ANSI NEIS 100-2013 Symbols for Electrical Construction Drawings.pdf
《ANSI NEIS 100-2013 Symbols for Electrical Construction Drawings.pdf》由会员分享,可在线阅读,更多相关《ANSI NEIS 100-2013 Symbols for Electrical Construction Drawings.pdf(66页珍藏版)》请在麦多课文档分享上搜索。
1、An AmericAn nAtionAl StAndArdNECA 100-2013 Symbols for ElectricalConstruction DrawingsPublished byNational Electrical Contractors AssociationSymbols for Electrical Construction DrawingsNECA 100-2013An AmericanNational StandardnullPublished byNational Electrical Contractors AssociationNOTICE OF COPYR
2、IGHTThis document is copyrighted by NECAReproduction of these documents either in hard copy or soft (including posting on the web) is prohibited without copyright permission. For copyright permission to reproduce portions of this document, please contact NECA Standards exterior transformers; feeders
3、, trunk lines and backbone cables between buildings; and site lighting.c) Symbol list and abbreviation list.d) Schedule(s) of lighting fixtures, mechanical equipment connections, transformers, etc. as appropriate. Typical schedules are shown in Annex B.e) Riser and/or one-line diagram(s) for power d
4、istribution and other systems, as appropriate. Typical riser and one-line diagrams are shown in Annex B.5 n1. Scope1.0 Wiring Methods 61.1 Raceways - Indicators 81.2 Raceways - Boxes and Busways 92.0 Luminaire Fixtures 102.1 Luminaire FixturesBasic ModifiersMounting 112.2 Luminaire Fixtures Basic Mo
5、difiersOrientation 112.3 Luminaire Fixtures Basic ModifiersEmergency 122.4 Luminaire FixturesExtended Modifiers 123.0 Outlets and Receptacles 134.0 Switches and Sensors 155.0 MotorsControls 175.1 Motorized and HVAC Equipment 206.0 Security 217.0 Fire Alarm Communications and Panels 237.1 Fire Alarm
6、Indicators 257.2 Fire Alarm Sensors 268.0 Power Distribution Equipment 289.0 Communications - Teledata 299.1 Communications - Audio/Visual 309.2 Communications - Equipment 3110.0 Site Work 3211.0 Schematic Fault Circuit Interrupter, Personal Protection 3311.1 One-Line Diagram SymbolsSwitchboard Mete
7、rs 3611.2 Schematic and One-Line Symbol DiagramsSwitches 3712.0 Miscellaneous 3913.0 Abbreviations 4014.0 Nurse Call System 43Contents for Symbol Groupsn 6NECA 100 Symbols for Electrical Construction Drawings1.0 RacewaysNumber Preferred Symbol Description1.0011.0021.0031.0041.0051.0061.0071.0081.009
8、1.0101.0111.0121.013Conduit concealed in finished areas, exposed in unfinished areas.Conduit concealed in or under floor slab.Non-rigid raceway system.Normal/emergency circuit.Emergency battery system wiring, minimum 10 AWG.Heat trace.Underfloor power raceway.Underfloor telecommunications raceway.Un
9、derfloor raceway for power and telecommunications.Underfloor signal raceway.Underfloor raceway for power, telephone, and data.Undercarpet flat conductor cable (FCC) wiring system, power.Undercarpet flat conductor cable (FCC) wiring system, tele-phoneNEEBHTPTPTSPTDUCPUCT7 nSymbols for Electrical Cons
10、truction Drawings NECA 1001.0 RacewaysNumber Preferred Symbol Description1.0 Raceways1.014Undercarpet flat conductor cable (FCC) wiring system, data.UCDn 8NECA 100 Symbols for Electrical Construction Drawings1.1 RacewaysIndicators1.101 Conduit stub. Terminate with bushing or cap if underground.1.102
11、 Conduit turning up.1.103 Conduit turning down.1.104 Indicates trade size 2 or 53 mm conduit with (4) 1 AWG and (1) 6 AWG ground.1.105 Indicates (2) trade size 2 or 53 mm conduits with (4) 1 AWG and (1) 6 AWG ground conductors in each conduit.1.106 Homerun to panelboard. Number of arrows indicates n
12、umber of circuits. (Example: Homerun to panel L211 CKTS. #1 and #3.)1.107 Flexible connection to equipment.1.108 Direct connection to equipment.1.109 Branch circuit, full hashes indicate ungrounded-“hot” (or switch-leg) circuit conductors. Half hashes indicates grounded neutral circuit conductors. (
13、No hashes indicates 1 hot and 1 neutral.) Dots indicate grounding conductors. Equipment bond size U.N.O. “IG” indicates an isolated grounding conductor.Number Preferred Symbol DescriptionSZ 2C,4#1 length, luminaire types and quan-tities as shown. (Track length drawn to scale.)n 12NECA 100 Symbols fo
14、r Electrical Construction DrawingsNumber Preferred Symbol Description2.3 Luminaire FixturesEmergency2.4 Luminaire FixturesExtended Modifiers2.300 Luminaire providing emergency illumination. (Filled in.)2.401 Standard designations for all luminaire fixtures.“A” = Fixture type, refer to fixture schedu
15、le“NL” = Unswitched night light“2” = Circuit number“a” = Switch control2.402 Mounting height.2.403 Louvers.2.404 Recessed, emergency fixture.AA NLaa22+1.2m (48 in.)NOTE: Modifiers are shown with specific base symbols for clarity. Each modifier can be used with any of the base symbols.13 nSymbols for
16、 Electrical Construction Drawings NECA 1003.0 Outlets and Receptacles3.001 Floor duplex receptacle. F=flush MTD. S=surface MTD.3.002 Duplex convenience receptacle. 20A 125V. 3.003 Duplex convenience receptacle on e mergency/standby circuit. Specify panelboard and circuit.3.004 Single convenience rec
17、eptacle.3.005 Single convenience receptacle on emergency/standby circuit. Specify panelboard and circuit.3.006 Double duplex convenience receptacle.3.007 Double duplex convenience receptacle on emergency/standby circuit. Specify panelboard and circuit.3.008 Multi-outlet assembly with outlets on cent
18、ers as indicated on the drawings and in the specifications, mounted 150 mm (6 in.) above counter or at height as directed, A - indicates type.3.009 Multioutlet assembly, devices as indicated.3.010 Special receptacle - typical notation:1 indicates example“1” = _A, _/_V., _ Pole, _ Wire, _ NEMA _-_“2”
19、 = _A, _/_V., _ Pole, _ Wire, _ NEMA _-_“3” = _A, _/_V., _ Pole, _ Wire, _ NEMA _-_3.011 Clock hanger outlet recessed mounted 2.5m (8) AFF or 200 mm (8 in.) below ceiling as appropriate and as directed.3.012 Flush mounted floor box, adjustable, with both power and voice/data receptacles.3.013 Juncti
20、on box. “AxBxC” indicates dimensions of junc-tion box in either inches or centimeters.Number Preferred Symbol DescriptionFEP2 CKT.1EP2 CKT.3EP2 CKT.5A11ORF1J JAxBxCn 14NECA 100 Symbols for Electrical Construction Drawings3.0 Outlets and Receptacles3.014 Duples receptacle ceiling mounted 20A 125V.3.0
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSINEIS1002013SYMBOLSFORELECTRICALCONSTRUCTIONDRAWINGSPDF

链接地址:http://www.mydoc123.com/p-437435.html