ARMY MIL-PRF-44408 C-1996 SHELTER ELECTRICAL EQUIPMENT LIGHTWEIGHT《轻型电气设备架》.pdf
《ARMY MIL-PRF-44408 C-1996 SHELTER ELECTRICAL EQUIPMENT LIGHTWEIGHT《轻型电气设备架》.pdf》由会员分享,可在线阅读,更多相关《ARMY MIL-PRF-44408 C-1996 SHELTER ELECTRICAL EQUIPMENT LIGHTWEIGHT《轻型电气设备架》.pdf(21页珍藏版)》请在麦多课文档分享上搜索。
1、Beneficial comments (recommendations, additions, deletions) and any pertinentdata which may be of use in improving this document should be addressed to:Commander, U.S. Army Natick Research and Development Center, ATTN: SSCNC-WST,Natick, MA 01760-5018 by using the self addressed Standardization Docum
2、entImprovement Proposal (DD Form 1426) appearing at the end of this document or byletter.AMSC N/A FSC 5411DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited.INCH-POUNDMIL-PRF-44408C31 October 1996SUPERSEDINGMIL-S-44408B28 January 1994PERFORMANCE SPECIFICATIONSHELTER, EL
3、ECTRICAL EQUIPMENT, LIGHTWEIGHTThis specification is approved for use by all Departments and Agencies of theDepartment of Defense.1. SCOPE1.1 Scope. This document covers three types of lightweight electricalequipment shelters designed for transport on both the M1037 and M1097 HighMobility Multipurpo
4、se Wheeled Vehicle (HMMWV). These shelters are transported byrail, air, marine and highway when mounted or dismounted from their vehicles.1.2 Classification. The shelters will be of the following types, as specified(see 6.2).Type I - Shelter, Electrical Equipment, Lightweight (w/o Tunnel,17-2-0035-1
5、)Type II - Shelter, Electrical Equipment, Lightweight, Modified, SICPS(w/ Tunnel, Drain holes in tunnel, Secondary Exit, and Ventilation Port, 17-2-0035-2)Type III - Shelter, Electrical Equipment, Lightweight, Modified, General Purpose (w/ Tunnel, 17-2-0035-3)2. APPLICABLE DOCUMENTS2.1 General. The
6、documents listed in this section are specified in sections 3and 4 of this specification. The section does not include documents cited inother sections of this specification or recommended for additional information oras examples. While every effort has been made to ensure the completeness of thislis
7、t, document users are cautioned that they must meet all specified requirementsdocuments cited in sections 3 and 4 of this specification, whether or not they arelisted.2.2 Government Documents.2.2.1 Specifications, standards, and handbooks. The following specifications,standards, and handbooks form a
8、 part of this document to the extent specifiedherein. Unless otherwise specified, the issues of these documents are thoselisted in the issue of the Department of Defense Index of Specifications andStandards (DoDISS) and supplement thereto, cited in the solicitation (see 6.2).Provided by IHSNot for R
9、esaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-44408C2SPECIFICATIONSDEPARTMENT OF DEFENSEMIL-T-704 - Treatment and Painting of MaterialMIL-M-8090 - Mobility, Towed Aerospace Ground Equipment, GeneralRequirements forSTANDARDSDEPARTMENT OF DEFENSEMIL-STD-209 - Slingi
10、ng and Tiedown Provisions for Lifting and TyingDown Military EquipmentMIL-STD-810 - Environmental Test Methods and Engineering GuidelinesMIL-STD-1366 - Transportability CriteriaMIL-STD-1791 - Designing for Internal Aerial Delivery in Fixed WingedAircraft(Unless otherwise indicated, copies of the abo
11、ve specifications, standards,and handbooks are available from the Standardization Document Order Desk, 700Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.)2.2.2 Other Government documents, drawings, and publications. The followingother Government documents, drawings and publications form a
12、part of this documentto the extent specified herein. Unless otherwise specified, the issues are thosecited in the solicitation.U.S. ARMY NATICK RESEARCH, DEVELOPMENT AND ENGINEERING CENTER17-1-8565 - Extension Kit, Pintle17-1-8584 - Mounting Kit Shelter To HMMWV17-2-0035 - Interface Control Drawing
