1、 MIL-L-43615A 35 9777706 0247118 L m I MIL-L-43615A ! i 24 June 1975 SUPERSEDING MIL-L-43615 27 December 1968 MILITARY SPECIFICATION LAUNDRY PRESS UNITS, COAT, TWO-OPERATOR This specification is approved for use by all Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This s
2、peFification covers laundry presses for finishing of laundered coats when used as a unit by two operators. * 1.2 Classification. The coat laundry presses covered by this specification shall be of the following types, styles and combination units as specified (see 6.2). -0 Type I - Press, pneumatic,
3、collar and lapel Type II Press, pneumatic, cabinet type, sleeve Type III - Press, pneumatic, cabinet type, bosom, body, and yoke Style A - Single buck Style B - Double buck Combination Unit No. 1 - Type, style and quantity required Type I .- one Type 11 - one Type III, style A - two Combination Unit
4、 No. 2 - Type, style and quantity required Type I - one .Type II - one Type III, style B - one FSC 3510 ipi DOCUMENT CONTAINS ESZ PAGES 6 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-L-4 36 15A 2. APPLICABLE DOCUMENTS * 2.1 The following docum
5、ents, of the issue in effect on date of invitation for bids or request for proposal, form a part of this specification to the extent specified herein: SPECIFICATIONS FEDERAZI CC-M-636 - Lator, ALernating-Current , (Fract,onal Horsepower) CC-M-641 QQ-C-390 QQ-N-2 81 QQ-N-2 88 MILITARY MIL-T-152 MIL-L
6、-3153 STANDARDS FEDERAL FED-STD-5 95 - Motor, Alternating-Current , (Integral Horsepower, . - - Nickel-Copper-Alloy Bar, Plate, Rod, Sheet, Strip, 200 HI? and Smaller) Copper Alloy Castings (Including Cast Bar) Wire, Forgings, and Structural and Special Shaped Sections Castings - Nickel-Copper Alloy
7、 and Nickel-Copper-Silicon Alloy - Treatment, Moisture-and-Fungus-Resistant, of Communications, Electronic, and Associated Elec- trical Equipment - Laundry and Dry Cleaning Machinery-and Equipment. (For Fixed Installations), Preparation for Delivery of - Colors MILITARY MIL-STD-105 MIL-STD-130 MIL-S
8、TD-461 MIL-STD-462 - - - Electromagnetic Interference Characteristics - Electromagnetic Interference Characteristics, Sampling Procedures and Tables for Inspection by Identification Marking of U.S. Military Property Attributes r Requirements for Equipment Measurement Of (Copies of specifications and
9、 standards required by suppliers in connection with specific procurement functions should be obtained from the procuring activity or as directed by the contracting officer.) 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-I MIL-L-43615A 35 W 797970
10、6 0247320 T W MIL-L-43615A * 2.2 Other publications. The following documents form a part of this specification to the extent specified herein. Unless a specific issue is identified, the issue in effect on date of invitation for bids or request for proposal shall apply: National Electrical Manufactur
11、ers Association Standards (NEMA) Publication No. IC1-1965 - Industrial Controls (Application for copies shmld be addressed to the National Electrical Underwriters Laboratories, Inc. (UL) UL Standard 508 - Industrial Controls (Application for copies should be addressed to the Underwriters Labora- Man
12、ufacturers Association, 155 East 44th Street, New York, Ny 10017.) tories, Inc., 207 East Ohio Street, Chicago, IL Road, Melville, Long Island, NY 11746; or 1655 Scott Boulevard, Santa Clara, CA 95050.) 60611; 1285 Walt Whitman National Fire Protection Association (NFPA) “PA Standard No. 70 - The Na
13、tional Electrical Code (Application for copies should be addressed to the National Fire Protection Association, 60 Batterymarch Street, Boston, MA 02110.) American Society of Mechanical Engineers Code (ASME) Boiler and Preseure Vessel Code, Section VIII, Unfired Pressure Vessels Welding Qualificatio
14、ns of the American Society of Mechanical Engineers (Application for copies should be addressed to the American Society of Mechanical Engineers, 345 East 45th Street, New York, -W. 10017.) American Society for Testing and Materials (ASTM) - - A 162 - Corrosion-Resisting Chromium-Nickel Steel Plate, A
15、 176 - Stainless and Heat-Resisting Chromium Steel Plate, Sheet, and Strip Sheet, and Strip (Application for copies should be addressed to the American Society for Testing and Materiais, 1916 Race Street, Philadelphia, PA 19103. ) Provided by IHSNot for ResaleNo reproduction or networking permitted
16、without license from IHS-,-,-MIL-L-Y3bL5A 35 I 9999906 0249L2L L = - MIL-L-43615.4 (Technical society and technical association specifications and standards are generally available for reference from libraries. buted among technical groups and using Federal agencies.) They are also distri- 3. REQUIR
17、EMENTS * 3.1 Standard product. The laundry presses delivered under this specification shall be the manufacturers commercial product, except for any changes necessary to canply with the specification requirements. one contract, including parts and subassemblies thereof, shall be new and interchangeab
18、le. All like items furnished on any 3.2 Codes and standards. * 3.2.1 - NFPA. The installation of the electrical components and wiring of the laundry press shall conform to NFPA Standard No. 70. 3.2.2 E. UL Standard No. 508 for use in ordinary locations, Electrical controls of the laundry prese shall
19、 conform to * 3.2.3 NEMA. Motor controllers shall conform to performance requirements of NEMA Standards Publication No. IC1-1965. 3.2.4 ASME. All chests, cylinders, and chambers containing steam shall be fabricated and tested in accordance with the ASME code for unfired press- ure vessels. * 3.3 Cer
20、tification. Prior to approval of the preproduction sample, or if none is submitted, prior to approval of the first shipment, the supplier shall submit satisfactory evidence to the contracting officer or his authorized representative, that the laundry press or electrical components he proposes to fur
21、nish meet the requirements specified in 3.2.1, 3.2.2, 3.2.3 and 3.2.4, 88 applicable. 3.3.1 NFPA. Acceptable evidence of meeting requirements of 3.2.1 shall be the manufacturers certified statement that the aundry press conforms to “A Standard No. 70. 3.3.2 E. Acceptable evidence of meeting requirem
22、ents of 3.2.2 shall be the UL label or a UL listing of the laundry press or the electrical components, or certification from an independent testing laboratory acceptable to the contracting officer or his authorized representative that tlle laundry press or electrical components conform to applicable
23、 UL Standarde. 3.3.3 “A. Acceptable evidence of meeting the requirements of 3.2.3. ohall be the manufacturers certif led statement that the -tor. controllers amform to NEM Standard Publication No. IC1-1965. A tag or label attached to the controllerb) stating the component conforms.to this standard i
24、s acceptable evidence. - Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-n ik I * * (. * * I MIL-L-LI3bL5A 35 9999906 0249122 3 = MIL-L-4 36k5A 3.3.4 - ASME. Acceptable evidence of meeting the requirements of 3.2.4 . shall be a written certificate st
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILL43615A1975LAUNDRYPRESSUNITSCOATTWOOPERATOR 操作 大衣 烫衣 元件 PDF

链接地址:http://www.mydoc123.com/p-445540.html