AIR FORCE A-A-59355-1998 LEAK DETECTOR HELIUM《氦检漏仪》.pdf
《AIR FORCE A-A-59355-1998 LEAK DETECTOR HELIUM《氦检漏仪》.pdf》由会员分享,可在线阅读,更多相关《AIR FORCE A-A-59355-1998 LEAK DETECTOR HELIUM《氦检漏仪》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、 - A-A-59355 9038054 O003973 838 = -Beneficial cmments, recommendations, additions, deletions, clarifications, etc., and any data which may improve this document should be sent to SA-ALC/TILDD, 485 Quentin Roosevelt Rd., Kelly AFB, TX 78241-6425 by using the Standardization Document Improvement Prop
2、osal (DD Form 1426) appearing at the end of this document. I INCH-POUNDI A-A-59355 19 October 1998 COMMERCIAL ITEM DESCRIPTION LEAK DETECTOR, HELIUM The General Services Administration has authorized the use of this Commercial Item Description (CID) for all federal agencies. 1. This detector will be
3、 used to calibrate mass spectrometers at military installations around the world. SCOPE. This document outlines the minimum requirements for a helium leak detector. 2. SALIENT CHARACTERISTICS. 2.1 General. This calibrated helium leak detector consists of a controlled source of helium ion gas traceab
4、le to the National Institute of Standards and Technology (NIST) external reference standards used in calibrating leak detectors. . 2.2 Leak rate. The leak rate is factor relates to the minimum detectable leak rate in std cclsec for helium molecules (1 std cdsec = 0.76 torr-litedsec). std cc/sec mini
5、mum detectable partial pressure of helium. This 2.3 Leak rate accuracv. The leak rate shall be less than or equal to 2 10 percent std cc/sec. 2.4 Media. The media shall be helium gas. 2.5 Tvpe of leak. External application. 2.6 Fittings. 1- 1/8-inch outside diameter compression fitting. 2.7 Value ty
6、pe. Manual isolation. AMSC NIA FSC 4940 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59355 9038054 0003972 774 A-A-5 93 5 5 2.8 Outer casing material. Corrosion-resistant stainless steel. 2.9 Calibration. Each leak detector shall be calibrated
7、 and traceable to the NIST reference standard. 2.10 Marking. As a minimum, the helium leak detector should be permanently marked with the following information: type of calibration gas for the mass spectrometer, helium leak rate, date the calibration leak was filled with gas, calibration temperature
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
2000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AIRFORCEAA593551998LEAKDETECTORHELIUM 检漏 PDF

链接地址:http://www.mydoc123.com/p-427084.html