ANSI UL 391-2010 UL Standard for Safety Solid-Fuel and Combination-Fuel Central and Supplementary Furnaces (Fifth Edition Reprint with Revisions Through and Including June 12 2014).pdf
《ANSI UL 391-2010 UL Standard for Safety Solid-Fuel and Combination-Fuel Central and Supplementary Furnaces (Fifth Edition Reprint with Revisions Through and Including June 12 2014).pdf》由会员分享,可在线阅读,更多相关《ANSI UL 391-2010 UL Standard for Safety Solid-Fuel and Combination-Fuel Central and Supplementary Furnaces (Fifth Edition Reprint with Revisions Through and Including June 12 2014).pdf(102页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 391 Solid-Fuel and Combination-Fuel Central and Supplementary FurnacesUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED
2、 MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Solid-Fuel and Combination-Fuel Central and Supplementary Furnaces, UL 391 Fifth Edition, Dated September 10, 2010 Summary of Topics This revision of ANSI/UL 391 is being issued to
3、 update the title page to reect reaffirmation of ANSI approval. Text that has been changed in any manner or impacted by ULs electronic publishing system is marked with a vertical line in the margin. Changes in requirements are marked with a vertical line in the margin and are followed by an effectiv
4、e date note indicating the date of publication or the date on which the changed requirement becomes effective. The revised requirements are substantially in accordance with Proposal(s) on this subject dated April 25, 2014. All rights reserved. No part of this publication may be reproduced, stored in
5、 a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties o
6、f merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or
7、an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnif
8、y, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. The requirements in this Stand
9、ard are now in effect, except for those paragraphs, sections, tables, gures, and/or other elements of the Standard having future effective dates as indicated in the note following the affected item. The prior text for requirements that have been revised and that have a future effective date are loca
10、ted after the Standard, and are preceded by a SUPERSEDED REQUIREMENTS notice. JUNE 12, 2014 UL 391 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL JUNE 12, 2014 UL 391 tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FUR
11、THER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL SEPTEMBER 10, 2010 (Title Page Reprinted: June 12, 2014) 1 UL 391 Standard for Solid-Fuel and Combination-Fuel Central and Supplementary Furnaces First Edition July, 1981 Second Edition August, 1991 Third Edition April, 1995 Fourth Edition
12、 October, 2006 Fifth Edition September 10, 2010 This ANSI/UL Standard for Safety consists of the Fifth edition including revisions through June 12, 2014. The most recent designation of ANSI/UL 391 as a Reaffirmed American National Standard (ANS) occurred on June 12, 2014. ANSI approval for a standar
13、d does not include the Cover Page, Transmittal Pages, Title Page, or effective date information. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development
14、 System (CSDS) at http:/. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. CO
15、PYRIGHT 2014 UNDERWRITERS LABORATORIES INC. ANSI/UL 391-2006 (R2014)UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL SEPTEMBER 10, 2010 UL 391 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTI
16、ON WITHOUT PERMISSION FROM UL CONTENTS INTRODUCTION 1 Scope .6 2 Components 6 3 Units of Measurement .7 4 Undated References 7 5 Glossary .7 CONSTRUCTION 6 General 9 7 Accessibility for Servicing .12 8 Protection of Users and Service Personnel 12 9 Base .15 10 Casings .16 11 Radiation Shields or Lin
17、ers 17 12 Materials in Air-Handling Compartments .17 13 Air Filters 18 14 Combustion Chambers 18 15 Radiators 18 16 Heating Surface Joints 18 17 Baffles.19 18 Flue Collars 20 19 Disposal of Combustion Products .20 20 Dampers, Shutters and Draft Regulators .20 21 Electrical Enclosures 20 21.1 General
18、 .20 21.2 Doors and covers 24 21.3 Field wiring system connections 25 22 Accessibility of Uninsulated Live Parts, Film-Coated Wire and Moving Parts .26 FIELD WIRING 23 General 32 24 Leads and Terminals 34 INTERNAL WIRING 25 General 35 26 Methods .36 27 Short-Circuit Protection 39 28 Separation of Ci
19、rcuits .39 29 Bonding for Grounding 41 ELECTRICAL COMPONENTS 30 General .44 31 Mounting of Electrical Components .45 32 Electrical Insulating Material 46 33 Capacitors .46 SEPTEMBER 10, 2010 UL 391 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FR
20、OM UL 34 Receptacles 46 35 Motors and Motor (Overload) Protection .47 36 Safety Controls and Circuits 52 36.1 General .52 36.2 Fan, limit, and thermostatic damper controls .52 36.3 Supplementary central furnace controls .53 36.4 Primary safety control .53 37 Switches and Controllers 54 SPACINGS 38 H
21、igh-Voltage Circuits 55 39 Low-Voltage Circuits 56 PERFORMANCE 40 General 56 TEST INSTALLATION FOR CENTRAL FURNACES 41 Enclosure 57 42 Chimney Connector .58 43 Supply-and Return-Air Plenums and Ducts Forced-Air Furnace .61 TEST INSTALLATION FOR SUPPLEMENTARY CENTRAL FURNACES 44 General 62 INSTRUMENT
22、ATION 45 Draft 62 46 Fuel Input 63 47 Power Measurement 63 48 Speed Measurement 63 49 Static Pressure .63 50 Temperature Measurement 65 INITIAL TEST CONDITIONS 51 General 68 52 Static Pressures for Tests .69 53 Solid Fuels and Test Firing Procedures 69 53.1 General .69 53.2 Firebrands .69 53.3 Charc
23、oal 72 INITIAL TESTS 54 Combustion Test Oil Burner and Furnace 72 55 Operation Test .73 56 Limit Control Cutout Test 74 56.1 General .74 56.2 Combination oil-red and solid-fuel-red central furnaces 74 SEPTEMBER 10, 2010 UL 391 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTR
24、IBUTION WITHOUT PERMISSION FROM UL 56.3 Solid-fuel-red central furnaces 75 56.4 Supplementary central furnaces 76 TEMPERATURE TESTS 57 General 76 58 Continuous Operation Test .80 58.1 General .80 58.2 Continuous operation .81 58.3 Loss of electrical power .81 58.4 Simultaneous ring .82 59 Air Flow R
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIUL3912010ULSTANDARDFORSAFETYSOLIDFUELANDCOMBINATIONFUELCENTRALANDSUPPLEMENTARYFURNACESFIFTHEDITIONREPRINTWITHREVISIONSTHROUGHANDINCLUDINGJUNE122014PDF

链接地址:http://www.mydoc123.com/p-439200.html