIPMENT IP ADD AND CORR-2012 Additions and Corrections.pdf》由会员分享,可在线阅读,更多相关《ASHRAE HVAC SYSTEMS AND EQUIPMENT IP ADD AND CORR-2012 Additions and Corrections.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、A.1ASHRAE HANDBOOKAdditions and CorrectionsThis report includes additional information, and technical errorsfound between June 15, 2009, and April 3, 2012, in the inch-pound(I-P) editions of the 2009, 2010, and 2011 ASHRAE Handbookvolumes. Occasional typographical errors and nonstandard symbollabels
2、 will be corrected in future volumes. The most current list ofHandbook additions and corrections is on the ASHRAE Web site(www.ashrae.org).The authors and editor encourage you to notify them if youfind other technical errors. Please send corrections to: HandbookEditor, ASHRAE, 1791 Tullie Circle NE,
3、 Atlanta, GA 30329, ore-mail mowenashrae.org.2009 FundamentalsContributors List. For Ch. 15, add the following contributors:Hakim Elmahdy, National Research Council of Canada; BrianCrooks; John L. Wright, University of Waterloo; and William R.McCluney, SunPine Consulting.p. 1.6, Table 2. Correct val
4、ues for ssfor temperatures from 100 to200F are given at right.p. 1.8, Table 3. The horizontal line between the two rows for 32Fmarks the transition from saturated solid to saturated liquid for thefirst subcolumns under Specific Volume, Specific Enthalpy, andSpecific Entropy.pp. 1.9-1.11, Table 3. In
5、 the column headings, change “Sat. Solid”to “Sat. Liquid.”p. 1.13, top of 1st col. The units for p should be psia.p. 1.13, 1st col. The reference to Eq. (38) in Chapter 5 should be toChapter 6.p. 1.16, Example 3. The reference to Table 2 should be to Table 3.The value for hw2should be 18.07, which m
6、akes the result usingEq. (45) 10,154 Btu/min, or 50.77 tons of refrigeration.p. 3.2, 2nd col., last paragraph. Delete the second instance of thesentence: “The terms EMand HM(= EM/g) are defined as positive,and represent energy added to the fluid by pumps or blowers.”p. 4.19, Table 8, Eq. (T8.12). Ch
7、ange 0.37 to 0.037.p. 4.22, Table 10. Correct Eqs. (T10.1) and (T10.7) as follows:(T10.1)(T10.7)p. 4.24, Table 11. In the Muley and Manglik (1999) equation forNu, the last line should read “ Re0.7280.0543 sin(90)/45+3.7.”p. 9.19, Eq. (79). The equation should be toc= 54.1 + 0.31tout.p. 9.17, between
8、 Eqs. (64) and (65). The reference to Equation (58)should be to Equation (60).p. 13.14, 2nd col., 3rd full paragraph. The equation should read.p. 14.1, 1st paragraph. The StationFinder utility is included onlywith the HandbookCD+ version of this chapter, not with the CD-ROM included with the print e
9、dition.p. 14.7, Eq. (5). Add a closing parenthesis at the end of the equation.p. 14.8, bottom of page. The first column should end with “the fol-lowing equation provides sufficient accuracy.” The line beginning“Solution:” should be the next-to-last line in the second column.p. 14.9, Eq. (20). The fi
10、rst operator should be +, not .Ch. 14, Appendix: Design Conditions for Selected Locations.Richmond International Airport belongs in Virginia, not North Car-olina. The 99% and 99.6% heating design dry-bulb temperatures forthe following Alaska stations should be as follows:1expN 1 cr+1 cr+-1expcrcr- P
11、RairT=Table 2 Thermodynamic Properties of Moist Air at Standard Atmospheric Pressure, 14.696 psia(2009 Fundamentals, Chapter 1, p. 6; partial)Temp., F tssTemp., F tss100 0.1376 150 0.4855101 0.1408 151 0.4995102 0.1442 152 0.5140103 0.1476 153 0.5291104 0.1511 154 0.5447105 0.1547 155 0.5609106 0.15
12、84 156 0.5778107 0.1622 157 0.5953108 0.1661 158 0.6136109 0.1701 159 0.6325110 0.1742 160 0.6523111 0.1784 161 0.6728112 0.1828 162 0.6943113 0.1872 163 0.7167114 0.1918 164 0.7400115 0.1965 165 0.7644116 0.2013 166 0.7900117 0.2062 167 0.8167118 0.2113 168 0.8447119 0.2165 169 0.8741120 0.2219 170
