1、 TIA/EIA STANDARD Commercial Building Telecommunications Cabling Standard Part 1: General Requirements TIA/EIA-568-B.1 (Revision of TIA/EIA-568-A) MAY 2001 TELECOMMUNICATIONS INDUSTRY ASSOCIATION The Telecommunications Industry Association represents the communications sector of ANSI/TIA/EIA-568-B.1
2、-2001 Approved: April 12, 2001 TIA/EIA-568-B.1Copyright Electronic Industries Alliance Provided by IHS under license with EIANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-NOTICE TIA/EIA Engineering Standards and Publications are designed to serve the public inter
3、est through eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for his particular need. Existence of such Standards and Publicati
4、ons shall not in any respect preclude any member or nonmember of TIA/EIA from manufacturing or selling products not conforming to such Standards and Publications, nor shall the existence of such Standards and Publications preclude their voluntary use by those other than TIA/EIA members, whether the
5、standard is to be used either domestically or internationally. Standards and Publications are adopted by TIA/EIA in accordance with the American National Standards Institute (ANSI) patent policy. By such action, TIA/EIA does not assume any liability to any patent owner, nor does it assume any obliga
6、tion whatever to parties adopting the Standard or Publication. This Standard does not purport to address all safety problems associated with its use or all applicable regulatory requirements. It is the responsibility of the user of this Standard to establish appropriate safety and health practices a
7、nd to determine the applicability of regulatory limitations before its use. (From Standards Proposal Nos.4425-B, 4425-B-1 and 4425-B-2, formulated under the cognizance of the TIA TR-42 Committee on User Premises Telecommunications Infrastructure.) Published by TELECOMMUNICATIONS INDUSTRY ASSOCIATION
8、 2001 Standards and Technology Department 2500 Wilson Boulevard Arlington, VA 22201 PRICE: Please refer to current Catalog of EIA ELECTRONIC INDUSTRIES ALLIANCE STANDARDS and ENGINEERING PUBLICATIONS or call Global Engineering Documents, USA and Canada (1-800-854-7179) International (303-397-7956) A
9、ll rights reserved Printed in U.S.A. Copyright Electronic Industries Alliance Provided by IHS under license with EIANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-PLEASE! DONT VIOLATE THE LAW! This document is copyrighted by the TIA and may not be reproduced witho
10、ut permission. Organizations may obtain permission to reproduce a limited number of copies through entering into a license agreement. For information, contact: Global Engineering Documents 15 Inverness Way East Englewood, CO 80112-5704 or call U.S.A. and Canada 1-800-854-7179, International (303) 39
11、7-7956 Copyright Electronic Industries Alliance Provided by IHS under license with EIANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Copyright Electronic Industries Alliance Provided by IHS under license with EIANot for ResaleNo reproduction or networking permitte
12、d without license from IHS-,-,-TIA/EIA-568-B.1 i Commercial Building Telecommunications Cabling Standard; Part 1: General Requirements Table of Contents FOREWORD .vi 1 INTRODUCTION 1 1.1 Purpose 1 1.2 Specification of criteria1 1.3 Metric equivalents of US customary units .1 1.4 Life of this Standar
13、d1 1.5 Telecommunications cabling system structure2 2 Scope. 4 2.1 Normative references 4 3 DEFINITION OF TERMS, ACRONYMS AND ABBREVIATIONS, AND UNITS OF MEASURE 6 3.1 General .6 3.2 Definition of terms 6 3.3 Acronyms and abbreviations11 3.4 Units of measure12 4 HORIZONTAL CABLING 14 4.1 General .14
