1、 MIL-PRF-44156E (GL) 1 March 2006 SUPERSEDING MIL-PRF-44156D (GL) 24 February 1997 PERFORMANCE SPECIFICATION KITCHEN, COMPANY LEVEL, FIELD FEEDING (KCLFF), COMPONENTS THEREOF This specification is approved for use by the Natick Research, Development, and Engineering Command, Department of the Army a
2、nd is available for use by all Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This specification covers the fabricated components of the Kitchen, Company Level, Field Feeding (KCLFF). 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed in this section are specified
3、in section 3 of this specification. This section does not include documents cited in other sections of this specification or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned that they must me
4、et all specified requirements documents cited in section 3 of this specification, whether or not they are listed. AMSC N/A FSC 7360 INCH-POUND Comments, suggestions or questions on this document should be addressed to US Army Research, Development and Engineering Command, Natick Soldier Center, AMSR
5、D-NSC-CF-S, 15 Kansas St., Natick, MA 01760-5018 or emailed to Robert.Bernazzaninatick.army.mil. Since contact information can change, you may want to verify the currency of this address information using the ASSIST Online database at http:/assist.daps.dla.mil Provided by IHSNot for ResaleNo reprodu
6、ction or networking permitted without license from IHS-,-,-MIL-PRF-44156E (GL) 2.2 Government documents. (None). 2.3 Non-Government publications. The following documents form a part of this specification to the extent specified herein. Unless otherwise specified, the issues of the documents which ar
7、e DoD adopted are those listed in the issue of the DoDISS cited in the solicitation. Unless otherwise specified, the issues of documents not listed in the DoDISS are the issues of the documents cited in the solicitation (see 6.2). NSF INTERNATIONAL STANDARD NO. 2 - Food Service Equipment STANDARD NO
8、. 4 - Commercial Cooking and Hot Food Storage Equipment CRITERIA C-2 - Special Equipment and/or Devices (Application for copies should be addressed to NSF International, 789 N. Dixboro Road P.O. Box 130140, Ann Arbor, MI 48113-0140). 2.4 Order of precedence. In the event of a conflict between the te
9、xt of this specification and the references cited herein, the text of this specification takes precedence. Nothing in this specification, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 First article. When specified (see 6.2), KC
10、LFF shall be subjected to first article inspection in accordance with 4.1.1. 3.2 Heater Tank operating requirements. The KCLFF component identified in Table I (reference figure 1) shall satisfy the following requirements. TABLE I. Heater Tank component for KCLFF Item No. Description Reference Paragr
11、aph Quantity Maximum Weight (lbs) 1 Heater tank assembly, tray pack 3.2.1 thru 3.2.6 1 88 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-44156E (GL) 3.2.1 Heater tank, tray pack, size and configuration. The tray pack heater tank (reference
12、 figure 1) shall have a capacity of not less than 20 gallons of water and 20 tray packs (reference figure 2) and shall have a visual mark on the inside at the 20-gallon level. The tank assembly shall be approximately 37 inches high and shall accommodate a Modern Burner Unit(MBU) (see 6.6.1). The tan
13、k assembly shall have two handles on the front and two on the rear that fold down along the tanks vertical surfaces when not in use. When the handles are utilized, they shall not rotate upward more than approximately 90 degrees. The heater tank shall be provided with a two- section cover, split in t
14、he center, hinged on each side and capable of being secured in the closed position with latches. Each tank shall contain a drain, a drain ball valve and a drain pipe with a hose adapter. 3.2.2 Heater tank, tray pack, heating. The heater tank assembly shall permit water to be rapidly heated, and shal
15、l withstand direct heat from the burner unit (see 6.6.1). 3.2.3 Heater tank, tray pack, drainage. The tank drain shall permit rapid drainage. 3.2.4 Heater tank, tray pack, leakage. The tank shall not leak. 3.2.5 Heater tank, tray pack, warning plates. Warning plates that specify, “Warning, May Be Ho
16、t“ shall be mounted to the front and back of the tank. Marking shall be durable. 3.2.6 Heater tank, tray pack, operating instructions plate. An operating instruction plate shall be provided on the front of the tank assembly and shall specify the following: “1. Place burner in rack 2. Fill with 20 ga
17、llons of water for full load of 20 tray packs 3. Light burner per TM 10-7310-281-13 &P 4. Bring water to a boil leaving burner on high setting 5. Place tray packs in tank being sure they are completely covered with water 6. Heat tray packs for 45 minutes 8. Remove tray packs using tray pack lifter 9
18、. Shut burner off by pressing stop“ Marking shall be durable. 3.3 Griddle operating requirements. The KCLFF component identified in table II (reference figure 3) shall satisfy the following requirements. 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-
19、,-,-MIL-PRF-44156E (GL) 4 TABLE II. Griddle and base for KCLFF Item No. Description Reference Paragraph Quantity Maximum Weight (lbs) 1 Griddle 3.3.1, 3.3.2 and 3.3.3 1 14 2 Griddle base 3.3.4 1 8 3.3.1 Griddle, size and configuration. The griddle shall be approximately 21 inches long, 18 inches wid
20、e and 1-5/8 inches high, excluding handles, in order to interface with each griddle base. Two handles shall be provided that shall have openings no smaller than 4 inches wide and 1-1/8 inches high. 3.3.2 Griddle, flatness. The griddle shall remain flat after repeated heating and cooling. 3.3.3 Gridd
21、le, surface. The griddle shall have a smooth surface that is nontoxic and shall not impart odors, color or taste, or otherwise contribute to the adulteration or contamination of food during normal operating temperatures. 3.3.4 Griddle base, size and configuration. The griddle shall fit within a rim
22、in the griddle base. The griddle base shall interface with the burner rack and base (see 6.6.1) that are utilized with the cook pot cradle assembly (see 6.7.1). 3.3.5 Chemical resistance. Components listed in table I and table II shall be resistant to the detergents and sanitizers used for washing a
23、nd sanitizing operations. 3.3.6 Safety. Components listed in table I and table II shall be safe to set up, operate, and transport and shall not create personnel hazards. 3.3.7 Sanitation/Cleaning. Food service equipment shall meet the sanitation requirements of NSF/ANSI Standard 2, Food service equi
24、pment. Surfaces shall be smooth, washable, free of unnecessary ledges, projections or crevices, and readily accessible for cleaning. 3.4 Integrated equipment. The KCLFF shall also include the components listed under section 3.4.1. Provided by IHSNot for ResaleNo reproduction or networking permitted
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILPRF44156E2006KITCHENCOMPANYLEVELFIELDFEEDINGKCLFFCOMPONENTSTHEREOF 零件 野外 供给 全体 厨房 KCLFFPDF

链接地址:http://www.mydoc123.com/p-447248.html