IEEE N42 14-1999 en Calibration and Use of Germanium Spectrometers for the Measurement of Gamma-Ray Emission Rates of Radionuclides《放射性核素的γ射线放射率测量用锗能谱仪的校正和使用》.pdf
《IEEE N42 14-1999 en Calibration and Use of Germanium Spectrometers for the Measurement of Gamma-Ray Emission Rates of Radionuclides《放射性核素的γ射线放射率测量用锗能谱仪的校正和使用》.pdf》由会员分享,可在线阅读,更多相关《IEEE N42 14-1999 en Calibration and Use of Germanium Spectrometers for the Measurement of Gamma-Ray Emission Rates of Radionuclides《放射性核素的γ射线放射率测量用锗能谱仪的校正和使用》.pdf(82页珍藏版)》请在麦多课文档分享上搜索。
1、The Institute of Electrical and Electronics Engineers, Inc.345 East 47th Street, New York, NY 10017-2394, USACopyright 1999 by the Institute of Electrical and Electronics Engineers, Inc.All rights reserved. Published 1 June 1999. Printed in the United States of America.Print: ISBN 0-7381-1412-X SH94
2、702PDF: ISBN 0-7381-0740-9 SS94702No part of this publication may be reproduced in any form, in an electronic retrieval system or otherwise, without the prior written permission of the publisher.ANSI N42.14-1999 (R2004)(Revision ofANSI N42.14-1991)American National Standard forCalibration and Use of
3、 Germanium Spectrometers for the Measurement of Gamma-Ray Emission Rates of RadionuclidesSponsorAccredited Standards Committee on Radiation Instrumentation, N42Accredited by theAmerican National Standards InstituteSecretariatThe Institute of Electrical and Electronics Engineers, Inc.Reaffirmed Decem
4、ber 2, 2004American National Standards InstituteAbstract: Methods for the calibration and use of germanium spectrometers for the measurementof gamma-ray energies and emission rates over the energy range from 59 keV to approximately3000 keV, and for the calculation of source activities from these mea
5、surements, are established.Minimum requirements for automated peak finding are stated. Methods for measuring the full-energy peak efficiency with calibrated sources are given. Performance tests that ascertain the prop-er functioning of the Ge spectrometer and evaluate the limitations of the algorith
6、ms used for locatingand fitting single and multiple peaks are described. Methods for the measurement of, and thecorrection for pulse pileup are suggested. Techniques are recommended for the inspection of spec-tral-analysis results for large errors resulting from summing of cascade gamma rays in the
7、detector.Suggestions are provided for the establishment of data libraries for radionuclide identification, de-cay corrections, and the conversion of gamma-ray rates to decay rates.Keywords: calibration, cascade summing, decay rates, gamma-ray emission rates, germaniumspectrometers, radionuclides, sp
8、ectrometersAmerican National StandardAn American National Standard implies a consensus of those substantially concerned with its scopeand provisions. An American National Standard is intended as a guide to aid the manufacturer, theconsumer, and the general public. The existence of an American Nation
9、al Standard does not in anyrespect preclude anyone, whether he has approved the standard or not, from manufacturing, market-ing, purchasing, or using products, processes, or procedures not conforming to the standard. Amer-ican National Standards are subject to periodic reviews and users are cautione
10、d to obtain the latesteditions.CAUTION NOTICE:This American National Standard may be revised or withdrawn at any time.The procedures of the American National Standards Institute require that action be taken to reaf-firm, revise, or withdraw this standard no later than five years from the date of pub
11、lication. Purchas-ers of American National Standards may receive current information on all standards by calling orwriting the American National Standards Institute.Authorization to photocopy portions of any individual standard for internal or personal use isgranted by the Institute of Electrical an
