ANSI SP3.3-2012 The Protection of Electrostatic Discharge Susceptible Items - Periodic Verification of Air Ionizers.pdf
《ANSI SP3.3-2012 The Protection of Electrostatic Discharge Susceptible Items - Periodic Verification of Air Ionizers.pdf》由会员分享,可在线阅读,更多相关《ANSI SP3.3-2012 The Protection of Electrostatic Discharge Susceptible Items - Periodic Verification of Air Ionizers.pdf(23页珍藏版)》请在麦多课文档分享上搜索。
1、 Reaffirmation of ANSI/ESD SP3.3-2012 For the Protection of Electrostatic Discharge Susceptible Items - Periodic Verification of Air Ionizers Electrostatic Discharge Association 7900 Turin Road, Bldg. 3 Rome, NY 13440 An American National Standard Approved January 3, 2017 ANSI/ESD SP3.3-2016 ESD Ass
2、ociation Standard Practice for the Protection of Electrostatic Discharge Susceptible Items - Periodic Verification of Air Ionizers Approved September 23, 2016 EOS/ESD Association, Inc.ANSI/ESD SP3.3-2016 Electrostatic Discharge Association (ESDA) standards and publications are designed to serve the
3、public interest by eliminating misunderstandings between manufacturers and purchasers, facilitating the interchangeability and improvement of products and assisting the purchaser in selecting and obtaining the proper product for his particular needs. The existence of such standards and publications
4、shall not in any respect preclude any member or non-member of the Association from manufacturing or selling products not conforming to such standards and publications. Nor shall the fact that a standard or publication that is published by the Association preclude its voluntary use by non-members of
5、the Association whether the document is to be used either domestically or internationally. Recommended standards and publications are adopted by the ESDA in accordance with the ANSI Patent policy. Interpretation of ESDA Standards: The interpretation of standards in-so-far as it may relate to a speci
6、fic product or manufacturer is a proper matter for the individual company concerned and cannot be undertaken by any person acting for the ESDA. The ESDA Standards Chairman may make comments limited to an explanation or clarification of the technical language or provisions in a standard, but not rela
7、ted to its application to specific products and manufacturers. No other person is authorized to comment on behalf of the ESDA on any ESDA Standard. THE CONTENTS OF ESDAS STANDARDS AND PUBLICATIONS ARE PROVIDED “AS-IS,” AND ESDA MAKES NO REPRESENTATIONS OR WARRANTIES, EXPRESSED OR IMPLIED, OF ANY KIN
8、D WITH RESPECT TO SUCH CONTENTS. ESDA DISCLAIMS ALL REPRESENTATIONS AND WARRANTIES, INCLUDING WITHOUT LIMITATION, WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR USE, TITLE AND NON-INFRINGEMENT. ESDA STANDARDS AND PUBLICATIONS ARE CONSIDERED TECHNICALLY SOUND AT THE TIME THEY ARE
9、APPROVED FOR PUBLICATION. THEY ARE NOT A SUBSTITUTE FOR A PRODUCT SELLERS OR USERS OWN JUDGEMENT WITH RESPECT TO ANY PARTICULAR PRODUCT DISCUSSED, AND ESDA DOES NOT UNDERTAKE TO GUARANTEE THE PERFORMANCE OF ANY INDIVIDUAL MANUFACTURERS PRODUCTS BY VIRTUE OF SUCH STANDARDS OR PUBLICATIONS. THUS, ESDA
10、 EXPRESSLY DISLAIMS ANY RESPONSIBILITY FOR DAMAGES ARISING FROM THE USE, APPLICATION, OR RELIANCE BY OTHERS ON THE INFORMATION CONTAINED IN THESE STANDARDS OR PUBLICATIONS. NEITHER ESDA, NOR ITS MEMBERS, OFFICERS, EMPLOYEES OR OTHER REPRESENTATIVES WILL BE LIABLE FOR DAMAGES ARISING OUT OF, OR IN CO
11、NNECTION WITH, THE USE OR MISUSE OF ESDA STANDARDS OR PUBLICATIONS, EVEN IF ADVISED OF THE POSSIBILITY THEREOF. THIS IS A COMPREHENSIVE LIMITATION OF LIABILITY THAT APPLIES TO ALL DAMAGES OF ANY KIND, INCLUDING WITHOUT LIMITATION, LOSS OF DATA, INCOME OR PROFIT, LOSS OF OR DAMAGE TO PROPERTY AND CLA
12、IMS OF THIRD PARTIES. Published by: Electrostatic Discharge Association 7900 Turin Road, Bldg. 3 Rome, NY 13440 Copyright 2016 by ESD Association All rights reserved No part of this publication may be reproduced in any form, in an electronic retrieval system or otherwise, without the prior written p
