ISO 3390-1976 Aluminium oxide primarily used for the production of aluminium Determination of manganese content Flame atomic absorption method《主要用于铝生产的氧化铝 锰含量的测.pdf
《ISO 3390-1976 Aluminium oxide primarily used for the production of aluminium Determination of manganese content Flame atomic absorption method《主要用于铝生产的氧化铝 锰含量的测.pdf》由会员分享,可在线阅读,更多相关《ISO 3390-1976 Aluminium oxide primarily used for the production of aluminium Determination of manganese content Flame atomic absorption method《主要用于铝生产的氧化铝 锰含量的测.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、INTERNATIONAL STANDARD INTERNATIONAL ORGAN!LATION FOR STANDARDIZATION .ML,k;1SH4PU.H4R OPrAHU34”UR rl0 CTAHLIAPTU34UUU .ORGANISATION INTERNATIONALE DE NORMALISATION Aluminium oxide primarily used for the production of aluminium - Determination of manganese content - Flame atomic absorption method Ox
2、yde daluminium principalement utilise pour la production de Ialuminium - Dosage du mangantke - Methode par absorption atomique dans la flamme First edition - 1976-09-01 ?!“H” $ ij ,j.;1”;3: ;j: ,f ,6” i j-(,:jy;Z.J(;R.i :,;jqj(: + .I* ,!I *i Y r _I ; s . UDC 661.862.22 : 546.711 : 543.422 Ref. No. I
3、S0 3390-1976 (E) Descriptors : aluminium oxide, chemical analysis, determination of content, manganese, spectrophotometric analysis, atomic absorption spectroscopic analysis. Price based on 6 pages Copyright International Organization for Standardization Provided by IHS under license with ISONot for
4、 ResaleNo reproduction or networking permitted without license from IHS-,-,-FOREWORD IS0 (the International Organization for Standardization) is a worldwide federation of national standards institutes (IS0 Member Bodies). The work of developing International Standards is carried out through IS0 Tech
5、nical Committees. Every Member Body interested in a subject for which a Technical Committee has been set up has the right to be represented on that Committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. Draft International Standard
6、s adopted by the Technical Committees are circulated to the Member Bodies for approval before their acceptance as International Standards by the IS0 Council. International Standard IS0 3390 was drawn up by Technical Committee ISO/TC 47, Chemistry, and was circulated to the Member Bodies in May 1974.
7、 It has been approved by the Member Bodies of the following countries : Austria Belgium Bulgaria Chile Czechoslovakia Egypt, Arab Rep. of France Germany Hungary India Israel Italy Netherlands New Zealand Poland Portugal No Member Body expressed disapproval of the document. South Africa, Rep. of Spai
8、n Sweden Switzerland Thailand Turkey United Kingdom Yugoslavia 0 International Or9mization for Standardization, 1976 l Printed in Switzerland Copyright International Organization for Standardization Provided by IHS under license with ISONot for ResaleNo reproduction or networking permitted without l
9、icense from IHS-,-,-INTERNATIONAL STANDARD IS0 3390-1976 (E) Aluminium oxide primarily used for the production of aluminium - Determination of manganese content - Flame atomic absorption method 1 SCOPE AND FIELD OF APPLICATION This International Standard specifies a flame atomic absorp- tion method
10、for the determination of the manganese con- tent of aluminium oxide primarily used for the production of aluminium. The method is applicable to products of which the manga- nese content, expressed as Mn, is between 0,000 2 and 0,005 % (m/m) (0,000 258 and 0,006 46 % (m/m), express- ed as MnO). NOTE
11、- If the apparatus available does not have a sufficient sensi- tivity for the lower contents of manganese, it is recommended that there should be pnor extraction of the manganese, by the method specified in annex A. 2 REFERENCES IS0 802, Aluminium oxide primarily used for the produc- tion of alumini
12、um - Preparation and storage of test samples. IS0 2073, Aluminium oxide primarily used for the produc- tion of aluminium - Preparation of sample solution for analysis - Method by means of attack by hydrochloric acid under pressure. 3 PRINCIPLE Dissolution of a test portion by heating in a sealed bor
