《ANSI SP3.4-2012 The Protection of Electrostatic Discharge Susceptible Items - Periodic Verification of Air Ionizer Performance Using a Small Test Fixture.pdf》由会员分享,可在线阅读,更多相关《ANSI SP3.4-2012 The Protection of Electrostatic Discharge Susceptible Items - Periodic Verification of Air Ionizer Performance Using a Small Test Fixture.pdf(19页珍藏版)》请在麦多课文档分享上搜索。
1、 Reaffirmation of ANSI/ESD SP3.4-2012 For the Protection of Electrostatic Discharge Susceptible Items - Periodic Verification of Air Ionizer Performance Using a Small Test Fixture Electrostatic Discharge Association 7900 Turin Road, Bldg. 3 Rome, NY 13440 An American National Standard Approved Janua
2、ry 5, 2017ANSI/ESD SP3.4-2016 ESD Association Standard Practice for the Protection of Electrostatic Discharge Susceptible Items - Periodic Verification of Air Ionizer Performance Using a Small Test Fixture Approved September 23, 2016 ESD AssociationANSI/ESD SP3.4-2016 Electrostatic Discharge Associa
3、tion (ESDA) standards and publications are designed to serve the public interest by eliminating misunderstandings between manufacturers and purchasers, facilitating the interchangeability and improvement of products and assisting the purchaser in selecting and obtaining the proper product for his pa
4、rticular needs. The existence of such standards and publications shall not in any respect preclude any member or non-member of the Association from manufacturing or selling products not conforming to such standards and publications. Nor shall the fact that a standard or publication that is published
5、 by the Association preclude its voluntary use by non-members of the Association, whether the document is to be used either domestically or internationally. Recommended standards and publications are adopted by the ESDA in accordance with the ANSI Patent policy. Interpretation of ESDA Standards: The
6、 interpretation of standards in-so-far as it may relate to a specific product or manufacturer is a proper matter for the individual company concerned and cannot be undertaken by any person acting for the ESDA. The ESDA Standards Chairman may make comments limited to an explanation or clarification o
7、f the technical language or provisions in a standard, but not related to its application to specific products and manufacturers. No other person is authorized to comment on behalf of the ESDA on any ESDA Standard. THE CONTENTS OF ESDAS STANDARDS AND PUBLICATIONS ARE PROVIDED “AS-IS,” AND ESDA MAKES
8、NO REPRESENTATIONS OR WARRANTIES, EXPRESSED OR IMPLIED, OF ANY KIND WITH RESPECT TO SUCH CONTENTS. ESDA DISCLAIMS ALL REPRESENTATIONS AND WARRANTIES, INCLUDING WITHOUT LIMITATION, WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR USE, TITLE AND NON-INFRINGEMENT. ESDA STANDARDS AND P
9、UBLICATIONS ARE CONSIDERED TECHNICALLY SOUND AT THE TIME THEY ARE APPROVED FOR PUBLICATION. THEY ARE NOT A SUBSTITUTE FOR A PRODUCT SELLERS OR USERS OWN JUDGEMENT WITH RESPECT TO ANY PARTICULAR PRODUCT DISCUSSED, AND ESDA DOES NOT UNDERTAKE TO GUARANTEE THE PERFORMANCE OF ANY INDIVIDUAL MANUFACTURER
10、S PRODUCTS BY VIRTUE OF SUCH STANDARDS OR PUBLICATIONS. THUS, ESDA EXPRESSLY DISLAIMS ANY RESPONSIBILITY FOR DAMAGES ARISING FROM THE USE, APPLICATION, OR RELIANCE BY OTHERS ON THE INFORMATION CONTAINED IN THESE STANDARDS OR PUBLICATIONS. NEITHER ESDA, NOR ITS MEMBERS, OFFICERS, EMPLOYEES OR OTHER R
11、EPRESENTATIVES WILL BE LIABLE FOR DAMAGES ARISING OUT OF, OR IN CONNECTION WITH, THE USE OR MISUSE OF ESDA STANDARDS OR PUBLICATIONS, EVEN IF ADVISED OF THE POSSIBILITY THEREOF. THIS IS A COMPREHENSIVE LIMITATION OF LIABILITY THAT APPLIES TO ALL DAMAGES OF ANY KIND, INCLUDING WITHOUT LIMITATION, LOS
12、S OF DATA, INCOME OR PROFIT, LOSS OF OR DAMAGE TO PROPERTY AND CLAIMS OF THIRD PARTIES. Published by: Electrostatic Discharge Association 7900 Turin Road, Bldg. 3 Rome, NY 13440 Copyright 2016 by ESD Association All rights reserved No part of this publication may be reproduced in any form, in an ele
