IEEE N42 13-2004 en Calibration and Usage of Dose Calibrator Ionization Chambers for the Assay of Radionuclides《验定放射性核素剂是校准器电离室的校正和使用》.pdf
《IEEE N42 13-2004 en Calibration and Usage of Dose Calibrator Ionization Chambers for the Assay of Radionuclides《验定放射性核素剂是校准器电离室的校正和使用》.pdf》由会员分享,可在线阅读,更多相关《IEEE N42 13-2004 en Calibration and Usage of Dose Calibrator Ionization Chambers for the Assay of Radionuclides《验定放射性核素剂是校准器电离室的校正和使用》.pdf(13页珍藏版)》请在麦多课文档分享上搜索。
1、Published byThe Institute of Electrical and Electronics Engineers, Inc.3 Park Avenue, New York, NY 10016-5997, USA Copyright 2005 by The Institute of Electrical and Electronics Engineers, Inc.No part of this publication may be reproduced in any form, in an electronic retrieval system or otherwise, w
2、ithout the priorwritten permission of the publisher.ANSI N42.13-2004(Revision of ANSI N42.13-1986)American National StandardCalibration and Usage of“Dose Calibrator” Ionization Chambers for the Assay of RadionuclidesNational Committee on Radiation Instrumentation, N42Accredited by the American Natio
3、nal Standards InstituteSecretariatInstitute of Electrical and Electronics Engineers, IncApproved 2 December 2004American National Standards InstituteiiAmerican National StandardAn American National Standard implies a consensus of those substantially concerned with its scope and provisions.An America
4、n National Standard is intended as a guide to aid the manufacturer, the consumer, and the general public.The existence of an American National Standard does not in any respect preclude anyone, whether he has approved thestandard or not, from manufacturing, marketing, purchasing, or using products, p
5、rocesses, or procedures notconforming to the standard. American National Standards are subject to periodic review and users are cautioned toobtain the latest editions.CAUTION NOTICE:This American National Standard may be revised or withdrawn at any time. The procedures ofthe American National Standa
6、rds Institute require that action be taken to reafrm, revise, or withdraw this standard nolater than ve years from the date of publication. Purchasers of American National Standards may receive currentinformation on all standards by calling or writing the American National Standards Institute.iiiFor
7、eword(This Foreword is not a part of ANSI N42.13-1986, American National Standard Calibration and Usage of Dose CalibratorIonization Chambers for the Assay of Radionuclides.)This revised standard is the responsibility of Accredited Standards Committee N42 on Radiation Instrumentation.Committee N42 d
8、elegated the development of the standard to its Subcommittee N42.2. Drafts were reviewed by themembers of Committee N42, Subcommittee N42.2, and by other interested parties. The comments received wereutilized in producing the standard as nally approved and issued. The revised standard was approved b
9、y CommitteeN42 letter ballot of December 30, 1984, with minor modications as submitted to the Committee N42 membership onAugust 29, 1984.At the time it approved this revised standard, the Accredited Standards Committee N42 on Radiation Instrumentationhad the following membership:Louis Costrell, Chai
10、r David C. Cook, Secretary American Chemical Society.(Vacant)American Conference of Governmental Industrial HygienistsJesse LiebermanAmerican Industrial Hygiene Association .(Vacant)American Nuclear Society .Frank ManningAmerican Society of Mechanical Engineers(Vacant)American Society of Safety Engi
11、neers (Vacant)Atomic Industrial Forum(Vacant)Health Physics Society. J. B. Horner KuperJack M. Selby (Alt)Institute of Electrical and Electronics Engineers .Louis CostrellDavid C. Cook (Alt)J. Forster (Alt)A. J. Spurgin (Alt)Instrument Society of America M. T. SlindJ. E. Kaveckis (Alt)Lawrence Berke
12、ley LaboratoryLee J. WagnerOak Ridge National Laboratory.Frank ManningD. J. Knowles (Alt)Scientic Apparatus Makers Association.(Vacant)UCLA Center for the Health Sciences.James E. McLaughlinUS Civil Defense Preparedness Agency Carl R. Siebentritt, JrUS Department of the Army, Materiel Command .Basil
13、 MarkowUS Department of Commerce, National Bureau of Standards Louis CostrellUS Department of Energy Pollutant Characterization and Safety Research Division Gerald GoldsteinUS Nuclear Regulatory Commission.Edward C. Wenzinger, SrivThe membership of Subcommittee N42.2 was as follows:F. X. Masse(Chair
14、man)J. M. Robin Hutchinson, Secretary Ron AlthardtKarl AmlauerJohn H. BuchananRobert BurnsR. F. ColeyBert M. CourseyRod DaytonRoger FerrisJ. FloeckherR. J. GehrkeJames GibbsAllen GoldsteinDonald HamiltonDale HoppesDonald HorrocksA. JarvisDonald S. KearnsStephen M. KimY. KobayashiWilliam MacIntyreW.
