ANSI ASME A112.4.1-2009 Water Heater Relief Valve Drain Tubes《热水器减压阀排水管》.pdf
《ANSI ASME A112.4.1-2009 Water Heater Relief Valve Drain Tubes《热水器减压阀排水管》.pdf》由会员分享,可在线阅读,更多相关《ANSI ASME A112.4.1-2009 Water Heater Relief Valve Drain Tubes《热水器减压阀排水管》.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、AN AMERICAN NATIONAL STANDARDASME A112.4.1-2009Revision of ASME A112.4.1-1993 (R2008)Water Heater Relief Valve Drain TubesIntentionally left blank ASME A112.4.1-2009Revision of ASME A112.4.1-1993 (R2008)Water HeaterRelief ValveDrain TubesAN AMERICAN NATIONAL STANDARDDate of Issuance: January 11, 201
2、0This Standard will be revised when the Society approves the issuance of a new edition. There willbe no addenda or written interpretations of the requirements of this Standard issued to this edition.Periodically certain actions of the ASME A112 Committee may be published as Cases. Cases arepublished
3、 on the ASME Web site under the Committee Pages at http:/cstools.asme.org as they areissued.ASME is the registered trademark of The American Society of Mechanical Engineers.This code or standard was developed under procedures accredited as meeting the criteria for American NationalStandards. The Sta
4、ndards Committee that approved the code or standard was balanced to assure that individuals fromcompetent and concerned interests have had an opportunity to participate. The proposed code or standard was madeavailable for public review and comment that provides an opportunity for additional public i
5、nput from industry, academia,regulatory agencies, and the public-at-large.ASME does not “approve,” “rate,” or “endorse” any item, construction, proprietary device, or activity.ASME does not take any position with respect to the validity of any patent rights asserted in connection with anyitems menti
6、oned in this document, and does not undertake to insure anyone utilizing a standard against liability forinfringement of any applicable letters patent, nor assumes any such liability. Users of a code or standard are expresslyadvised that determination of the validity of any such patent rights, and t
7、he risk of infringement of such rights, isentirely their own responsibility.Participation by federal agency representative(s) or person(s) affiliated with industry is not to be interpreted asgovernment or industry endorsement of this code or standard.ASME accepts responsibility for only those interp
8、retations of this document issued in accordance with the establishedASME procedures and policies, which precludes the issuance of interpretations by individuals.No part of this document may be reproduced in any form,in an electronic retrieval system or otherwise,without the prior written permission
9、of the publisher.The American Society of Mechanical EngineersThree Park Avenue, New York, NY 10016-5990Copyright 2010 byTHE AMERICAN SOCIETY OF MECHANICAL ENGINEERSAll rights reservedPrinted in U.S.A.CONTENTSForeword ivCommittee Roster . vCorrespondence With the A112 Committee . vi1 General . 12 Req
10、uirements 13 Test Methods and Performance Requirements 1iiiFOREWORDThere are potential hazards associated with the heating of water in a closed vessel, as thepotential for excessive temperature or pressure development within such closed systems is alwayspresent. In order to reduce the hazards associ
11、ated with water heating, two special amendmentshave been added to the plumbing codes and standards over the past few decades that haveresulted in much safer installations. The first requirement involved the installation of a high limitcontrol in the water heating assembly, which deactivates the fuel
12、 gas control mechanism ifthe water heating device exceeds a specific temperature. The second requirement involved theinstallation of a temperature and pressure relief valve, which is designed to open to atmosphereif the water temperature or pressure within a vessel exceeds the defined specifications
13、 of thevalve. Properly inspected and maintained, these devices provide the “state-of-the-art“ in waterheater safety.For many years, relief valve drains were field-fabricated from metallic piping. With the increas-ing use of plastics and the need for more expedient installations of plumbing component
14、s, theASME A112 Committee undertook the task of developing criteria for the performance of waterheater relief valve drains.It is intended that this Standard serve as a uniform reference document for use by manufacturers,inspectors, contractors, and installers to identify criteria applicable to water
15、 heater relief valvedrain tubes.When this Standard was first developed in 1993, the standard relief valve rating of residentialwater heaters was 100,000 Btu/hr. Today the common industry rating is 105,000 Btu/hr for therelief valves. This revision reflects this change.Suggestions for improvement of
16、this Standard are welcome. They should be sent to TheAmerican Society of Mechanical Engineers, Attn: Secretary, A112 Standards Committee, ThreePark Avenue, New York, NY 10016-5990. The ASME A112 Standards Committee approved theStandard and it was subsequently adopted as an American National Standard
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIASMEA112412009WATERHEATERRELIEFVALVEDRAINTUBES 热水器 减压阀 排水管 PDF

链接地址:http://www.mydoc123.com/p-431639.html