BS PD ISO TS 16976-2-2015 Respiratory protective devices Human factors Anthropometrics《呼吸保护装置 人体因素 人体测量术》.pdf
《BS PD ISO TS 16976-2-2015 Respiratory protective devices Human factors Anthropometrics《呼吸保护装置 人体因素 人体测量术》.pdf》由会员分享,可在线阅读,更多相关《BS PD ISO TS 16976-2-2015 Respiratory protective devices Human factors Anthropometrics《呼吸保护装置 人体因素 人体测量术》.pdf(34页珍藏版)》请在麦多课文档分享上搜索。
1、BSI Standards Publication Respiratory protective devices Human factors Part 2: Anthropometrics PD ISO/TS 16976-2:2015National foreword This Published Document is the UK implementation of ISO/TS 16976-2:2015. It superdedes DD ISO/TS 16976-2:2010 which is withdrawn. The UK participation in its prepara
2、tion was entrusted to Technical Committee PH/4, Respiratory protection. A list of organizations represented on this committee can be obtained on request to its secretary. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct ap
3、plication. The British Standards Institution 2015. Published by BSI Standards Limited 2015 ISBN 978 0 580 89493 0 ICS 13.340.30 Compliance with a British Standard cannot confer immunity from legal obligations. This Published Document was published under the authority of the Standards Policy and Stra
4、tegy Committee on 31 May 2015. Amendments/corrigenda issued since publication Date Text affected PUBLISHED DOCUMENT PD ISO/TS 16976-2:2015 ISO 2015 Respiratory protective devices Human factors Part 2: Anthropometrics Appareils de protection respiratoire Facteurs humains Partie 2: Anthropomtrie TECHN
5、ICAL SPECIFICATION ISO/TS 16976-2 Reference number ISO/TS 16976-2:2015(E) Second edition 2015-04-01 PD ISO/TS 16976-2:2015 ISO/TS 16976-2:2015(E)ii ISO 2015 All rights reserved COPYRIGHT PROTECTED DOCUMENT ISO 2015 All rights reserved. Unless otherwise specified, no part of this publication may be r
6、eproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting on the internet or an intranet, without prior written permission. Permission can be requested from either ISO at the address below or ISOs member body in the country of the reque
7、ster. ISO copyright office Case postale 56 CH-1211 Geneva 20 Tel. + 41 22 749 01 11 Fax + 41 22 749 09 47 E-mail copyrightiso.org Web www.iso.org Published in Switzerland PD ISO/TS 16976-2:2015 ISO/TS 16976-2:2015(E)Foreword iv Introduction v 1 Scope . 1 2 Normative references 1 3 T erms and definit
8、ions . 1 4 Anthropometric measurements . 1 4.1 Anthropometric instrument and software . 1 4.2 Measurement procedures 2 4.2.1 Landmarking . 2 4.2.2 Measuring 2 4.3 Dimensions to be measured 2 5 Anthropometric data for head, face, and neck dimensions . 3 6 Anthropometric data for torso dimensions . 5
9、7 Interface between headform and torso 6 8 Human test panels for facial features . 7 8.1 General . 7 8.2 Bivariate panel 7 8.3 Principal component analysis (PCA) panel 8 9 Models of headforms .12 Annex A (normative) Description, definition, and diagr ams of select ed landmar ks .15 Annex B (normativ
10、e) Description, definition, and diagr am of dimensions t o be measured 18 Annex C (informative) Examples of application of human test panels for facial features .21 Bibliogr aph y .24 ISO 2015 All rights reserved iii Contents Page PD ISO/TS 16976-2:2015 ISO/TS 16976-2:2015(E) Foreword ISO (the Inter
11、national Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has
12、been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical st
13、andardization. The procedures used to develop this document and those intended for its further maintenance are described in the ISO/IEC Directives, Part 1. In particular the different approval criteria needed for the different types of ISO documents should be noted. This document was drafted in acco
14、rdance with the editorial rules of the ISO/IEC Directives, Part 2 (see www.iso.org/directives). Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Detai
15、ls of any patent rights identified during the development of the document will be in the Introduction and/or on the ISO list of patent declarations received (see www.iso.org/patents). Any trade name used in this document is information given for the convenience of users and does not constitute an en
16、dorsement. For an explanation on the meaning of ISO specific terms and expressions related to conformity assessment, as well as information about ISOs adherence to the WTO principles in the Technical Barriers to Trade (TBT) see the following URL: Foreword - Supplementary information The committee re
17、sponsible for this document is ISO/TC 94, Personal safety Protective clothing and equipment, Subcommittee SC 15, Respiratory protective devices. This second edition cancels and replaces the first edition (ISO/TS 16976-2:2010), which has been technically revised. It also incorporates the Technical Co
18、rrigendum ISO 16976-2 Corr.1:2011. The major technical changes are: a) Inclusion of ISO/TS 16976-2 TECHNICAL CORRIGENDUM 1:2011 b) Change of values for W 5and W 6in 8.3. ISO/TS 16976 consists of the following parts, under the general title Respiratory protective devices Human factors: Part 1: Metabo
19、lic rates and respiratory flow rates Technical Specification Part 2: Anthropometrics Technical Specification Part 3: Physiological responses and limitations of oxygen and limitations of carbon dioxide in the breathing environment Technical Specification Part 4: Work of breathing and breathing resist
20、ance: Physiologically based limits Technical Specification Part 5: Thermal effects Technical Specification Part 6: Psycho-physiological effects Technical Specification Part 7: Hearing and speech Technical Specification Part 8: Ergonomic factors Technical Specificationiv ISO 2015 All rights reserved
21、PD ISO/TS 16976-2:2015 ISO/TS 16976-2:2015(E) Introduction For an appropriate design, selection, and use of respiratory protective devices, basic physiological demands of the user must be considered. Type and intensity of work affect the metabolic rate (energy expenditure) of the wearer. Weight and
22、weight distribution of the device on the human body can also influence metabolic rate. Metabolic rate is directly correlated with oxygen consumption, which determines the respiratory demands and flow rates. The work of breathing is influenced by the air flow resistances of the device and the lung ai
23、rways. The work (or energy cost) of a breath is related to the pressure gradient created by the breathing muscles and the volume that is moved in and out of the lung during the breath. Anthropometric and biomechanical data are required for appropriate design of various components of a respiratory pr
24、otective device, as well as for the design of relevant test methods. This Technical Specification forms one part of a series of documents providing basic anthropometric measurement methods and data on humans. It contains information about the description, definition, and diagram of landmarks and dim
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSPDISOTS1697622015RESPIRATORYPROTECTIVEDEVICESHUMANFACTORSANTHROPOMETRICS 呼吸 保护装置 人体 因素 测量 PDF

链接地址:http://www.mydoc123.com/p-398939.html