15、B. MannGerald Martin, JrDavid V. MaudsleyPaul MurphyRalph NuelleM. J. OestmannJ. RingCarl W. SeidelS. S. YanivvThe following persons were on the balloting committee that approved this document for submission to the AccreditedStandards Committee N42:Joseph G. BellianO. W. Bilharz, JrLouis CostrellDav
16、id C. CookJohn M. Gallagher, JrGerald GoldsteinJ. B. Horner KuperJesse LiebermanFrank ManningBasil MarkowJames E. McLaughlinRichard F. SheaCarl R. Siebentritt, JrM. T. SlindE. J. VallarioLee J. WagnerEdward C. Wenzinger, SrviCLAUSE PAGE1. Introduction.12. Scope.12.1 12.2 13. Definitions and Referenc
17、es .23.1 Definitions 23.2 References 24. Procedure 24.1 General . 24.2 Initial Calibrations 24.3 Standard Sources 34.4 Assay 34.5 Performance Testing 44.6 Accuracy and Reproducibility . 45. Sources of Error 56. Precautions 56.1 Assay of a Radionuclide for Which No Standard or Calibration Setting Is
18、Available 56.2 Nonlinearity Effect. 56.3 Radionuclidic Impurities 66.4 Beta-Particle Emitters 66.5 Low-Energy-Photon Emitters 66.6 Dissolved Gaseous Radionuclides . 66.7 Plate-Out of Radionuclides 76.8 Simulated Sources 7Copyright 1986 IEEE All Rights Reserved1American National StandardCalibration a
19、nd Usage ofDose Calibrator IonizationChambers for the Assay of Radionuclides1. IntroductionThe wide range of calibrator-type instruments currently being used primarily for radionuclide assay in nuclearmedicine indicates the need for a standard for uniformity in measurement and test techniques. Such
20、devices arecomposite systems consisting of an ionization chamber integrally coupled to appropriate electronic circuitry thatconverts the ionization current to a readout in units of activity. The principles of operation of the ionization chamberare well summarized in the NCRP Report No 58 11and will
21、not be repeated here. Wide activity range and stabilityare useful characteristics of ionization chambers in this application. The advantages of this type of system forradionuclide assay include ease of use and interpretation.2. Scope2.1 This standard covers the technique for the quantication of the
22、activity of identied radionuclides using any of avariety of ionization chambers currently available for this purpose. Application of the standard is limited toinstruments that incorporate well-type ionization chambers as detectors.2.2 This standard provides a method for obtaining measurements that a
23、re accurate to within 10% and reproducible towithin 5% usually for sources of more than 100 mCi (3.7 106Bq). The standard is also intended to assurecontinuing performance of the apparatus within these specications. For purposes of this standard, accuracy andreproducibility are described in 4.6.1The
24、numbers in brackets correspond to the references in 3.2.2Copyright 1986 IEEE All Rights ReservedIEEE Std N42.13-1986 AMERICAN NATIONAL STANDARD CALIBRATION AND USAGE OF 3. Definitions and References3.1 Definitionsaccuracy: Accuracy, usually described in terms of overall uncertainty, is the estimate
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- IEEEN42132004ENCALIBRATIONANDUSAGEOFDOSECALIBRATORIONIZATIONCHAMBERSFORTHEASSAYOFRADIONUCLIDES 放射性 核素

链接地址:http://www.mydoc123.com/p-1249330.html