ASHRAE 90429-2008 Structural and Vibration Guidelines for Datacom Equipment Centers《数据通讯设备中心的结构和振动准则》.pdf
《ASHRAE 90429-2008 Structural and Vibration Guidelines for Datacom Equipment Centers《数据通讯设备中心的结构和振动准则》.pdf》由会员分享,可在线阅读,更多相关《ASHRAE 90429-2008 Structural and Vibration Guidelines for Datacom Equipment Centers《数据通讯设备中心的结构和振动准则》.pdf(177页珍藏版)》请在麦多课文档分享上搜索。
1、 Structural and Vibration Guidelines for Datacom Equipment Centers2007, American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. (www.ashrae.org). For personal use only. Additional reproduction, distribution, or transmission in either print or digital form is not permitted wit
2、hout ASHRAEs prior written permission.This publication was prepared in cooperation with TC 9.9, Mission Critical Facilities,Technology Spaces, and Electronic Equipment.Any updates/errata to this publication will be posted on the ASHRAE Web site at www.ashrae.org/publicationupdates.American Society o
3、f Heating, Refrigeratingand Air-Conditioning Engineers, Inc.Structural and Vibration Guidelines for Datacom Equipment CentersISBN: 978-1-933742-20-52007 American Society of Heating, Refrigeratingand Air-Conditioning Engineers, Inc.1791 Tullie Circle, NEAtlanta, GA 30329www.ashrae.orgAll rights reser
4、ved.Printed in the United States of AmericaPrinted on 10% post-consumer waste using soy-based inks.Cover design by J. Lombardo.ASHRAE has compiled this publication with care, but ASHRAE has not investigated, and ASHRAEexpressly disclaims any duty to investigate, any product, service, process, proced
5、ure, design, or the likethat may be described herein. The appearance of any technical data or editorial material in this publi-cation does not constitute endorsement, warranty, or guaranty by ASHRAE of any product, service,process, procedure, design, or the like. ASHRAE does not warrant that the inf
6、ormation in the publi-cation is free of errors, and ASHRAE does not necessarily agree with any statement or opinion in thispublication. The entire risk of the use of any information in this publication is assumed by the user.No part of this book may be reproduced without permission in writing from A
7、SHRAE, except by areviewer who may quote brief passages or reproduce illustrations in a review with appropriate credit;nor may any part of this book be reproduced, stored in a retrieval system, or transmitted in any wayor by any meanselectronic, photocopying, recording, or otherwithout permission in
8、 writing fromASHRAE._Library of Congress Cataloging-in-Publication DataStructural and vibration guidelines for datacom equipment centers.p. cm. - (ASHRAE datacom series)Summary: “Provides basics for addressing the structural and vibration performance (resistance against wind, snow, and seismic assau
9、lt) of datacom equipment centers, focusing on the facility (envelope, beams, columns, floor slabs, roof slabs), the building infrastructure (power, cooling, flooring, ceiling systems), and the datacom equipment (servers, storage, tape drives, racks, network equipment)“-Provided by publisher.Includes
10、 bibliographical references and index.ISBN 978-1-933742-20-5 (softcover)1. Structural design. 2. Data processing service centers-Design and construction. 3. Buildings-Vibration. 4. Earthquake resistant design. 5. Data processing service centers-Protection. 6. Electronic digital computers-Protection.
