BS PD IEC TR 62001-2-2016 High-voltage direct current (HVDC) systems Guidance to the specification and design evaluation of AC filters Performance《高压直流(HVDC)系统 交流滤波器的规格和设计.pdf
《BS PD IEC TR 62001-2-2016 High-voltage direct current (HVDC) systems Guidance to the specification and design evaluation of AC filters Performance《高压直流(HVDC)系统 交流滤波器的规格和设计.pdf》由会员分享,可在线阅读,更多相关《BS PD IEC TR 62001-2-2016 High-voltage direct current (HVDC) systems Guidance to the specification and design evaluation of AC filters Performance《高压直流(HVDC)系统 交流滤波器的规格和设计.pdf(74页珍藏版)》请在麦多课文档分享上搜索。
1、High-voltage direct current (HVDC) systems Guidance to the specification and design evaluation of AC filters Part 2: Performance PD IEC/TR 62001-2:2016 BSI Standards Publication WB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06National foreword This Published Document is the UK implementation
2、 of IEC/TR 62001- 2:2016. Together with PD IEC/TR 62001-1:2016, PD IEC/TR 62001-3 and PD IEC/TR 62001-4:2016, it supersedes PD IEC/TR 62001:2009 which will be withdrawn on publication of all parts of this series. The UK participation in its preparation was entrusted to Technical Committee PEL/22, Po
3、wer electronics. A list of organizations represented on this committee can be obtained on request to its secretary. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. The British Standards Institution 2016. Publ
4、ished by BSI Standards Limited 2016 ISBN 978 0 580 91367 9 ICS 29.200 Compliance with a British Standard cannot confer immunity from legal obligations. This Published Document was published under the authority of the Standards Policy and Strategy Committee on 31 August 2016. Amendments/corrigenda is
5、sued since publication Date Text affected PUBLISHED DOCUMENT PD IEC/TR 62001-2:2016 IEC TR 62001-2 Edition 1.0 2016-07 TECHNICAL REPORT High-voltage direct current (HVDC) systems Guidance to the specification and design evaluation of AC filters Part 2: Performance INTERNATIONAL ELECTROTECHNICAL COMM
6、ISSION ICS 29.200 ISBN 978-2-8322-3540-9 Registered trademark of the International Electrotechnical Commission Warning! Make sure that you obtained this publication from an authorized distributor. colour inside PD IEC/TR 62001-2:2016 2 IEC TR 62001-2:2016 IEC 2016 CONTENTS FOREWORD 5 INTRODUCTION 7
7、1 Scope .8 2 Normative references 8 3 Current-based interference criteria 8 3.1 General 8 3.2 Determining the necessity for telephone interference limits 9 3.3 Defining telephone interference limits 11 3.3.1 General . 11 3.3.2 Mechanisms of interference . 11 3.3.3 Noise performance coordination leve
8、ls . 13 3.3.4 Influence of power transmission lines . 14 3.3.5 Determination of IT limits for a specific project . 19 3.3.6 Pre-existing harmonics and future growth . 23 3.3.7 Recommendations for technical specifications 25 3.4 Consequences for filter design 26 3.5 Telephone infrastructure mitigatio
9、n options . 27 3.6 Experience and examples . 28 3.6.1 General . 28 3.6.2 Review of design requirements 28 3.6.3 Measured current levels of schemes in service . 30 3.6.4 Example of actual telephone interference problems 31 3.6.5 Experience in China, showing no interference problems . 33 3.7 Conclusio
10、ns 33 4 Field measurements and verification 34 4.1 Overview 34 4.2 Equipment and subsystem tests 34 4.2.1 General . 34 4.2.2 Fundamental frequency impedance and unbalance measurement . 34 4.2.3 Frequency response curve . 34 4.3 System tests . 35 4.4 Measuring equipment 35 4.4.1 Overview . 35 4.4.2 A
11、C filter energization . 36 4.4.3 Verification of the reactive power controller 36 4.4.4 Verification of the specified reactive power interchange 36 4.4.5 Verification of the harmonic performance . 37 4.4.6 Verification of audible noise . 39 4.5 In-service measurements 41 4.5.1 General . 41 4.5.2 In-
12、service tuning checks 41 4.5.3 On-line monitoring of tuning . 41 4.5.4 Monitoring of IT performance . 41 4.5.5 Measurements of pre-existing harmonic levels for design purposes 41 Annex A (informative) Voltage and current distortion Telephone interference . 42 A.1 Voltage distortion limits for HV and