12、d Electronics Engineers, Inc., provided that the appropriatefee is paid to Copyright Clearance Center. To arrange for payment of licensing fee, please contactCopyright Clearance Center, Customer Service, 222 Rosewood Drive, Danvers, MA 01923 USA;(508) 750-8400. Permission to photocopy portions of an
13、y individual standard for educational class-room use can also be obtained through the Copyright Clearance Center.Copyright 1999 IEEE. All rights reserved.iiiIntroduction(This introduction is not part of ANSI N42.14-1999, American National Standard for Calibration and Use of GermaniumSpectrometers fo
14、r the Measurement of Gamma-Ray Emission Rates of Radionuclides.)This standard covers the techniques for the calibration and use of germanium spectrometers for the measure-ment of gamma-ray emission rates of radionuclides to assure the reliability of such measurements.This standard is the responsibil
15、ity of the Accredited Standards Committee N42 on Radiation Instrumenta-tion. Committee N42 delegated the development of the standard to its Subcommittee N42.RM. Drafts werereviewed by members of Committee N42, Subcommittee N42.RM, and other interested parties, and thecomments received were utilized
16、in producing the standard as finally approved and issued. The standard wasapproved by Committee N42 letter ballot of 17 December 1997.ParticipantsAt the time it approved this standard, the Accredited Standards Committee on Radiation Instrumentation,N42, had the following members:Louis Costrell,Chair
17、Michael P. Unterweger, Vice ChairNaeem Ahmad,SecretariatOrganization Represented Name of RepresentativeAmerican Conference of Governmental Industrial Hygienists.Jesse LiebermanApplied Safety Technology.Edward J. Vallario*Battelle Pacific NW Laboratories .Joseph C. McDonaldBicronJoseph G. BellianEber
18、line Instruments .James K. HeschEGb) Coincidence (cascade) summing;c) The decay of the source during sampling (e.g., with air filters) and counting;d) The decay of the source from a previous time to the counting period;e) Attenuation of photons within and external to the source that is not accounted
19、 for by the full-energypeak efficiency calibration.2. ReferencesThis standard shall be used in conjunction with the following publications. When the following standards aresuperseded by an approved revision, the revision shall apply.ANSI N13.30-1996, American National Standard Performance Criteria f
20、or Radiobioassay.3ANSI N42.23-1996, American National Standard Measurement and Associated Instrument Quality Assur-ance for Radioassay Laboratories.4IEEE Std 100-1996, IEEE Standard Dictionary of Electrical and Electronics Terms.5IEEE Std 325-1996, IEEE Standard Test Procedures for Germanium Gamma-R
21、ay Detectors.3ANSI publications are available from the Sales Department, American National Standards Institute, 11 West 42nd Street, 13th Floor,New York, NY 10036, USA (www.ansi.org/).4This publication is available from the Institute of Electrical and Electronics Engineers, 445 Hoes Lane, P.O. Box 1
22、331, Piscataway, NJ08855-1331, USA (www.standards.ieee.org/).5IEEE publications are available from the Institute of Electrical and Electronics Engineers, 445 Hoes Lane, P.O. Box 1331, Piscataway,NJ 08855-1331, USA (www.standards.ieee.org/).ANSIFOR THE MEASUREMENT OF GAMMA-RAY EMISSION RATES OF RADIO
23、NUCLIDES Std N42.14-1999Copyright 1999 IEEE. All rights reserved.33. DefinitionsThe word “shall” denotes a requirement, the word “should” denotes a recommendation, and the word “may”denotes permission. To conform to this standard, Ge spectrometry shall be performed in accordance with therequirements
24、 of this standard, but not necessarily with its recommendations; however, justification should bedocumented for deviations from a recommendation.For the purposes of this standard, the following terms and definitions apply. IEEE Std 100-1996 should bereferenced for terms not defined in this clause.3.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- IEEEN42141999ENCALIBRATIONANDUSEOFGERMANIUMSPECTROMETERSFORTHEMEASUREMENTOFGAMMARAYEMISSIONRATESOFRADIONUCLIDES

链接地址:http://www.mydoc123.com/p-1249331.html