ARMY MIL-PRF-44015 A-1997 REFRIGERATOR-CONTAINER FIELD 8 FEET BY 8 FEET BY 10 FEET《8 英尺×8 英尺×10英尺野外冷藏集装箱》.pdf
《ARMY MIL-PRF-44015 A-1997 REFRIGERATOR-CONTAINER FIELD 8 FEET BY 8 FEET BY 10 FEET《8 英尺×8 英尺×10英尺野外冷藏集装箱》.pdf》由会员分享,可在线阅读,更多相关《ARMY MIL-PRF-44015 A-1997 REFRIGERATOR-CONTAINER FIELD 8 FEET BY 8 FEET BY 10 FEET《8 英尺×8 英尺×10英尺野外冷藏集装箱》.pdf(19页珍藏版)》请在麦多课文档分享上搜索。
1、 flIL-PRF-44015A W 9999906 2057342 506 W I INCH POUND MIL-PRF-44015A(GL) 77 October 1997 SUPERSEDING MIL-R-44015(GL) 23 November 1979 PERFORMANCE SPECIFICATION REFRIGERATOR-CONTAINER, FIELD, 8 FEET BY 8 FEET BY 10 FEET This specification is approved for use by the U.S. Army Natick Research, Developm
2、ent and Engineering Center, Department of the Army, and is available for use by all Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 ScoDe. This specification covers an8 foot by 8 foot by 10 foot insulated container for use with a 4,000 British thermal unit (Btu) per hour, electri
3、c motor-driven refrigeration unit. 2. APPLICABLE DOCUMENTS 2.1 Ce neral . The documents listed in this section are This specified in sections 3 and 4 of this specification. section does not include documents cited in other sections of this specification or those recommended for additional informatio
4、n or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned that they must meet all specified requirements documents cited in sections 3 and 4 of this specification, whether or not they are listed. Beneficial comments (recommendations, add
5、itions, deletions) and any pertinent data which may be of use in improving this document should be addressed to: U.S. Army Natick Research, Development and Engineering Center, Natick, MA 01760-5018 by using the Standardization Document Improvement Proposal (DD Form 1426) appearing at the end of this
6、 document or by letter. AMSC N/A FSC 4110 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- MIL-PRF-440b5A 0b 2057343 442 W MIL-PRF- 4 4 O 15A (GL) 2.2 Co vernment documents. 2.2.1 Standard. The following Government standard forms a part of this docum
7、ent to the extent specified herein. Unless otherwise specified, the issues of these documents are those listed in the issue of the Department of Defense Index of Specifications and Standards (DoDISS) and supplement thereto, cited in the solicitation (6.2). STANDARD DEPARTMENT OF DEFENSE MIL-STD-810
8、- Environmental Test Methods and Engineering Guidelines (Unless otherwise indicated, copies of the above standard are available from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094). 2.2.2 Other Government documents. The following other Governmen
9、t document forms a part of this document to the extent specified herein. Unless otherwise specified, the issues are those cited in the solicitation. DEPARTMENT OF TRANSPORTATION (DOT) Code of Federal Regulations Title 49 CFR - Transportation, Parts 450-451 (Application for copies should be addressed
10、 to the Department of Transportation, Superintendent of Documents, Government Printing Office, Washington, DC 204402). 2.3 Non-Government DubJication s. The following documents form a part of this document to the extent specified herein. Unless otherwise Specified, the issues of the documents which
11、are DoD adopted are those listed in the issue of the DoDISS cited in the solicitation. Unless otherwise specified, the issues of documents not listed in the DoDISS are the issues of the documents cited in the solicitation (see 6.2). 2 Provided by IHSNot for ResaleNo reproduction or networking permit
12、ted without license from IHS-,-,-. MIL-PRF-44015A (GL) INTERNATIONAL ORGANIZATION FOR STANDARDIZATION IS0 668 - Series 1 Freight Containers - Classification, IS0 1161 - Series 1 Freight Containers - Corner Fittings IS0 1496-2- Series 1 Freight Containers - Specification and Dimensions and Ratings Te
13、sting Part 2: Thermal Containers National Standards Institute, Inc., 11 West 42nd Street, New York, NY 10036). (Application for copies should be addressed to the American AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM) ASTM F883 - Standard Performance Specification for Padlocks (Application for co
14、pies should be addressed to the American Society for Testing and Materials, 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959) . NSF INTERNATIONAL Standard No. 2 - Food Service Equipment (Application for copies should be addressed to NSF Intl., 3475 Plymouth Road, P.O. Box 1468, Ann Arbor, MI
15、48106). NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) Standard No. 70 - National Electrical Code (Application for copies should be addressed to the National Fire Protection Association, One Battery March Park, Quincy, MA 02269-9101). 2.4 Order of precedence. In the event of a conflict between the text
16、 of this document and the references cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 First article. When specified (see 6.2), a sample shall be s
17、ubjected to first article inspection in accordance with 4.1.1. 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF- 4 4 O 15A ( GL ) 3.2 OD eratinu reeruirements. The container units shall satisfy the following functional, operational and perfo
18、rmance requirements. 3.2.1 He at leakaae. Heat infiltration or loss through the container shall be minimized. 3.2.2 Air leakaue. Air leakage of the container shall be minimized. 3.2.3 Safetv. The container units shall minimize flammability, operational, toxic and personnel hazards. 3.2.4 Drainaae .
19、The container shall have floor drains which provide complete and total drainage of the container. The drains shall open automatically when subjected to pressures above normal internal pressure. closures. The drain openings shall be recessed below the bottom surface of the floor. The drains shall be
20、provided with manual 3.2.5 Door. The door shall be flush with the container exterior when closed. The door shall be provided with a means to prevent door hardware from damaging the exterior container skin when opened. The door opening shall be a minimum of 74 inches in height and 36 inches in width.
21、 External hardware shall be protected from damage and not extend beyond corner fittings. Means shall be provided to hold the doors in the full open position. The door shall open outward from the right. 3.2.6 Door han dle and latch . Thedoor shall have an external handle which shall operate a heavy d
22、uty locking device which shall securely hold the door in the closed position during all modes of shipment and rough handling. provisions to accept a padlock as specified in 3.3.3. padlock in place, the door shall be incapable of being opened from the outside. to allow the door to open from the insid
23、e to permit a person in the container to exit when the container is padlocked on the outside. during shipping. the corner fittings. The latch shall have With the The door shall have an internal release handle The handle and latch shall be protected from damage The handle and latch shall not extend b
24、eyond . 3.2.7 Jnter ior licrht . The container shall have a vapor proof lighting fixture mounted on the interior and a recessed or protected vapor proof switch located near door on the exterior of container. The fixture shall have a protective cover which is shatterproof and removable without tools
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILPRF44015A1997REFRIGERATORCONTAINERFIELD8FEETBY8FEETBY10FEET8 英尺 10 野外 冷藏 集装箱 PDF

链接地址:http://www.mydoc123.com/p-447245.html