14、 4.2 Topology .14 4.3 Horizontal distances .15 4.4 Recognized cables .16 4.5 Choosing types of cabling .16 4.6 Grounding considerations17 5 BACKBONE CABLING. 18 5.1 General .18 5.2 Topology .18 5.2.1 Star topology 18 5.2.2 Accommodation of non-star configurations .19 5.2.3 Cabling directly between t
15、elecommunications rooms 19 5.3 Recognized cables .20 5.4 Choosing media .20 5.5 Backbone cabling distances21 5.5.1 Intra and interbuilding distances 21 Copyright Electronic Industries Alliance Provided by IHS under license with EIANot for ResaleNo reproduction or networking permitted without license
16、 from IHS-,-,-TIA/EIA-568-B.1 ii 5.5.2 Main cross-connect to entrance facility22 5.5.3 Cross-connections.23 5.5.4 Cabling to telecommunications equipment .23 5.6 Grounding and bonding considerations .23 6 WORK AREA. 24 6.1 General .24 6.2 Telecommunications outlet/connector 24 6.2.1 100-Ohm balanced
17、 twisted-pair telecommunications outlet/connector.24 6.2.2 Optical fiber telecommunications outlet connector 25 6.3 Work area cords 25 6.4 Open office cabling.26 6.4.1 Multi-user telecommunications outlet assembly .26 6.4.1.1 Application planning26 6.4.1.2 Installation practices .26 6.4.1.3 Administ
18、ration 27 6.4.1.4 Maximum lengths for copper cabling.27 6.4.1.5 Horizontal distances of optical fiber links (long work area cables)28 6.4.2 Consolidation point 28 6.4.2.1 Application planning28 6.4.2.2 Installation practices .29 6.4.2.3 Administration 29 7 TELECOMMUNICATIONS ROOMS. 30 7.1 General .3
19、0 7.2 Design 30 7.3 Functions 30 7.4 Cross-connections and interconnections 30 8 EQUIPMENT ROOMS 32 8.1 General .32 8.2 Design 32 8.3 Functions 32 8.4 Cabling practices .32 9 ENTRANCE FACILITIES 33 9.1 General .33 9.2 Design 33 9.3 Functions 33 9.3.1 Network demarcation point .33 9.3.2 Electrical pr
20、otection.33 9.3.3 Bonding and grounding.33 9.3.4 Entrance facility connections 33 10 CABLING INSTALLATION REQUIREMENTS 34 10.1 General34 10.1.1 Placement of horizontal and backbone cables 34 Copyright Electronic Industries Alliance Provided by IHS under license with EIANot for ResaleNo reproduction
21、or networking permitted without license from IHS-,-,-TIA/EIA-568-B.1 iii 10.2 Balanced 100-ohm twisted-pair cabling (UTP and ScTP).34 10.2.1 Minimum bend radius.34 10.2.1.1 Minimum horizontal cable bend radius 34 10.2.1.2 Minimum backbone cable bend radius 34 10.2.1.3 Minimum patch cable bend radius
22、 34 10.2.2 Maximum pulling tension34 10.2.3 Connecting hardware termination 34 10.2.4 Patch cords, equipment cords, work area cords, and jumpers .35 10.2.5 100-Ohm ScTP grounding requirements.35 10.3 Optical fiber cabling 35 10.3.1 Minimum bend radius and maximum pulling tension .35 10.3.2 Connectin
23、g hardware termination and polarity.35 10.3.3 Patch cords, equipment cords and work area cords 37 10.4 150-Ohm shielded twisted-pair cabling38 10.4.1 Minimum bend radius.38 10.4.2 Maximum pulling tension38 10.4.3 Connecting hardware termination 38 11 CABLING TRANSMISSION PERFORMANCE AND TEST REQUIRE
24、MENTS 39 11.1 General39 11.2 100-Ohm twisted-pair transmission performance and field test requirements.39 11.2.1 Purpose and scope39 11.2.2 Applicability 39 11.2.3 Test configurations 39 11.2.4 Test parameters 41 11.2.4.1 General41 11.2.4.2 Wire map.42 11.2.4.3 Length.43 11.2.4.3.1 Physical length v
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSITIAEIA568B12001COMMERCIALBUILDINGTELECOMMUNICATIONSCABLINGSTANDARD 商用 建筑物 电信 电缆 敷设 标准 PDF

链接地址:http://www.mydoc123.com/p-438287.html