ANSI ASTM D6095-2012 Standard Test Method for Longitudinal Measurement of Volume Resistivity for Extruded Crosslinked and Thermoplastic Semiconducting Conductor and Insulation Shie.pdf
《ANSI ASTM D6095-2012 Standard Test Method for Longitudinal Measurement of Volume Resistivity for Extruded Crosslinked and Thermoplastic Semiconducting Conductor and Insulation Shie.pdf》由会员分享,可在线阅读,更多相关《ANSI ASTM D6095-2012 Standard Test Method for Longitudinal Measurement of Volume Resistivity for Extruded Crosslinked and Thermoplastic Semiconducting Conductor and Insulation Shie.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D6095 12Standard Test Method forLongitudinal Measurement of Volume Resistivity forExtruded Crosslinked and Thermoplastic SemiconductingConductor and Insulation Shielding Materials1This standard is issued under the fixed designation D6095; the number immediately following the designation
2、 indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers the procedur
3、e for determiningthe volume resistivity, measured longitudinally, of extrudedcrosslinked and thermoplastic semiconducting, conductor andinsulation shields for wire and cable.1.2 In common practice the conductor shield is often re-ferred to as the strand shield.1.3 Technically, this test method is th
4、e measurement of aresistance between two electrodes on a single surface andmodifying that value using dimensions of the specimen geom-etry to calculate a resistivity. However, the geometry of thespecimen is such as to support the assumption of a current pathprimarily throughout the volume of the mat
5、erial between theelectrodes, thus justifying the use of the term “longitudinalvolume resistivity.” (See 3.1.2.1)1.4 Whenever two sets of values are presented, in differentunits, the values in the first set are the standard, while those inparentheses are for information only.1.5 This standard does no
6、t purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For a specifichazard statement, see 7.1
7、.2. Referenced Documents2.1 ASTM Standards:2D257 Test Methods for DC Resistance or Conductance ofInsulating MaterialsD1711 Terminology Relating to Electrical InsulationD4496 Test Method for D-C Resistance or Conductance ofModerately Conductive Materials3. Terminology3.1 Definitions of Terms Specific
8、 to This Standard:3.1.1 semiconducting, adjmoderately conductive, see Ter-minology D1711 and Test Method D4496.3.1.2 longitudinal volume resistivity, nan electrical resis-tance multiplied by a factor calculated from the geometry of aspecimen volume between electrodes in contact with one, andonly one
9、, surface of the specimen.3.1.2.1 DiscussionIn normal wire and cable usage, thelongitudinal volume resistivity is simply referred to as “volumeresistivity.” This usage is at variance with terminology in TestMethods D257, Terminology D1711, and Test Method D4496.4. Significance and Use4.1 The electri
10、cal behavior of semiconducting extrudedshielding materials is important for a variety of reasons, suchas safety, static charges, and current transmission. This testmethod is useful in predicting the behavior of such semicon-ducting compounds. Also see Test Method D4496.5. Apparatus5.1 See Test Metho
11、d D4496 for a description of theapparatus, except the electrode system which is described in7.2.6. Sampling and Test Specimens6.1 Take one 2-ft (600-mm) sample from each lot, or fromeach 25000 ft (7600 m) of completed cable, whichever is less.6.2 The specimen consists of a 10 in. (250 mm) length ofc
12、able core with all layers external to the semi-conductinginsulation shield removed. Use this specimen to test theinsulation shield. To test the conductor shield, bisect thesample longitudinally and remove the conductor. Use only onepiece of the conductor shield as the test specimen.6.3 Condition the
13、 specimens in accordance with TestMethod D4496.6.3.1 If the shielding materials are crosslinked, conditionthe cable core (jacket removed) overnight at 50C to eliminate1This test method is under the jurisdiction of ASTM Committee D09 onElectrical and Electronic Insulating Materials and is the direct
14、responsibility ofSubcommittee D09.07 on Electrical Insulating Materials.Current edition approved Nov. 1, 2012. Published November 2012. Originallyapproved in 1997. Last previous edition approved in 2006 as D6095 06. DOI:10.1520/D6095-12.2For referenced ASTM standards, visit the ASTM website, www.ast
15、m.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box
16、 C700, West Conshohocken, PA 19428-2959. United States1any acetophenone that is potentially present. Then proceedwith the conditioning in accordance with Test Method D4496.7. Procedure7.1 WarningThoroughly instruct all operators as to thecorrect procedures for performing tests safely.7.2 Apply an el
17、ectrode system consisting of four annularbands of silver paint approximately 0.25 in. (6.5 mm) wide tothe insulation shield. There must be a distance of at least 2 in.(50 mm) of shield between the potential electrodes (the twoinner bands) and a distance of 1 in. of shield between thecurrent electrod
18、es (the outer bands) and the potential elec-trodes. See Annex A1 of Test Method D4496.7.3 For measurement of the conductor shield, bisect thesample longitudinally and remove the conductor. Then, usingonly one piece of the bisected shield, apply the silver paintelectrode system as described in 7.2 on
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
2000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIASTMD60952012STANDARDTESTMETHODFORLONGITUDINALMEASUREMENTOFVOLUMERESISTIVITYFOREXTRUDEDCROSSLINKEDANDTHERMOPLASTICSEMICONDUCTINGCONDUCTORANDINSULATIONSHIEPDF
链接地址:http://www.mydoc123.com/p-432436.html