1、MIL-PRF-44329C = 9999906 2029782 52T 4 MIL-PRI-44329C (GL) 27 March 1997 SUPERSEDING 2 March 1995 MIL-DTL-443 29B (GL) PERFORMANCE SPECIFICATION KITCHEN, FIELD, MODULAR, COMPONENTS THEREOF This specification is approved for use by the Natick Research, Development and Engineering Center, Department o
2、f the Army, and is available for use by all Departments and Agencies of the Department of Defense (DoD) 1. SCOPE 1.1 Scope. This specification covers the fabricated components of the Modular Field Kitchen (MFK) (see 6.1). 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed in this section are
3、specified in sections 3 and 4 of this specification. This section does not include documents cited in other sections of this specification or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned
4、that they must meet ail specified requirements documents cited in sections 3 and 4 of this specification, whether or not they are listed. 2.2 Government documents. (None). 2.3 Non-Government publications. The following documents form a part of this specification to the extent specified herein. Unles
5、s otherwise specified, the issues of the documents which &e DoD adopted are those listed in the issue of the DoDISS cited in the Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be of use in improving this document should be addressed to: U.S. Axmy Natick
6、Research, Development, and Engineering Center, Natick, MA O 1760-50 1 8 by using the Standardization Document Improvement Proposal D Form 1426) appearing at the end of this document or by letter. AMSC NIA FSC 7360 Provided by IHSNot for ResaleNo reproduction or networking permitted without license f
7、rom IHS-,-,-. MIL-PRF-44329C (GL) solicitation. Unless otherwise specified, the issues of documents not listed in the DoDISS are the issues of the documents cited in the solicitation (see 6.2). NSF INTERNATIONAL CRITERIA C-2 - Special Equipment and/or Devices (Application for copies should be addres
8、sed to NSF International, 3475 Plymouth Road, P.O. Box 130140, Ann Arbor, MI 481 13-0140). 2.4 -e. In the event of a conflict between the text of this document and the references cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws a
9、nd regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 First article. When specified (see 6.2), an MFK shall be subjected to frrst article inspection in accordance with 4.1.1. 3.2 Operatin? reouirements. The MFK components identified in table I (see figures 1 thru 5) shall
10、 satis the following user-oriented requirements. TABLE I. Modular field kitchen components IItern Description Reference Paragraphs Quantity Maximum Weight NA Allowance Each (lbs.) 1 Griddle top 3.2.1 thru 3.2.3 1 82 2 Heater tank, tray pack 3.2.4 thru 3.2.9 1 88 3 Oven, field 3.2.10 thni 3.2.12 2 11
11、0 3.2.13 thru 3.2.17 1 I 175 4 I Steam table body and adapter top I 1 3.2.1 Griddle top. size and configuration. The griddIe body shall be reversible so that either the top or bottom may be used as a cooking surface and the cooking surface shall facilitate drainage of grease. The height of the gridd
12、le top, when mounted securely, on a double-burner rack and a double-burner base (see 6.9.1), shall be 39 If: 1 inch reference figure 1). The griddle top assembly shall have a grease splash guard at each end and at the rear of the griddle. The grease splash guards shall be easily removable for cleani
13、ng. A means shall be provided to guide grease into a grease collector receptacle. A drain slot plug shall prevent undesired draining of grease, 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-44329C 9Ob 2029984 3T2 = MIL-PRF-44329C (GL) 3.2
14、.2 Griddle top. flatness. The griddle top shall remain flat after heating and cooling. 3.2.3 Griddle top. surface. The griddle body shall have a smooth surface that is nontoxic and shall not impart odors, color or taste, or otherwise contribute to the adulteration or contamination of food during nor
15、mal operation. 3.2.4 Heater tank. trav pack. site and configuration. The tray pack heater tank shall have a capacity of not less that 20 gallons of water and 20 tray packs and shall have a visual mark on the inside at the 20-gallon level. The tank assembly shall be approximately 37 inches high (refe
16、rence figure 2) and shall accommodate an M2A burner unit (see 6.9.1). The tank assembly shall have two handles on the fiont and two on the rear that fold down along the tanks vertical surface when not in use. When the handles are utilized, they shall not rotate upward more than approximately 90 degr
17、ees. The heater tank shall be provided with a two-section cover, split in the center, hinged on each side and capable of being secured in the closed position with latches. The heater tank shall contain a drain, a drain bail valve and a drain pipe with a hose adapter. 3.2.5 Heater tank. trav pack. he
18、ating. The heater tank assembly shall pennit water to be rapidly heated, and shall withstand direct heat from the burner unit (see 6.9.1). 3.2.6 Heater tank. trav pack. drainage. The tank drain shall permit rapid drainage. 3.2.7 Heater tank. trav uack. leakage. Tanks shall not leak. 3.2.8 Heater tan
19、k. tray pack. warning plates. Warning plates that speci “Warning, May Be Hot“ shaI1 be mounted to the fiont and back of the tank. Marking shall be durable. 3.2.9 Heater tank. trav pack. operatino instructions plate. An operating instruction decal shall be provided on the front of the tank assembly a
20、nd shall speciQ: 1. Light burner per TM 10-7360-204- 13 &P. 2. Fill with 20 gallons of water for full load of 20 tray packs. 3. Place lighted burner in heater-tank burner rack. 4. Frequently check fuel tank pressure gage during heating cycle. Adjust if 5. Bring water to a boil. 6. Place tray packs i
21、n tank being sure they are completely covered with water. 7. Heat tray packs for 45 minutes. 8. Remove tray packs using tray pack lifter. necessary. 3.2.1 O Oven. field. size and confpration. The oven chamber volume shall be approximately 11 cubic feet and shall accommodate four racks, 20-1/4 inches
22、 long, 23-3/4 inches wide and 14- 1/2 inches high. The overall height of the oven when mounted on a base rack and bumer rack (see 6.9.1) shall be approximately 70 inches. The oven shall be insulated, as appropriate, to insure heat retention. The oven shall be vented (reference figure 3). The oven ch
23、amber shall 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-YY329C 9999906 2029985 239 MIL-PW-44329C (GL) have provisions to locate oven racks in four different positions. Four oven racks shall be provided with each oven. The oven door shal
24、l be provided with a positive locking handle. The field oven shaIl have a two-person carrying handle on each side of the oven. When the handles are utilized, they shall not rotate upward more than approximately 90 degrees. 3.2.1 1 Oven. field. distortiori. There shall not be any distortion of the fi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILPRF44329C1997KITCHENFIELDMODULARCOMPONENTSTHEREOF 零件 厨房 PDF

链接地址:http://www.mydoc123.com/p-447249.html