1、Standard Specification for Reinforced Concrete D-Load Culvert, Storm Drain, and Sewer Pipe AASHTO Designation: M 242M/M 242-151ASTM Designation: C655M-12b and C655-12b American Association of State Highway and Transportation Officials 444 North Capitol Street N.W., Suite 249 Washington, D.C. 20001 T
2、S-4a M 242M/M 242-1 AASHTO Standard Specification for Reinforced Concrete D-Load Culvert, Storm Drain, and Sewer Pipe AASHTO Designation: M 242M/M 242-151 ASTM Designation: C655M-12b and C655-12b 1. SCOPE 1.1. This specification covers reinforced concrete pipe designed for specific D-loads and inten
3、ded to be used for the conveyance of sewage, industrial wastes, and storm water, and for the construction of culverts. 1.2. This specification is applicable for orders in either SI units (M 242M) or in inch-pound units (M 242). SI units and inch-pound units are not necessarily equivalent. Inch-pound
4、 units are shown in brackets in the text for clarity, but they are the applicable values when the material is ordered to M 242. Note 1Experience has shown that the successful performance of this product depends upon the proper selection of the pipe strength, the type of bedding and backfill, the car
5、e that the installation conforms to the construction specifications, and provision for adequate inspection at the construction site. This specification does not include requirements for bedding, backfill, the relationship between field load conditions and the strength designation of pipe, or durabil
6、ity under unusual environmental conditions. These requirements should be included in the project specification. 2. REFERENCED DOCUMENTS 2.1. AASHTO Standards: M 6, Fine Aggregate for Hydraulic Cement Concrete M 31M/M 31, Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement M 32M/M 32, Ste
7、el Wire, Plain, for Concrete Reinforcement M 55M/M 55, Steel Welded Wire Reinforcement, Plain, for Concrete M 80, Coarse Aggregate for Hydraulic Cement Concrete M 85, Portland Cement M 221M/M 221, Steel Welded Wire Reinforcement, Deformed, for Concrete M 225M/M 225, Steel Wire, Deformed, for Concret
8、e Reinforcement M 240M/M 240, Blended Hydraulic Cement M 262, Concrete Pipe and Related Products M 295, Coal Fly Ash and Raw or Calcined Natural Pozzolan for Use in Concrete M 302, Slag Cement for Use in Concrete and Mortars T 280, Concrete Pipe, Manhole Sections, or Tile 2015 by the American Associ
9、ation of State Highway and Transportation Officials.All rights reserved. Duplication is a violation of applicable law.TS-4a M 242M/M 242-2 AASHTO 2.2. ASTM Standards: C33/C33M, Standard Specification for Concrete Aggregates C1116/C1116M, Standard Specification for Fiber-Reinforced Concrete E105, Sta
10、ndard Practice for Probability Sampling of Materials MNL7, Manual on Presentation of Data and Control Chart Analysis, 8th Edition STP15-C, Manual on Quality Control of Materials 3. TERMINOLOGY 3.1. DefinitionsFor definitions of terms relating to concrete pipe, see M 262. 4. BASIS OF ACCEPTANCE 4.1.
11、The acceptability of the pipe design shall be determined in accordance with Section 9. After the pipe design has been accepted, or if the pipe design has been accepted previously in accordance with Section 9, the owner may select and have applied the basis of acceptance described in either Section 4
12、.1.1 or Section 4.1.2. Unless designated by the owner at the time of, or before placing an order, either basis of acceptance shall be permitted. 4.1.1. Acceptance on the Basis of Pipe Load and Material Tests and Inspection of Manufactured Pipe for DefectsDetermine in accordance with Sections 5, 6, 8
13、, and 10. Note 2It is necessary that samples be selected at random. For guidance, see ASTM E105. 4.1.2. Acceptance on the Basis of Concrete Compression and Materials Tests and Inspection of Manufactured Pipe for DefectsDetermine in accordance with Sections 5, 6, 8, and 11. 4.2. Age for AcceptancePip
14、e shall be considered ready for acceptance when they conform to the requirements. 5. DESIGN AND MANUFACTURING DATA 5.1. The manufacturer shall provide the following information regarding the pipe unless waived by the owner: 5.1.1. Basis of acceptance, and 5.1.2. Pipe design strength. 5.1.3. Physical
15、 Characteristics: 5.1.3.1. Diameter, wall thickness, laying length, and joint details; 5.1.4. Design concrete strength, minimum cf equals 27.6 MPa 4000 psi; and 5.1.5. Admixtures. 2015 by the American Association of State Highway and Transportation Officials.All rights reserved. Duplication is a vio
16、lation of applicable law.TS-4a M 242M/M 242-3 AASHTO 5.1.6. Reinforcement: 5.1.6.1. Type of reinforcement, applicable reinforcement specification, and grade; and 5.1.6.2. Placement, placement tolerances, diameter, spacing and cross-sectional area of circumferential, longitudinal, and special reinfor
17、cement. 5.1.7. Manufacturing and curing process. 6. MATERIALS AND MANUFACTURE 6.1. Materials: 6.1.1. Reinforced ConcreteThe reinforced concrete shall consist of cementitious materials, mineral aggregates, and water, in which steel has been embedded in such a manner that the steel and concrete act to
18、gether. 6.1.2. Cementitious Materials: 6.1.2.1. CementCement shall conform to the requirements for portland cement of M 85 or shall be portland blast-furnace slag cement or portland-pozzolan cement conforming to the requirements of M 240M/M 240, except that the pozzolan constituent in the Type IP po
19、rtland-pozzolan cement shall be fly ash. 6.1.2.2. Fly AshFly ash shall conform to the requirements of M 295, Class F or Class C. 6.1.2.3. Ground Granulated Blast-Furnace Slag (GGBFS)GGBFS shall conform to the requirements of Grade 100 or 120 of M 302. 6.1.2.4. Allowable Combinations of Cementitious
20、MaterialsThe combination of cementitious materials used in the concrete shall be one of the following: a) Portland cement only, b) Portland blast-furnace slag cement only, c) Portland-pozzolan cement only, d) A combination of portland cement and fly ash, e) A combination of portland cement and groun
21、d granulated blast-furnace slag, f) A combination of portland cement, ground granulated blast-furnace slag, and fly ash, or g) A combination of portland-pozzolan cement and fly ash, provided the fly ash added does not exceed 25 percent by weight of the portland-pozzolan cements. 6.1.3. AggregatesAgg
22、regates shall conform to the requirements of M 6 and M 80, except that the requirements for gradation shall not apply. 6.1.4. Admixtures and BlendsAdmixtures and blends shall be allowed unless prohibited by the owner. 6.1.5. Steel ReinforcementReinforcement shall consist of wire conforming to M 32M/
23、M 32 or M 225M/M 225, or of wire fabric conforming to M 55M/M 55 or M 221M/M 221, or of bars of Grade 300 40 steel conforming to M 31M/M 31. 2015 by the American Association of State Highway and Transportation Officials.All rights reserved. Duplication is a violation of applicable law.TS-4a M 242M/M
24、 242-4 AASHTO 6.2. Manufacture: 6.2.1. MixtureThe aggregates shall be sized, graded, proportioned, and mixed with such proportions of cementitious materials, water, and admixtures, if any, to produce a thoroughly mixed concrete of such quality that the pipe will conform to the test and design requir
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AASHTOM242MM2422015STANDARDSPECIFICATIONFORREINFORCEDCONCRETEDLOADCULVERTSTORMDRAINANDSEWERPIPEPDF

链接地址:http://www.mydoc123.com/p-417733.html