13、ctronic retrieval system or otherwise, without the prior written permission of the publisher. Printed in the United States of America ISBN: 1-58537-291-9DISCLAIMER OF WARRANTIES DISCLAIMER OF GUARANTY LIMITATION ON ESDAs LIABILITY CAUTION NOTICE ANSI/ESD SP3.4-2016 i (This foreword is not part of ES
14、D Association Standard Practice ANSI/ESD SP3.4-2016) FOREWORD Grounding of conductive and static dissipative materials, personnel, and equipment is the primary method used to limit static charge for the protection of electrostatic discharge susceptible items in the work environment. A static control
15、 program may include air or nitrogen ionization techniques to mitigate charge on isolated conductors (conductors that are not grounded), and insulating materials (e.g., most common plastics). The ionization standard test method, ANSI/ESD STM3.1, defines test methods and instrumentation, the Charged
16、Plate Monitor (CPM), for making discharge (charge neutralization) time and offset voltage (ion balance) measurements of air ionization equipment in defined environments. These standard test methods are applicable for product qualification, selecting an air ionizer for a specific application, as well
17、 as subsequently determining that the incoming product meets the selection criteria. The test instrumentation and methods of the standard test method are also usable for compliance verification of ionizer performance per ESD TR53. ANSI/ESD STM3.1 also contains additional information regarding ionize
18、r physics, ionizer measurement issues, and sources of measurement error. The user is advised to review ANSI/ESD STM3.1 before using the procedures described in this standard practice1. Detailed performance testing under laboratory conditions may be required during selection, product qualification, a
19、nd acceptance testing due to the variety of environments in which ionizers are used. Periodic and compliance verification, however, are most often performed under actual use conditions. In general, all ionizers should be tested, rather than a sampling of product types or incoming lots. Periodic veri
20、fication procedures should also be part of the initial acceptance process to provide a baseline for comparison with future measurements. Compliance verification may be necessary to meet audit requirements. The test procedures in the ionization standard ANSI/ESD STM3.1 are complete enough to be used
21、for product qualification, selection or acceptance testing, as well as for periodic verification. Additional periodic verification procedures are described in ANSI/ESD SP3.3, Periodic Verification of Air Ionizers. ANSI/ESD STM3.1 describes a measuring instrument, the CPM, which utilizes a 15 cm x 15
22、 cm (6 inch x 6 inch) isolated conductive plate assembly. ANSI/ESD SP3.3 allows for alternative instrumentation, as long as the alternative instrumentation correlates to measurements made with the standard CPM (see Annex B for more information). Neither of these standards directly addresses the issu
23、es of making measurements in small confined spaces or making measurements that better describe the effects of ionization on small objects (for example, integrated circuits or magnetoresistive heads). There is a need for a smaller, standardized test fixture that can be correlated to measurements made
24、 with the test fixture described in ANSI/ESD STM3.1. It should be as small as possible to allow measurements to be made in confined spaces (for example, the interior of automated equipment). This standard practice presents an example of a 2.54 cm x 2.54cm (1 inch x 1 inch) square test fixture and te
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSISP342012THEPROTECTIONOFELECTROSTATICDISCHARGESUSCEPTIBLEITEMSPERIODICVERIFICATIONOFAIRIONIZERPERFORMANCEUSINGASMALLTESTFIXTUREPDF

链接地址:http://www.mydoc123.com/p-438001.html