ARMY A-A-52429 A-2009 VALVE SOLENOID OPERATED [Replaced ARMY MIL-V-62381 A CANC NOTICE 1 ARMY MIL-V-62381 A ARMY MIL-V-62381]《电磁控制阀[代替 ARMY MIL-V-62381 A CANC NOTICE 1 ARMY MIL-V-6.pdf
《ARMY A-A-52429 A-2009 VALVE SOLENOID OPERATED [Replaced ARMY MIL-V-62381 A CANC NOTICE 1 ARMY MIL-V-62381 A ARMY MIL-V-62381]《电磁控制阀[代替 ARMY MIL-V-62381 A CANC NOTICE 1 ARMY MIL-V-6.pdf》由会员分享,可在线阅读,更多相关《ARMY A-A-52429 A-2009 VALVE SOLENOID OPERATED [Replaced ARMY MIL-V-62381 A CANC NOTICE 1 ARMY MIL-V-62381 A ARMY MIL-V-62381]《电磁控制阀[代替 ARMY MIL-V-62381 A CANC NOTICE 1 ARMY MIL-V-6.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Comments, suggestions, or questions on this document should be addressed to U.S. Army Tank-automotive and Armaments Command, ATTN: RDTA-EN/STND/TRANS, MS# 268, 6501 E. 11 Mile Road, Warren, MI 48397-5000 or emailed to DAMI_STANDARDIZATIONconus.army.mil. Since contact information can change, you may
2、want to verify the currency of this address information using the ASSIST Online database at http:/assist.daps.dla.mil. AMSC N/A FSC 4810 INCH-POUND A-A-52429A(AT) September 8, 2009 SUPERSEDES A-A-52429(AT) 15 February 1993 COMMERCIAL ITEM DESCRIPTION VALVE, SOLENOID OPERATED The General Services Adm
3、inistration has authorized the use of this commercial item description (CID) as a replacement for MIL-V-62381A(AT) which is cancelled. 1. SCOPE. This CID establishes the requirements for a direct acting, poppet style, two-way shutoff solenoid operated valve for use on a military ground vehicle elect
4、ronic drive system as an emergency bypass valve. 2. SALIENT CHARACTERISTICS. 2.1 Materials. Materials shall be as specified herein. It shall be free from defects which adversely affect its performance or serviceability. The use of recovered material made in compliance with regulatory requirements is
5、 acceptable providing that all requirements of this CID are met (see 5.5). 2.1.1 Material compatibility. Materials for the solenoid valve shall be compatible with the hydraulic fluid, petroleum or synthetic base, used to inhibit corrosion, improve the low-temperature flow, viscosity characteristics
6、and resistance to oxidation of the valve. 2.1.2 Age-sensitive materials. Age control of the valve assembly should be based on the cure date of the oldest elastomeric component. The maximum age of the elastomeric item at time of acceptance by the Government shall not exceed 32 quarters for hoses and
7、40 quarters for O-rings (see 2.12.1). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-52429A(AT) 2 2.1.3 Metals. Metals shall be corrosion resistant or suitably treated to prevent corrosion. The use of dissimilar metals, especially brass, copper,
8、 or steel in intimate metal to metal contact, shall be avoided. 2.2 Design and construction. The solenoid valve shall be a direct acting, poppet style shutoff valve, normally closed. The solenoid must be energized for the valve to remain open and allow flow of fluid. The solenoid valve shall conform
9、 to Drawing 12265543 and other applicable drawings, specifications and standards (see 5.2). 2.2.1 Operating fluid. The valve shall operate satisfactorily with hydraulic fluid (see 2.1.1). 2.3 Performance. 2.3.1 Proof pressure. With outlet port plugged, a pressure to the inlet port at a rate of 25,00
10、0 pounds per square inch (psi) per minute is applied until a pressure of 4,500 psi is obtained. The valve shall withstand this pressure for a period of 2 minutes without permanent deformation, rupture, or measurable external leakage. 2.3.2 Burst pressure. With outlet port plugged, a pressure to the
11、inlet port at a rate of 25,000 psi per minute is applied until a pressure of 7,500 psi is obtained. The valve shall withstand this burst pressure for a period of 2 minutes without rupture of internal or external parts. Solenoid valves subjected to this test shall be indelibly marked as damaged and s
