IEEE C37 32-2002 en High-Voltage Switches Bus Supports and Accessories Schedule of Preferred Ratings Construction Guidelines and Specifications《高压开关 总线支架和附件一览表的.pdf
《IEEE C37 32-2002 en High-Voltage Switches Bus Supports and Accessories Schedule of Preferred Ratings Construction Guidelines and Specifications《高压开关 总线支架和附件一览表的.pdf》由会员分享,可在线阅读,更多相关《IEEE C37 32-2002 en High-Voltage Switches Bus Supports and Accessories Schedule of Preferred Ratings Construction Guidelines and Specifications《高压开关 总线支架和附件一览表的.pdf(41页珍藏版)》请在麦多课文档分享上搜索。
1、 The Institute of Electrical and Electronics Engineers, Inc.3 Park Avenue, New York, NY 10016-5997, USACopyright 2003 by the Institute of Electrical and Electronics Engineers, Inc.All rights reserved. Printed in the United States of America.Print:ISBN 0-7381-3604-2 SH95098PDF:ISBN 0-7381-3605-0 SS95
2、098No part of this publication may be reproduced in any form, in an electronic retrieval system or otherwise, without the prior written permission of the publisher.ANSI C37.32-2002(Revision of ANSI C37.32-1996)American National Standard for High Voltage Switches, Bus Supports, and Accessories Schedu
3、les of Preferred Ratings, Construction Guidelines, and SpecificationsApproved 20 March 2002American National Standards Institute, Inc.ANSI C37.32-2002 Copyright 2002 by the National Electrical Manufacturers Association i AMERICAN NATIONAL STANDARD Approval of an American National Standard requires v
4、erification by ANSI that the requirements for due process, consensus, and other criteria for approval have been met by the standards developer. Consensus is established when, in the judgment of the ANSI Board of Standards Review, substantial agreement has been reached by directly and materially affe
5、cted interests. Substantial agreement means much more than a simple majority, but not necessarily unanimity. Consensus requires that all views and objections be considered, and that a concerted effort be made toward their resolution. The use of American National Standards is completely voluntary; th
6、eir existence does not in any respect preclude anyone, whether he has approved the standards or not, from manufacturing, marketing, purchasing, or using products, processes, or procedures not conforming to the standards. The American National Standards Institute does not develop standards and will i
7、n no circumstances give an interpretation of any American National Standard. Moreover, no person shall have the right or authority to issue an interpretation of an American National Standard in the name of the American National Standards Institute. Requests for interpretations should be addressed to
8、 the secretariat or sponsor whose name appears on the title page of this standard. Caution Notice: This American National Standard may be revised or withdrawn at any time. The procedures of the American National Standards Institute require that action be taken periodically to reaffirm, revise, or wi
9、thdraw this standard. Purchasers of American National Standards may receive current information on all standards by calling or writing the American National Standards Institute. Published by National Electrical Manufacturers Association 1300 North 17th Street, Rosslyn, VA 22209 Copyright 2002 by the
10、 National Electrical Manufacturers Association All rights reserved including translation into other languages, reserved under the Universal Copyright Convention, the Berne Convention for the Protection of Literary and Artistic Works, and the International and Pan American Copyright Conventions. No p
11、art of this publication may be reproduced in any form, in an electronic retrieval system or otherwise, without the prior written permission of the publisher. Printed in the United States of America ANSI C37.32-2002 This page intentionally left blank.ANSI C37.32-2002 Copyright 2002 by the National El
