《ANSI UL 1561-2011 UL Standard for Safety Dry-Type General Purpose and Power Transformers (Fourth Edition Reprint with Revisions Through and Including June 16 2015)《干式通用和电力变压器安全性标准》.pdf》由会员分享,可在线阅读,更多相关《ANSI UL 1561-2011 UL Standard for Safety Dry-Type General Purpose and Power Transformers (Fourth Edition Reprint with Revisions Through and Including June 16 2015)《干式通用和电力变压器安全性标准》.pdf(64页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 1561 Dry-Type General Purpose and Power TransformersUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL NOT AUTH
2、ORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Dry-Type General Purpose and Power Transformers, UL 1561 Fourth Edition, Dated March 2, 2011 Summary of Topics This revision of ANSI/UL 1561 incorporates the following change: Addition of Overload T
3、est Requirements for Class 240 Insulation Systems The effective date for UL LLC will be announced through Industry File Review Announcement Letter. The new requirements are substantially in accordance with Proposal(s) on this subject dated March 20, 2015. Text that has been changed in any manner or
4、impacted by ULs electronic publishing system is marked with a vertical line in the margin. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without p
5、rior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or si
6、milar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liability for any damage e
7、ver exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fe
8、es) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. JUNE 16, 2015 UL 1561 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL JUNE 16, 2015 UL 1561 tr2 No T
9、ext on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL MARCH 2, 2011 (Title Page Reprinted: June 16, 2015) 1 UL 1561 Standard for Dry-Type General Purpose and Power Transformers Prior to the rst edition, the requirements for the pro
10、ducts covered by this standard were included in a supplement to the Standard for Specialty Transformers, UL 506. Prior to March 27, 1987, the rst edition was titled the Standard for Large General Purpose Transformers. First Edition January, 1986 Second Edition April, 1994 Third Edition March, 1999 F
11、ourth Edition March 2, 2011 This ANSI/UL Standard for Safety consists of the Fourth Edition including revisions through June 16, 2015. The most recent designation of ANSI/UL 1561 as an American National Standard (ANSI) occurred on June 16, 2015. ANSI approval for a standard does not include the Cove
12、r Page, Transmittal Pages and Title Page. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at http:/. ULs Standards for Safety are
13、copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. COPYRIGHT 2015 UNDERWRITERS LABORATORIES INC. ANSI/UL 156
14、1-2015UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL MARCH 2, 2011 DRY-TYPE GENERAL PURPOSE AND POWER TRANSFORMERS - UL 1561 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMI
15、SSION FROM UL CONTENTS INTRODUCTION 1 Scope .5 2 Components 5 3 Units of Measurement .6 4 Undated References 6 5 Glossary .6 CONSTRUCTION 6 Mechanical Assembly .7 7 Enclosure 8 7.1 General .8 7.2 Sheet metal 8 7.3 Nonmetallic enclosures 9 7.4 Mounting .10 7.5 Covers .10 7.6 Ventilation 10 7.7 Specic
16、 environmental conditions .11 7.8 Corrosion protection .13 8 Corrosion Resistance .13 9 Supply and Load Connections .15 10 Field Wiring Connections 16 10.1 General .16 10.2 Leads .16 10.3 Pressure terminal connectors 17 11 Current-Carrying Parts 18 12 Electrical Insulation .20 13 Internal Wiring 20
17、14 Coil Insulation 21 15 Coil Details 21 16 Electrical Spacings 21 17 Insulating Barriers 25 18 Transient Voltage Surge Suppressors .26 19 Capacitors .26 20 Surge Arresters .26 PERFORMANCE 21 General 26 22 Impedance Test 28 23 Temperature Test .28 23.1 General .28 23.2 Units for wall mounting 33 23.
18、3 Units for oor mounting .34 23.4 Clamped bus joint 35 24 Dielectric Voltage-Withstand Test .35 24.1 Applied potential .35 24.2 Induced potential .36 25 Overload Test 37 MARCH 2, 2011 DRY-TYPE GENERAL PURPOSE AND POWER TRANSFORMERS - UL 1561 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPROD
19、UCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 26 Dielectric Voltage-Withstand Test Repeated 37 27 Lifting or Mounting Means Test .38 28 Enclosure Strength Tests 39 28.1 Deection test .39 28.2 Compression test .39 29 Clamped Insulating Joint and Insulating Barrier Tests .39 30 Water Spray Test .4
20、0 31 Drip Test 43 32 Icing Test 43 33 Rust Resistance Test .44 34 Corrosion Resistance Test .44 35 Metallic Coating Thickness Test 44 36 Production-Line Dielectric Voltage-Withstand Test 46 RATINGS 37 General 47 MARKINGS 38 Details .50 38.1 General .50 38.2 Nonsinusoidal load ratings .50 38.3 Insula
21、tion temperature class .51 38.4 Temperature rise .51 38.5 Temperature sensor 51 38.6 Ambient temperature .51 38.7 Autotransformer, elevated voltage (buck or boost) 51 38.8 Impedance 52 38.9 Environmental condition enclosures 52 38.10 Mounting .52 38.11 Weight .53 38.12 Field wiring .53 39 Permanence
22、 of Marking .54 APPENDIX A Standards for ComponentsA1 MARCH 2, 2011 DRY-TYPE GENERAL PURPOSE AND POWER TRANSFORMERS - UL 1561 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL INTRODUCTION 1 Scope 1.1 These requirements cover: a) General purp
23、ose and power transformers of the air-cooled, dry, ventilated, and nonventilated types to be used in accordance with the National Electrical Code, ANSI/NFPA 70. Constructions include step up, step down, insulating, and autotransformer type transformers as well as air- cooled and dry-type reactors or
24、 b) General purpose and power transformers of the exposed core, air-cooled, dry, and compound-lled types rated more than 10 kVA to be used in accordance with the National Electrical Code, ANSI/NFPA 70. Constructions include step up, step down, insulating, and autotransformer type transformers as wel
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIUL15612011ULSTANDARDFORSAFETYDRYTYPEGENERALPURPOSEANDPOWERTRANSFORMERSFOURTHEDITIONREPRINTWITHREVISIONSTHROUGHANDINCLUDINGJUNE162015

链接地址:http://www.mydoc123.com/p-438918.html