12、hall not be delivered as acceptable units. 2.3.3 Pull-in voltage. With the inlet at a maximum operating pressure and with the discharge restricted to maintain rated flow, the valve shall actuate at any voltage applied to the solenoid within a range between 18 and 30 volts direct current (Vdc). 2.3.4
13、 Hold-in voltage. When energized with greater than 24 Vdc at maximum operating pressure and the discharge restricted to maintain flow, the valve shall not release at any voltage to the solenoid greater than 16 Vdc. 2.3.5 Coil current. With solenoid activated, the actuating current shall not exceed 0
14、.625 ampere (A) dc at 30 Vdc and at 77 degrees Fahrenheit (F). 2.3.6 Insulation resistance. With 500 Vdc applied between the coil terminals connected together and the case, there shall be at least 100 megohms of resistance. 2.3.7 Dielectric withstanding voltage. The solenoid valve shall be capable o
15、f initially withstanding 500 V root mean square (rms), 60 Hertz (Hz) for 1 minute between terminals tied together and the case. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-52429A 3 2.3.8 Voltage transient. The valve shall perform as specified
16、 when subjected to transient voltages as specified in MIL-STD-1275. 2.3.9 Rated flow. The flow capacity of the valve shall be not less than 0.25 gallon per minute (gpm), inlet to outlet, with a pressure drop across the valve of 75 psi. 2.3.10 Internal leakage. With the solenoid de-energized and the
17、valve closed, a pressure of 3000 psi shall be applied to the inlet port and held for 2 minutes; the internal leakage at the outlet shall not exceed 0.25 ml after 2 minutes. 2.3.11 External leakage. There shall be no evidence of leakage through external seals. Verification is done by visual examinati
18、ons. 2.3.12 Operating time. The units shall open in not more than 1 second by establishing flow at a rate of 0.25 gpm at 3000 psi after the solenoid shown in drawing 12265543 test circuit has been energized. 2.3.13 Closing time. The units shall close in not more than 1 second by terminating flow aft
19、er the solenoid shown in drawing 12265543 test circuit has been de-energized. 2.4 High temperature. The solenoid valve shall operate when subjected to a high ambient temperature of 140F. The valve unit shall not be damaged nor its performance impaired after storage in a non-operating mode at a high
20、ambient temperature of 158F. 2.5 Low temperature. The solenoid valve shall operate when subjected to a low ambient temperature of minus (-) 26F. The valve unit shall not be damaged nor its performance impaired after storage in a non-operating mode at a low ambient temperature of -65F. 2.6 Hydraulic
21、fluid temperature. The solenoid valve shall operate using hydraulic oil in accordance with 2.1.1 at operating oil temperatures of -26F to 170F with ambient air conditions as specified in 2.4 and 2.5. 2.7 Shock (non-operating). The units shall operate after exposure to a shock impulse of 25 gravity u
22、nits (g) for 11 milliseconds (ms), half-sine wave form. 2.8 Vibration (non-operating). The valve shall meet the performance requirements and show no evidence of failure or damage after performance of a vibration test in accordance with 2.8.1 and 2.8.2. 2.8.1 Low frequency. The valve shall be subject
23、ed to a simple harmonic motion having an amplitude of 0.03 inch (in.) (0.06 in. maximum total excursion) with the frequency being varied uniformly between the approximate limits of 10 to 55 Hertz (Hz). The entire frequency range, Provided by IHSNot for ResaleNo reproduction or networking permitted w
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYAA52429A2009VALVESOLENOIDOPERATEDREPLACEDARMYMILV62381ACANCNOTICE1ARMYMILV62381AARMYMILV62381 电磁

链接地址:http://www.mydoc123.com/p-439962.html