12、ectrical Manufacturers Association Contents Page Foreword vi 1 Introduction . 1 1.1 Scope . 1 1.2 References. 1 2 Definitions . 2 3 Station class outdoor air disconnect switches . 2 3.1 Basis of preferred ratings 2 3.2 Preferred ratings . 2 3.3 Dielectric test voltages 3 3.4 Construction specificati
13、ons . 3 4 Distribution class outdoor air disconnect switches. 4 4.1 Basis of preferred ratings. 4 4.2 Preferred ratings . 4 4.3 Dielectric test voltages . 5 4.4 Construction specifications . 5 5 Indoor air switches . 5 5.1 Basis of preferred ratings 5 5.2 Preferred ratings . 6 5.3 Dielectric test vo
14、ltages 6 5.4 Construction specifications . 6 6 Grounding air switches. 7 6.1 Basis of preferred ratings 7 6.2 Preferred ratings . 7 6.3 Electrical clearances . 7 6.4 Corona and radio influence test voltage limits 7 6.5 Construction specifications . 7 7 Fault initiating switches . 8 7.1 Basis of pref
15、erred ratings 8 7.2 Preferred ratings . 8 ANSI C37.32-2002 7.3 Preferred closing time . 8 7.4 Operating life expectancies . 8 7.5 Corona and radio influence test voltage limits 8 7.6 Construction specifications . 8 8 Outdoor, indoor, and enclosed interrupter switches 8 8.1 Basis of preferred ratings
16、 8 8.2 Preferred rated power frequency 8 8.3 Preferred rated voltages. 8 8.4 Preferred rated dielectric withstand . 9 8.5 Preferred rated currents 10 8.6 Preferred rated switching endurance 10 8.7 Preferred rated ice breaking ability 10 8.8 Preferred rated control voltage. 10 8.9 Preferred rated mec
17、hanical operations 11 8.10 Preferred rated terminal loading. 11 8.11 Construction specifications . 11 9 Bus supports . 11 9.1 Insulators 11 9.2 Fittings 11 9.3 Phase spacing 11 10 Switch accessories, operating mechanisms, and switch hooks . 11 10.1 Rated control voltages for power-operated mechanism
18、s. 11 10.2 Hook stick lengths and hook dimensions. 12 Annexes A Reference data 29 B Historical data 31 C Bibliography . 32 Figures 1 Arrangement of bolt holes in terminal pads 27 2 Outdoor air switch hook dimensions . 28 B1 Typical construction classification of station class outdoor air disconnect
19、switches 31 ANSI C37.32-2002 Copyright 2002 by the National Electrical Manufacturers Association Tables 1 Preferred voltage ratings for station class outdoor air switches. 13 2 Preferred switching impulse withstand voltage for station class outdoor air switches 14 3 Preferred continuous and withstan
20、d currents for station class outdoor air switches 14 4 Terminal loadings for high-voltage switches . 15 5 Phase spacing and ground clearance for station class outdoor air switches and bus supports . 16 6 Station class outdoor air switch-pole unit dimensions . 17 7 Station class outdoor air switches
21、preferred mounting hole spacing for 600, 1200, and 1600 ampere switches . 18 8 Preferred voltage ratings for distribution class outdoor air switches . 19 9 Preferred continuous and withstand currents for distribution class outdoor air switches 19 10 Phase spacing and ground clearance for distributio
22、n class outdoor air switches and bus supports . 20 11 Distribution class outdoor air switches - pole unit dimensions 21 12 Preferred voltage ratings for indoor air switches 22 13 Continuous and withstand current for indoor air switches 22 14 Indoor air switches and bus supports-phase spacing and len
23、gth of break 23 15 Grounding switch electrical clearance 24 16 Preferred rated switching currents for interrupter switches. 25 17 Preferred rated control voltages and their ranges 26 ANSI C37.32-2002 Foreword (This Foreword is not part of American National Standard C37.32-2002) The purpose of this r
24、evision is to bring the standard up-to-date and in line with present-day requirements. The standard is coordinated with the other American National Standards in the field of high-voltage switches: ANSI/IEEE C37.30, Standard Requirements for High-Voltage Air Switches IEEE C37.34, Test Code for High-V
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- IEEEC37322002ENHIGHVOLTAGESWITCHESBUSSUPPORTSANDACCESSORIESSCHEDULEOFPREFERREDRATINGSCONSTRUCTIONGUIDELINESANDSPECIFICATIONS

链接地址:http://www.mydoc123.com/p-1249103.html