1、MIL-P-445LA 12 7997706 0320565 7 MIL-P-48451A(MU) 31 December 1975 SUPERSEDING 25 January 1974 MIL-P-48451 (MU) MILITARY SPECIFICATION PERISCOPE, TANK: M36E1 This specification is approved for use by all Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 This specification covers on
2、e type of combination passive - day- light tank commanders periscope designated Periscope, Tank: M36E1. The periscope is a part of the fire control system in the 105MM Gun Tank, M60 Series and is used for observation and machine gun sighting. 2, APPLICABLE DOCUMENTS 2.1 The following documents, of t
3、he issue in effect on date of invi- tation for bids or request for proposal, form a part of this specification to the extent specified herein. SPECIFICATIONS Military MIL-F- 139 2 6 MIL-P-14232 MIL-B-14837 MIL-H-14844 MIL-1-45607 MIL-E-484 41 STANDARDS Military MIL-STD-105 MIL-STD-109 Fire Control M
4、ateriel, General Speci- f ication Governing the Manufacture and Inspection of Parts, Equipment and Tools for Army Material, Packaging and Packing of Body (Daylight) Assembly: 8619920 Head Assembly: 8619900 Inspection Equipment, Acquisition, Elbow Assembly, Passive: 11733401 Maintenance and Dispositi
5、on of Sampling Procedures and Tables for Quality Assurance Terns and Definitions Inspection by Attributes FSC 1240 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIIrP-4 8 4 5lA (MU) DRAWINGS U.S. Amy, Frankford Arsenal (28591108 F11727460 F11732167
6、 FU732168 FU746743 Torque Adapter, Elevation Input Arm Periscope, Tank: M36E1 Gage, Interchangeability, Maximum Gage, Interchangeability, Minimuni Final Acceptance Inspection Test Equipment and Arrangement Drawing PACKAGING DATA SHEET PS11727460 Packaging of Periscope, Tank: M36E1 (Copies of specifi
7、cations, standards, drawings and packaging data sheets required by suppliers in connection with specific procurement functions should be obtained from the procuring activity or as directed by the contracting officer.) 3. REQUIREMENTS 3.1 Fabrication.- The periscope shall be manufactured in accordanc
8、e with Drawing F11727460 and drawings pertaining thereto. shall have met their respective specifications (except that they need not be subjected to separate temperature and vibration tests) and be in- terchangeable within the requirements of this specification. The following Body (Daylight Assembly
9、8619920 Head Assembly 8619900 Elbow Assembly, Passive 11733401 MIL-B-14837 MIL-H-14844 MIL-E- 4 844 1 3.2 Interchangeability. a. Modules.- The periscope shall meet the requirements of 3.8.2, 3.8.5, 3-8.6 and 3.8.8 without need for realignment of components or se- lection of modules listed in 3.1. he
10、rein, are prohibited, Adjustments, other than those specified b. Periscope with mount.- The periscope shall be capable of After insertion, the periscope shall be capable of insertion into the Mount Periscope: Ml19 (gages are specified in lieu of mount in 4.6.7.2). being firmly secured and subsequent
11、ly removed. 3.3 General specification.- The contractor shall be responsible for adherence to, and compliance with the following requirements of MIL-F-13926. a. Order of precedence b. Dimensions and tolerances ci Inorganic protective surface finishes d. Part identification and marking e. Workmanship
12、2 D - . Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- MIL-P-Lt8451A 12 m 7777706 0320567 2 m 3.4 Environmental. 3.4.1 Storage temperature.- The periscope shall show no evidence of cement separation, glass breakage or other physical failure, and sh
13、all meet all the requirements of this specification at standard ambient temperature, plus 60“ to plus 90“ Fahrenheit (F), after having been exposed and ther- mally stabilized at temperatures of minus 80“ and plus 160F. 3.4.2 Operating temperatures.- The periscope shall meet the applicable requiremen
14、ts of 3.5 while exposed and thermally stabilized at temperatures of minus 40“ and plus 150F. 3.5 Operability. 3.5.1 Elevation input shaft.- The running torque required to rotate the elevation input shaft through maximum elevation and depression, shall not exceed 10 pound-inches (lb-ins) at standard
15、ambient temperature or 13 lb-ins at extreme temperatures of minus 40“ and plus 150F. 3.5.2 Diopter movement- Daylight and Passive.- The running torque required to rotate the daylight diopter movement through a minimum range of minus 3.0 to plus 3.0 diopters and the passive diopter movement through a
16、 minimum range of minus 4.0.to plus 4.0 diopters shall be within the limits of 1.5 and 6.0 lb-ins when checked at standard ambient temperature. checked at the temperature conditions specified in 3.4.2, the running torque shall not exceed 15 lb-ins. When 3.5.3 Focusing mechanism - Passive.- The runni
17、ng torque required to rotate Ring 11733436 through the range specified in 3.8.7 shall be within the limits of 4.0 and 14.0 lb-ins when checked at standard ambient tempera- ture. When checked at the temperature conditions specified in 3.4.2, the running torque shall not exceed 24.0 lb-ins. 3.5.4 Dise
18、ngagement of boresight knob locks - Daylight and Passive.- The direct force required to disengage each boresight knob from the lock position shall be within the limits of 2.0 to 5.0 pounds (lbs) when checked at standard ambient temperature. When checked at the temperature condi- tions specified in 3
19、.4.2, the direct force shall not exceed 9.0 lbs. 3.5.5 Rotation of boresight knobs - Daylight and Passive.- The runn- ing torque required to rotate each boresight knob through the travel range specified in 3.8.3.1.1 and 3.8.3.1.2 respectively, shall be within the limits of 0.5 and 5.0 lb-ins when ch
20、ecked at standard ambient temperature. When checked at the temperature conditions specified in 3.4.2 the running torque shall not exceed 8.0 lb-ins. 3.5.6 Shutter lever and on-off switch - Passive.- The torque required to rotate the shutter lever from the off to on position shall be within the limit
21、s of 4.5 to 6.5 lb-ins when checked at standard ambient temperature. When checked at temperature conditions specified in 3.4.2, the torque shall not exceed 10 lb-ins. 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-3.5.7 Gain adjust and reticle bri
22、ghtness control - Passive.- This requirement shall be met at standard ambient temperature and the tempera- ture conditions specified in 3.4.2. operable through the full limits of the rheostat. Knobs MS 91528-OE1B shall be manually 3.6 Vibration.- This requirement shall be met with the image inten- s
23、ifier tube and reticle projector lamp energized by the application of +24 -i- 6.0 MC to Contact 11733497 (Reference Drawing F11733401). The periscope shall be vibrated in a vertical plane at a constant frequency of 30 cycles per second (cps) with an amplitude of 1/6 inch (1/8 inch totalexcursion) fo
24、r a period of 5 minutes plus or minus 15 seconds. There shall be no failure or flicker of light emission from the image intensifier tube nor the reticle projector lamp during vibration and the periscope shall show no evidence of physical failure subsequent to vibra- tion. Following the vibration tes
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILP48451A1975PERISCOPETANKM36E1M36E1 坦克 潜望镜 PDF

链接地址:http://www.mydoc123.com/p-446396.html