ISO 12468-2-2013 External exposure of roofs to fire - Part 2 Classification of roofs《屋顶外露部分的防火 第2部分 屋顶分类》.pdf
《ISO 12468-2-2013 External exposure of roofs to fire - Part 2 Classification of roofs《屋顶外露部分的防火 第2部分 屋顶分类》.pdf》由会员分享,可在线阅读,更多相关《ISO 12468-2-2013 External exposure of roofs to fire - Part 2 Classification of roofs《屋顶外露部分的防火 第2部分 屋顶分类》.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、 ISO 2013 External exposure of roofs to fire Part 2: Classification of roofs Exposition des toitures un feu extrieur Partie 2: Classification des toitures INTERNATIONAL STANDARD ISO 12468-2 Second edition 2013-11-01 Reference number ISO 12468-2:2013(E) ISO 12468-2:2013(E)ii ISO 2013 All rights reser
2、ved COPYRIGHT PROTECTED DOCUMENT ISO 2013 All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting on the internet or an intranet, without prior writt
3、en permission. Permission can be requested from either ISO at the address below or ISOs member body in the country of the requester. ISO copyright office Case postale 56 CH-1211 Geneva 20 Tel. + 41 22 749 01 11 Fax + 41 22 749 09 47 E-mail copyrightiso.org Web www.iso.org Published in Switzerland IS
4、O 12468-2:2013(E) ISO 2013 All rights reserved iii Contents Page Foreword iv Introduction v 1 Scope . 1 2 Normative references 1 3 Terms and definitions . 1 4 Classification 1 5 Test results 1 6 Field of application 2 6.1 Pitch 2 6.2 Nature of the deck 2 6.3 Level of fire exposure 4 6.4 Extension of
5、 the field of application . 5 7 Classification report . 5 ISO 12468-2:2013(E) Foreword ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through IS
6、O technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates c
7、losely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. The procedures used to develop this document and those intended for its further maintenance are described in the ISO/IEC Directives, Part 1. In particular the different approval criter
8、ia needed for the different types of ISO documents should be noted. This document was drafted in accordance with the editorial rules of the ISO/IEC Directives, Part 2 (see www.iso.org/directives). Attention is drawn to the possibility that some of the elements of this document may be the subject of
9、patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of any patent rights identified during the development of the document will be in the Introduction and/or on the ISO list of patent declarations received (see www.iso.org/patents). Any trade name
10、used in this document is information given for the convenience of users and does not constitute an endorsement. For an explanation on the meaning of ISO specific terms and expressions related to conformity assessment, as well as information about ISOs adherence to the WTO principles in the Technical
11、 Barriers to Trade (TBT) see the following URL: Foreword - Supplementary information The committee responsible for this document is ISO/TC 92 , Fire Safet y , Subcommittee SC 2, Fire containment. This second edition cancels and replaces the previous edition (ISO 12468-2:2005), of which it constitute
12、s a minor revision. ISO 12468 consists of the following parts, under the general title External exposure of roofs to fire: Part 1: Test method Part 2: Classification of roofs The following parts are under preparation: Part 3: Commentaryiv ISO 2013 All rights reserved ISO 12468-2:2013(E) Introduction
13、 This part of ISO 12468 establishes a classification for roofs tested in accordance with ISO 12468-1. The classifications described in this part of ISO 12468 consider the three levels of fire exposure as defined in ISO 12468-1. Level A: A large burning brand coming from an adjacent building and fall
14、ing onto the roof. Level A considers the effects of wind and additional radiant heat. Level B: A medium burning brand coming from a fire in a neighbourhood and falling onto the roof. Level B considers the effect of wind but without additional radiant heat. Level C: A small burning brand transported
15、by the wind from a remote fire and falling onto the roof. Level C considers the effect of wind but without additional radiant heat. ISO 2013 All rights reserved v External exposure of roofs to fire Part 2: Classification of roofs 1 Scope This part of ISO 12468 establishes the classification of roofs
16、 tested in accordance with ISO 12468-1. Performance criteria are established with respect to the following: fire penetration or openings; external fire spread; falling of flaming droplets or debris. 2 Normative references The following documents, in whole or in part, are normatively referenced in th
17、is document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 12468-1, External exposure of roofs to fire Part 1: Test method ISO 13943:2008, F
18、ire safety Vocabulary 3 Terms and definitions For the purposes of this document, the terms and definitions given in ISO 12468-1 and ISO 13943:2008 apply. 4 Classification 4.1 The classification scheme in Table 1 is based on the results of testing a roof in accordance with ISO 12468-1. (Fire exposure
19、s: Level A test conditions include a large burning brand with radiation and wind; Level B test conditions include a medium brand with wind; Level C test conditions include a small brand with wind.) 4.2 Six classes are established in the rank order: A1, A2, B1, B2, C1, and C2 with A1 being the highes
20、t performance. (Level A exposures result in A1 or A2 classes, Level B exposures result in B1 or B2 classes, and Level C exposures result in C1 or C2 classes.) 5 Test results Table 1 gives the test results. INTERNATIONAL ST ANDARD ISO 12468-2:2013(E) ISO 2013 All rights reserved 1 ISO 12468-2:2013(E)
21、 Table 1 Classification scheme Test results Classes A1 A2 B1 B2 C1 C2 Fire penetration or openings None within 30 min None within 15 min None within 30 min None within 15 min None within 30 min None within 15 min External fire spread Does not reach the limits of the measuring zone in any direction w
22、ithin 30 min Does not reach the limits of the measuring zone in any direction within 15 min Does not reach the limits of the measuring zone in any direction within 30 min Does not reach the limits of the measuring zone in any direction within 15 min Does not reach the limits of the measuring zone in
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ISO1246822013EXTERNALEXPOSUREOFROOFSTOFIREPART2CLASSIFICATIONOFROOFS 屋顶 外露 部分 防火 分类 PDF

链接地址:http://www.mydoc123.com/p-1250491.html