13、for, Shelter, Electrical Equipment,Lightweight, Types I, II and III13228E1639 - Standard Camouflage Pattern For Shelter, Lightweight,Multipurpose(Copies of drawings are available from the U.S. Army Natick Research,Development, and Engineering Center, ATTN: SSCNC-WST, Natick, MA 10760-5018.)2.3 Non-G
14、overnment publications. The following documents form a part of thisdocument to the extent specified herein. Unless otherwise specified, the issuesof the documents which are DoD adopted are those listed in the issue of the DoDISScited in the solicitation. Unless otherwise specified, the issues of the
15、documents not listed in the DoDISS are the issues of the documents cited in thesolicitation (see 6.2).AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM)PS 27 - 95 - Provisional Standard Specification for Engineering and DesignCriteria for Rigid Wall Relocatable Structures(Application for copies shoul
16、d be addressed to the American Society forTesting and Materials, 1916 Race Street, Philadelphia PA 19103.)INSTITUTE OF ELECTRICAL AND ELECTRONIC ENGINEERS (IEEE)IEEE 299-1991 - IEEE Standard Method for Measuring the Effectiveness ofElectromagnetic Shielding EnclosuresProvided by IHSNot for ResaleNo
17、reproduction or networking permitted without license from IHS-,-,-MIL-PRF-44408C3(Application for copies should be addressed to the IEEE Service Center, 445Hoes Lane, Piscataway, NJ 08855-1331.)2.4 Order of precedence. In the event of a conflict between the text of thisdocument and the references ci
18、ted herein, the text of this document takesprecedence. Nothing in this document, however, supersedes applicable laws andregulations unless a specific exemption has been obtained.3. REQUIREMENTS.3.1 First article. When specified (see 6.3), a sample shall be subjected tofirst article inspection in acc
19、ordance with 4.1a. A first article is defined as apreproduction or an initial production sample consisting of one or more of eachtype of completed shelters.3.2 Physical Performance Requirements.3.2.1 Weight and payload. The shelter weight and payload capacity of eachshelter type shall be as listed i
20、n table I. The maximum shelter weight listeddoes not include the weight of the Mounting Kit and Pintle Extension and theirattaching hardware. The shelter shall be capable of accepting the payloaddistribution specified in the contract or purchase order (see 6.2).TABLE I. Weight and Payload CapacityTy
21、pe Maximum ShelterWeightMinimum PayloadCapacityMounting KitIncl. HardwarePintle ExtensionIncl. HardwareI 608 lbs 3300 lbs 88 lbs 50 lbsII 650 lbs 3300 lbs 88 lbs 50 lbsIII 643 lbs 3300 lbs 88 lbs 50 lbs3.2.2 Parts interchangeability.3.2.2.1 Spare parts. The spare parts are listed in table II and are
22、 depicted oninterface drawing number 17-2-0035. All spare parts and related assemblies shallbe functionally and dimensionally interchangeable without modification or reworkof the part, assembly, or shelter.TABLE II. Spare PartsPARTHMMWV Mounting KitPintle Extension KitDoor AssemblyHatch Assembly (Ty
23、pe II)Rear LadderStepsT-bar Door Holder3.2.2.2 Interface parts. The interface parts are listed in table III. Allinterface parts and related assemblies shall be functionally and dimensionallyinterchangeable, without modification or rework of the part, assembly, shelter, orvehicle, with the reference
24、parts listed in table III.Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-44408C4TABLE III. Interface PartsPART REFERENCE PART NO.Mounting Kit, Shelter To HMMWV 17-1-8584-1Extension Kit, Pintle 17-1-8565-13.2.3 Shelter configuration. The shel
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILPRF44408C1996SHELTERELECTRICALEQUIPMENTLIGHTWEIGHT 轻型 电气设备 PDF

链接地址:http://www.mydoc123.com/p-447251.html