13、ermission of the publisher. Printed in the United States of America ISBN: 1-58537-292-7DISCLAIMER OF WARRANTIES DISCLAIMER OF GUARANTY LIMITATION ON ESDAs LIABILITY CAUTION NOTICE ANSI/ESD SP3.3-2016 i (This foreword is not part of ESD Association Standard Practice ANSI/ESD SP3.3-2016) FOREWORD Grou
14、nding of conductive and static dissipative materials, personnel, and equipment is the primary method used to limit static charge for the protection of electrostatic discharge susceptible items in the work environment. A static control program may include air or nitrogen ionization techniques to miti
15、gate charge on isolated conductors (conductors that are not grounded), and insulating materials (e.g., most common plastics). The ionization standard test method, ANSI/ESD STM3.1, defines test methods and instrumentation, the Charged Plate Monitor (CPM), for making discharge (charge neutralization)
16、time and offset voltage (ion balance) measurements of air ionization equipment in defined environments. These standard test methods are applicable for product qualification, selecting an air ionizer for a specific application, as well as subsequently determining that the incoming product meets the s
17、election criteria. The test instrumentation and methods of the standard test method are also usable for compliance verification of ionizer performance per ESD TR53. ANSI/ESD STM3.1 also contains additional information regarding ionizer physics, ionizer measurement issues, and sources of measurement
18、error. The user is advised to review ANSI/ESD STM3.1 before using the procedures described in this standard practice1. Detailed performance testing under laboratory conditions may be required during selection, product qualification, and acceptance testing due to the variety of environments in which
19、ionizers are used. Periodic and compliance verification, however, are most often performed under actual use conditions. In general, all ionizers must be tested, rather than a sampling of product types or incoming lots. Periodic verification procedures should also be part of the initial acceptance pr
20、ocess to provide a baseline for comparison with future measurements. Compliance verification may be necessary to meet audit requirements. ANSI/ESD STM3.1 is sufficient to be used for product qualification, selection or acceptance testing, as well as for compliance verification. However, these proced
21、ures require a typically expensive test instrument and a substantial amount of time to test each ionizer. The cost of this testing is often unacceptable for purposes of periodic verification. There is a need for a simpler verification procedure using less expensive, preferably portable, test equipme
22、nt. Periodic verification provides a relative measure of performance and can indicate when it is necessary to check the calibration of the ionizer under test with the CPM (refer to ANSI/ESD STM3.1). This standard practice presents a test procedure and instrumentation for periodic verification of ion
23、izers contained in the existing ionization standard test method ANSI/ESD STM3.1. The test procedure can be carried out under actual use conditions and is capable of rapidly demonstrating ionizer performance. Discharge times and offset voltage testing contained in the ionization standard test method
24、were adapted for this periodic test procedure. It is important that a simplified verification procedure correlate reasonably with CPM test results. The objective of the test procedure described in this document is to identify if a significant change in ionizer performance has occurred. The test setu
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSISP332012THEPROTECTIONOFELECTROSTATICDISCHARGESUSCEPTIBLEITEMSPERIODICVERIFICATIONOFAIRIONIZERSPDF

链接地址:http://www.mydoc123.com/p-438000.html