13、 EHV networks . 42 PD IEC/TR 62001-2:2016IEC TR 62001-2:2016 IEC 2016 3 A.1.1 General . 42 A.1.2 Recommended limits for HV or EHV networks 43 A.2 Harmonic current in generators . 45 A.3 Causes of telephone interference 45 A.4 Definition of telephone interference parameters . 47 A.5 Discussion 50 A.6
14、 Coupling mechanism from power-line current to telephone disturbance voltage 51 Annex B (informative) Example of induced noise calculation with Dubanton equations 52 B.1 General 52 B.2 Residual IT . 52 B.3 Balanced IT 53 Annex C (informative) Illustration of the benefit of including a TIF requiremen
15、t in the technical specification. 54 Annex D (informative) Specification of IT limits dependent on network impedance 56 Annex E (informative) The impact of AC network harmonic impedance and voltage level on the filter design necessary to fulfil an IT criterion 60 E.1 General 60 E.2 Assumptions and p
16、re-conditions 61 E.3 Harmonic impedance of AC network 63 E.4 Filter design 65 E.5 Explanation of the difference in impact of relative and absolute performance criteria on required filter Mvar . 67 Bibliography . 68 Figure 1 Conversion factor from positive sequence current at the sending end to posit
17、ive sequence current at the receiving end, and input impedance of a 230 kV line, 124 km long, 1000 -m . 21 Figure 2 Conversion factor from positive sequence current to residual current, and input impedance of a 230 kV line, 124 km long, 1 000 -m 21 Figure 3 Simple circuit for calculation of harmonic
18、 performance taking into account pre-existing harmonics 23 Figure 4 Converter variables for harmonic performance tests . 37 Figure 5 Example of measurements made during a ramp of the converters . 40 Figure A.1 Contributions of harmonic voltages at different voltage levels in a simple network 42 Figu
19、re A.2 C-message and psophometric weighting factors 46 Figure A.3 Flow-chart describing the basic telephone interference mechanism . 51 Figure D.1 Simplification of the detailed network used for telephone interference simulation . 56 Figure D.2 Induced voltage in telephone circuit vs. network impeda
20、nce, for unitary current injected . 57 Figure D.3 IT limits as defined for different network impedances 58 Figure E.1 Converter harmonics un-weighted (A) and IT weighted (kA) on 240 kV base . 62 Figure E.2 Converter Mvar absorption versus load . 63 Figure E.3 Impedance sector diagram and RL-equivale
21、nt circuit . 64 Figure E.4 Simplified converter/system topology 64 Figure E.5 Simplified circuit including overhead transmission line . 65 PD IEC/TR 62001-2:2016 4 IEC TR 62001-2:2016 IEC 2016 Table 1 Performance thresholds for metallic noise . 14 Table 2 Performance thresholds for longitudinal nois
22、e 14 Table 3 Performance thresholds for balance 14 Table 4 Illustrative maximum telephone line length to achieve the North American recommended longitudinal N glevel, as a function of balanced IT level, earth resistivity and separation distance 17 Table 5 Illustrative maximum telephone line length t
23、o achieve the North American recommended longitudinal N glevel as a function of residual IT level, earth resistivity and separation distance 18 Table 6 Some HVDC schemes Specified telephone interference criteria 29 Table 7 Measured 95 % values of THFF and I peof a 600 MW scheme (3 phases) 31 Table 8
24、 Measured 95 % values of THFF and I peof a 300 MW scheme (3 phases) 31 Table A.1 Voltage distortion limits from IEEE 519-1992 43 Table A.2 Compatibility levels for harmonic voltages (in percent of the nominal voltage) in LV and MV power systems based on Table 1 of IEC TR 61000-3-6:2008 44 Table A.3
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSPDIECTR6200122016HIGHVOLTAGEDIRECTCURRENTHVDCSYSTEMSGUIDANCETOTHESPECIFICATIONANDDESIGNEVALUATIONOFACFILTERSPERFORMANCE

链接地址:http://www.mydoc123.com/p-397686.html