13、osi- licate tube with hydrochloric acid at a controlled tempera- ture of 250 “C. Aspiration of the solution in an air-acetylene flame and determination of manganese by spectrophotometric measurement of the absorption of the 279,5 nm line emitted by a manganese hollow cathode lamp. 4 REAGENTS During
14、the analysis, use only reagents of recognized analytical grade and only water with a conductivity less than or equal to 50 PSlm. 4.1 Hydrochloric acid, p approximately I,19 g/ml, about 12 N solution. 4.2 Aluminium, acid solution (base solution). Pickle 60 g of extra pure aluminium (assay 99,999 %),
15、in the form of shavings obtained by turning or drilling, in a little nitric acid, p approximately I,40 g/ml. Wash the cleaned shavings with water and then dry them by washing with acetone. Weigh, to the nearest 0.02 g, 53.0 g of the dried shavings, place in a beaker of convenient capacity and add 60
16、0 ml of the hydrochloric acid solution (4.1) and 300 ml of water. introduce 1 drop of mercury to facilitate the attack. Wait until the reaction subsides and then place the beaker on a sand bath or hot-plate and heat gently until all the alumin- ium has been dissolved. Add another 120 ml of the hydro
17、- chloric acid solution (4.1). Allow to cool, transfer quantitatively to a 1 000 ml one mark volumetric flask, dilute to the mark and mix. 4.3 Manganese, standard solution, corresponding to 0,500 g of Mn per litre. 1 ml of this standard solution, prepared according to 4.3.1 or 4.3.2, contains 0,000
18、5 g of Mn. 4.3.1 Weigh, to the nearest 0,000 1 g, 1,802 g of manga- nese(ll) chloride tetrahydrate (MnCl,.4H,O), dissolve in water, transfer quantitatively to a 1 000 ml one-mark volu- metric flask, dilute to the mark and mix. 4.3.2 Weigh, to the nearest 0,000 1 g, 0,500 g of manga- nese, extra pure
19、, place in a beaker of convenient capacity (for example 200 ml) and add 6 ml of water and 6 ml of the hydrochloric acid solution (4.1). Cover the beaker with a clock-glass and warm until the manganese has completely dissolved. Cool to ambient temperature and transfer the solution quantitatively to a
20、 1 000 ml one-mark volumetric flask, dilute to the mark and mix. 4.4 Manganese, standard solution, corresponding to 0,010 g of Mn per litre. Place IO,0 ml of the standard manganese solution (4.3) in a 500 ml one-mark volumetric flask, dilute to the mark and mix. 1 ml of this standard solution contai
21、ns 0,010 mg of Mn. 1 Copyright International Organization for Standardization Provided by IHS under license with ISONot for ResaleNo reproduction or networking permitted without license from IHS-,-,-IS0 3390-1976 (El 4.5 Manganese, standard solution, corresponding to 0,001 g of Mn per litre. Place 5
22、0.0 ml of the standard manganese solution (4.4) in a 500 ml one-mark volumetric flask, dilute to the mark and mix. 1 ml of this standard solution contains 0,001 mg of Mn. 5 APPARATUS Ordinary laborator apparatus and : 5.1 Apparatus specified in IS0 2073 (clause 5). 5.2 Atomic absorption spectrophoto
23、meter, fitted with a burner fed by air and acetylene (a 100 mm burner is suitable). 5.3 Manganese hollow cathode lamp. 6 PROCEDURE 6.1 Test portion Weigh, to the nearest 0,001 g, 2,00 g of the dried test sample, prepared according to IS0 802 (sub-clause 3.3). clause 3.3). 6.2 Preparation of calibrat
24、ion graph 6.2.1 Preparation of the standard matching solutions Into each of a series of nine 500 ml one-mark volumetric flasks, place 100 ml of the aluminium base solution (4.2) and then respectively the volumes of the standard manga- nese solutions (4.5 or 4.4) indicated in the following table. Dil
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ISO33901976ALUMINIUMOXIDEPRIMARILYUSEDFORTHEPRODUCTIONOFALUMINIUMDETERMINATIONOFMANGANESECONTENTFLAMEATOMICABSORPTIONMETHOD

链接地址:http://www.mydoc123.com/p-1253352.html