11、 I. American Society of Heating, Refrigerating and Air-Conditioning Engineers. TH1094.S77 2007725.23-dc222007046368ASHRAE STAFFSPECIAL PUBLICATIONSChristina HelmsEditorCindy Sheffield MichaelsAssociate EditorMichshell PhillipsAdministrative AssistantPUBLISHING SERVICESDavid SoltisManagerTracy Becker
12、Graphic Applications SpecialistJayne JacksonPublication Traffic AdministratorPUBLISHERW. Stephen ComstockContentsAcknowledgments. ixPart IIntroduction and Best PracticesChapter 1 Introduction.31.1 Overview of this Book31.2 Overview of the Datacom Industry 51.3 Overview of ASHRAE Technical Committee
13、9.9 .61.4 Overview of the ASHRAE Datacom Series .61.5 Document Flow .71.6 Primary Users for This Document .7Chapter 2 Best Practices.92.2 Building StructuresNew Buildings and Additions .92.3 Building StructuresRenovations, Relocations, and Changes 102.4 Building Infrastructure .112.5 Datacom Equipme
14、nt11Part IIBuilding StructureChapter 3 Building Structures Overview .153.1 Introduction153.2 Some Basics .153.3 Submissions to Agencies 183.4 Basic Definitions19vi ContentsChapter 4 New Structures .214.1 Initial Investigation .214.2 Coordination 224.3 Establish Design Criteria .22Chapter 5 Existing
15、Structures and Additions295.1 Initial Investigation .295.2 Coordination of New with Existing Structures305.3 New Components 335.4 Reinforcement of Existing Structure 34Chapter 6 Types of Building Structures.376.1 Overview .376.2 Pre-Engineered Metal Buildings. .376.3 Braced Frame or Shear Wall-Type
16、Structures. 386.4 Moment Resisting Frame Systems416.5 Combination of Framing Systems41Part IIIBuilding InfrastructureChapter 7 Building Infrastructure Overview457.1 Overview457.2 Interior Building Infrastructure .457.3 Exterior Building Infrastructure 47Chapter 8 Structural Considerations for Infras
17、tructure .558.1 Overview558.2 Support558.3 Anchoring 578.4 Infrastructure Expansion/Contraction 59Chapter 9 Raised-Access Floor Systems 619.1 Overview619.2 Raised-Access Floor Components619.3 Raised-Access Floor Structure Design Guidelines639.4 Seismic Performance of Raised-Access Floors.66Chapter 1
18、0 Vibration Sources and Control7110.1 Overview of Vibration Sources 7110.2 Overview of Vibration Isolation 7110.3 Selection of Vibration Isolators73Structural and Vibration Guidelines for Datacom Equipment Centers vii10.4 Vibration Isolation within the Datacom Equipment Room .7310.5 Vibration Isolat
19、ion Adjacent to the Datacom Equipment Room .74Part IVDatacom EquipmentChapter 11 Shock and Vibration Testing on Datacom Equipment .7911.1 Basic Definitions7911.2 Overview of Vibration Sources 8011.3 Datacom Equipment Shock and Vibration Testing 8311.4 Shock and Vibration Test Guidelines for Datacom
20、Infrastructure and Cooling Equipment .89Chapter 12 Seismic Anchorage of Datacom Equipment9512.1 Overview 9512.2 Nonstructural Seismic Provisions of Building Codes.9512.3 Seismicity in the United States9612.4 Seismic Design Category9712.5 Properly Applying Anchorage Forces9712.6 Protection of Server
21、Cabinets on Raised-Access Floors 98Chapter 13 Analysis of Datacom Equipment and Seismic Anchorage Systems 10713.1 Overview . 10713.2 Basic Definitions10713.3 Datacom Equipment Frame.10813.4 Finite Element Model Construction and Validation10813.5 Evaluation of Earthquake Anchorage Systems .11013.6 Ev
22、aluation of Structural Add-On Supports 113References and Bibliography117Appendix A Codes for Building Structures and Structural Components121Appendix B Weights of Materials.125Appendix C Raised-Access Floor Calculations133C.1 Raised-Access Floor Panel Loading Definitions133C.2 Floor Loading 134viii
23、ContentsC.3 Floor Loading Calculations135C.4 Structural Guidelines for Raised-Access Floor Systems.137Appendix D Data Center Vibration Measurement.141D.1 Overview .141D.2 Introduction141D.3 Typical Operational Vibration and Shock Testing.142D.4 Typical Operational Vibration and Shock Magnitude Recor
24、ded in a Data Center144D.5 Monitoring Floor Vibration in Data Centers .145D.6 Best Practices146Appendix E Component Anchorage Forces .149E.1 Relative Location Factor (1 + 2z/h)149E.2 Component Importance Factor (Ip)150E.3 Component Amplification Factor (ap).150E.4 Component Response Modification Fac
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASHRAE904292008STRUCTURALANDVIBRATIONGUIDELINESFORDATACOMEQUIPMENTCENTERS 数据 通讯设备 中心 结构 振动 准则 PDF

链接地址:http://www.mydoc123.com/p-454462.html