13、 0.9049121 0.2274 171 0.9372122 0.2331 172 0.9713123 0.2389 173 1.0072124 0.2449 174 1.0450125 0.2510 175 1.0849126 0.2574 176 1.1271127 0.2639 177 1.1717128 0.2706 178 1.2190129 0.2776 179 1.2693130 0.2847 180 1.3228131 0.2920 181 1.3798132 0.2996 182 1.4406133 0.3074 183 1.5057134 0.3154 184 1.575
14、5135 0.3236 185 1.6506136 0.3322 186 1.7315137 0.3410 187 1.8189138 0.3500 188 1.9136139 0.3594 189 2.0167140 0.3691 190 2.1291141 0.3790 191 2.2524142 0.3894 192 2.3880143 0.4000 193 2.5379144 0.4110 194 2.7046145 0.4224 195 2.8908146 0.4341 196 3.1005147 0.4463 197 3.3381148 0.4589 198 3.6097149 0
15、.4720 199 3.9232200 4.2889A.2 20092011 ASHRAE Handbook Additions and CorrectionsCh. 14, Appendix: Design Conditions for Selected Locations, andClimatic Design Conditions Tables (on the CD-ROM). RichmondInternational Airport belongs in Virginia, not North Carolina. Themain entry for Taiwan should rea
16、d “Taiwan.” In the Russian Feder-ation, station UST-ISIM, WMO ID 283820, the longitude should be71.18 E. Hong Kong International (WMO ID 450070) and HongKong Observatory (WMO ID 450050) should appear under HongKong rather than China. Correct the following latitudes and longi-tudes:p. 15.4, 1st col.
17、In the definitions after Eq. (8), the unit for L shouldbe inches.p. 15.11, Example 2, Solution. The second reference to Table 4should be to Table 1.p. 15.16, 1st col., top. Add “when” before “greater accuracy isdesired.”p. 15.29, Table 12. Change the title to read, “Solar Heat Gain Coef-ficients and
18、 U-Factors for Standard hollow Glass Block Wall Panels.”p. 15.60, Symbols. Add the following definition: “FR= radiant frac-tion.”p. 15.62, References. Add the following source before LBL 2003:Laoudi, A., A.D. Galasiu, M.R. Atif, and A. Haqqani. 2003. SkyVision: Asoftware tool to calculate the optica
19、l characteristics and daylighting per-formance of skylights. Building Simulation, 8th IBPSA Conference,Eindhoven, Netherlands, pp. 705-712.p. 16.7, Eq. (26). On the third line, change “Cp(3) Cp(4)” to“Cp(3) + Cp(4).”p. 16.23, Eq. (48). The equation should use the absolute value of t.p. 17.7. For Eq.
20、 (11), the correct equation is as follows:(11)In the definitions after Eq. (18), change qvnt,lto qvi.l.p. 17.8, Eq. (21). The closing parenthesis should be at the end of theequation.p. 18.2, 2nd col., Cooling Load Calculations in Practice section.On the third line, change “filtration” to “infiltrati
21、on.”pp. 18.8-18.11, Tables 5A to 5E. Items with an asterisk appear onlyin Swierzycna (2009); all others appear in both Swierzycna (2008)and (2009).p. 18.31, Eq. (39). The denominator of the first fraction should be(z2 z1).p. 18.31, Eq. (40). The correct equation is as follows:(40)p. 18.33, 2nd col.
22、In the list of variables under item 2, Tr= room orreturn air temperature, F.p. 18.41, Table 29. Correct the diffuse solar heat gain values for thefollowing rows:p. 18.43, Table 31. For the convective and radiant columns, use thevalues shown below.p. 19.18, Eqs. (55), (57), and (59). Multiply the rig
23、ht-hand side ofthe equation by the conversion factor 24 h/day. For Eq. (57), alsochange hto c.p. 20.13, 2nd col., Air Diffusion Performance Index (ADPI), 1stparagraph. The reference should be to Eq. (15).p. 20.14, 2nd col., Convective Flows Associated with Space HeatSources, last paragraph. The refe
24、rence should be to Eq. (12). p. 21.6, Eq. (19). The correct equation is as follows:(19)p. 21.33, Table for ED5-1, Wye, 30, Converging. In the expres-sion centered over the table columns, change Qbto Qs.pp. 21.42-44, Tables for ED5-3, Dc 10 in., Converging. In theexpressions centered over the table c
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASHRAEHVACSYSTEMSANDEQUIPMENTIPADDANDCORR2012ADDITIONSANDCORRECTIONSPDF

链接地址:http://www.mydoc123.com/p-455031.html