ISO 10916-2014 Calculation of the impact of daylight utilization on the net and final energy demand for lighting《照明用最终净能源需求日光利用率影响的计算》.pdf
《ISO 10916-2014 Calculation of the impact of daylight utilization on the net and final energy demand for lighting《照明用最终净能源需求日光利用率影响的计算》.pdf》由会员分享,可在线阅读,更多相关《ISO 10916-2014 Calculation of the impact of daylight utilization on the net and final energy demand for lighting《照明用最终净能源需求日光利用率影响的计算》.pdf(70页珍藏版)》请在麦多课文档分享上搜索。
1、 ISO 2014 Calculation of the impact of daylight utilization on the net and final energy demand for lighting Calcul de leffet dutiliser la lumire du jour la demande nergtique net et finale pour lclairage INTERNATIONAL STANDARD ISO 10916 First edition 2014-06-15 Reference number ISO 10916:2014(E) ISO
2、10916:2014(E)ii ISO 2014 All rights reserved COPYRIGHT PROTECTED DOCUMENT ISO 2014 All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting on the int
3、ernet or an intranet, without prior written permission. Permission can be requested from either ISO at the address below or ISOs member body in the country of the requester. ISO copyright office Case postale 56 CH-1211 Geneva 20 Tel. + 41 22 749 01 11 Fax + 41 22 749 09 47 E-mail copyrightiso.org We
4、b www.iso.org Published in Switzerland ISO 10916:2014(E) ISO 2014 All rights reserved iii Contents Page Foreword iv Introduction v 1 Scope . 1 2 Normative references 1 3 Terms and definitions . 2 4 Symbols, indices, and abbreviated terms . 3 4.1 Symbols . 4 4.2 Indices 5 5 Proof calculation method 5
5、 5.1 Energy demand for lighting as function of daylight 5 5.2 Subdivision of a building into zones . 7 5.3 Operating time. 8 5.4 Artificial lighting 8 5.5 Constant illuminance control . 8 5.6 Daylight 8 5.7 Occupancy dependency factor F O,n. 9 6 Daylight Performance Indicator . 9 Annex A (informativ
6、e) Simple calculation method.10 Annex B (normative) Comprehensive calculation .53 Annex C (informative) Daylight performance indicator 54 Annex D (informative) Examples .55 Bibliography .63 ISO 10916:2014(E) Foreword ISO (the International Organization for Standardization) is a worldwide federation
7、of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. I
8、nternational organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. The procedures used to develop this document and those
9、 intended for its further maintenance are described in the ISO/IEC Directives, Part 1. In particular the different approval criteria needed for the different types of ISO documents should be noted. This document was drafted in accordance with the editorial rules of the ISO/IEC Directives, Part 2 (se
10、e www.iso.org/directives). Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of any patent rights identified during the development of the docu
11、ment will be in the Introduction and/or on the ISO list of patent declarations received (see www.iso.org/patents). Any trade name used in this document is information given for the convenience of users and does not constitute an endorsement. For an explanation on the meaning of ISO specific terms an
12、d expressions related to conformity assessment, as well as information about ISOs adherence to the WTO principles in the Technical Barriers to Trade (TBT) see the following URL: Foreword - Supplementary information The committee responsible for this document is ISO/TC 163, Thermal performance and en
13、ergy use in the built environment, Subcommittee SC 2, Calculation methods.iv ISO 2014 All rights reserved ISO 10916:2014(E) Introduction This International Standard is part of a set of standards allowing to rate the overall energetic performance of buildings. Facades and rooflights have a key impact
14、 on the buildings energy balance. This International Standard supports the daylighting and lighting-energy-related analysis and optimization of facade and rooflight systems. It was therefore specifically devised to establish conventions and procedures for the estimation of daylight penetrating build
15、ings through vertical facades and rooflights, as well as on the energy consumption for electric lighting as a function of daylight provided in indoor spaces. ISO 2014 All rights reserved v Calculation of the impact of daylight utilization on the net and final energy demand for lighting 1 Scope This
16、International Standard defines the calculation methodology for determining the monthly and annual amount of usable daylight penetrating non-residential buildings through vertical facades and rooflights and the impact thereof on the energy demand for electric lighting. This International Standard can
17、 be used for existing buildings and the design of new and renovated buildings. This International Standard provides the overall lighting energy balance equation relating the installed power density of the electric lighting system with daylight supply and lighting controls (proof calculation method).
18、 The determination of the installed power density is not in the scope of this method, neither are controls relating, for instance, to occupancy detection. Provided the determination of the installed power density and control parameters using external sources, the internal loads by lighting and the l
19、ighting energy demand itself can be calculated. The energy demand for lighting and internal loads by lighting can then be taken into account in the overall building energy balance calculations: heating; ventilation; climate regulation and control (including cooling and humidification); heating the d
20、omestic hot-water supply of buildings. For estimating the daylight supply and rating daylight-dependent artificial lighting control systems, a simple table-based calculation approach is provided. The simple method describes the division of a building into zones as required for daylight illumination-
21、engineering purposes, as well as considerations on the way in which daylight supplied by vertical facade systems and rooflights is utilized and how daylight-dependent lighting control systems effect energy demand. Dynamic vertical facades with optional shading and light redirection properties are co
22、nsidered, i.e. allowing a separate optimization of facade solutions under direct insolation and under diffuse skies. For rooflighting systems standard, static solutions like shed rooflights and continuous rooflights are considered. The method is applicable for different latitudes and climates. For s
23、tandard building zones (utilizations), operation times are provided. For detailed computer-based analysis (comprehensive calculation), minimum requirements are specified. To support overall building performance assessment, additional daylight performance indicators on the overall building level are
24、provided. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ISO109162014CALCULATIONOFTHEIMPACTOFDAYLIGHTUTILIZATIONONTHENETANDFINALENERGYDEMANDFORLIGHTING 照明 最终

链接地址:http://www.mydoc123.com/p-1249930.html