UL SUBJECT 523-2006 Outline of Investigation for Telephone Service Drop Wire (Issue 2)《电话业务引入线调查大纲 发布编号 2》.pdf
《UL SUBJECT 523-2006 Outline of Investigation for Telephone Service Drop Wire (Issue 2)《电话业务引入线调查大纲 发布编号 2》.pdf》由会员分享,可在线阅读,更多相关《UL SUBJECT 523-2006 Outline of Investigation for Telephone Service Drop Wire (Issue 2)《电话业务引入线调查大纲 发布编号 2》.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNovember 27, 20061SUBJECT 523OUTLINE OF INVESTIGATIONFORTELEPHONE SERVICE DROP WIREIssue Number: 2November 27, 2006Summary of TopicsThis new issue of SU 523 is being issued through ULs electronic
2、publishing system to ensure format uniformity between the PDF andHTML versions of the document. No substantive changes have beenincorporated in the document.The UL Foreword is no longer located within the UL Standard. For informationconcerning the use and application of the requirements contained in
3、 thisStandard, the current version of the UL Foreword is located onULStandardsInfoNet at: http:/ 2006 UNDERWRITERS LABORATORIES INC.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNOVEMBER 27, 2006SUBJECT 5232No Text on This PageUL COPYRIGHTED
4、 MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULCONTENTSGENERAL1 Scope .42 Units of Measurement .4CONSTRUCTION3 Materials and Workmanship 44 Single Pair .44.1 Conductors 44.2 Insulation and jacket 54.3 Single strength member .75 Multiple Pairs .75.1 Conduct
5、ors 75.2 Insulation and jacket 75.3 Support wire .7PERFORMANCE6 Carbon-Arc and Water-Spray Exposure Test .87 Cold Bend Tests 97.1 Cold wind onto cold mandrel .97.2 Unwind after cold soak 98 Heat Shock Test 99 Flow Test .1010 Static Load Test 1011 Impact Test 1112 Crushing Tests .1112.1 Wire between
6、two flat steel plates 1112.2 Wire between one flat plate and a round rod 1113 Dielectric Voltage-Withstand Tests 1213.1 Single-pair wire 1213.2 Multiple-pair wire .1214 Insulation Resistance Tests 1214.1 Single-pair wire 1214.2 Multiple-pair wire .1215 Mechanical Water Absorption Test 1316 Flame Tes
7、t .13MARKINGS17 Wire Markings 1318 Tag, Reel, or Carton Markings .13NOVEMBER 27, 2006 SUBJECT 523 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULGENERAL1 Scope1.1 These requirements cover single-pair and multiple-pair telephone drop wires in
8、tended for use asoverhead conductors that extend telephone circuits (1) from the last utility pole or other outdoor supportto the protector(s) within the building or other structure served, and (2) between buildings or otherstructures on the premises served. These wires are for use in accordance wit
9、h Article 800 of the NationalElectrical Code ( NFPA 70).1.2 These requirements do not cover telephone cable for underground duct applications or direct burial,nor do they cover coaxial telephone cable or distribution wire for telephone service.2 Units of Measurement2.1 In addition to being stated in
10、 the inch/pound units that are customary in the USA, each of therequirements in this outline is also stated in units that make the requirement conveniently usable incountries employing the various metric systems (practical SI and customary). Equivalent although notnecessarily exactly identical resul
11、ts are to be expected from applying a requirement in USA or metricterms. Equipment calibrated in metric units is to be used when a requirement is applied in metric terms.CONSTRUCTION3 Materials and Workmanship3.1 Only materials that are acceptable for the particular use shall be employed in a wire.
12、Wires shall bemade and finished with the degree of uniformity and grade of workmanship that are practicable in awell-equipped factory.3.2 Each material used in a wire shall be compatible with all of the other materials used in the wire.4 Single Pair4.1 Conductors4.1.1 In the integral PVC constructio
13、n containing a single centrally located strength member, two No. 24AWG uncoated solid copper conductors, laid parallel. Otherwise, one pair of No. 18 or 17 AWG solidcopper-coated steel wires, laid parallel, having a nominal conductivity of 30 percent IACS.NOVEMBER 27, 2006SUBJECT 5234UL COPYRIGHTED
14、MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL4.2 Insulation and jacket4.2.1 In the integral construction, the insulation an jacket shall be of PVC or of EPDM rubber. Specimenstaken from the finished wire and tested for physical properties as described in
15、sections 400-480 of theReference Standard for Electrical Wires, Cables, and Flexible Cords, UL 1581 shall comply with Table 4.1(PVC) or 4.2 (EPDM).Table 4.1Physical properties of PVCCondition of specimens at time ofmeasurementMinimum acceptable ultimateelongation (1-in or 25-mm benchmarks)Minimum ac
16、ceptable tensile strengthUnaged 225 percent 1800 lbf/in2or(2-1/4 in or 56.3 mm) 12.4 MN/m2or1240 N/cm2or1.27 kgf/mm2Aged for 168 h in a full-draft circulating-air oven at 100.0 1.0C (212.0 1.8F)60 percent of the result with unagedspecimens85 percent of the result with unagedspecimensTable 4.2Physica
17、l properties of EPDM rubberCondition of specimens at time ofmeasurementMinimum acceptable ultimateelongation (1-in or 25-mm benchmarks)Minimum acceptable tensile strengthUnaged 300 percent 1500 lbf/in2or(3 in or 75 mm) 10.3 MN/m2or1034 N/cm2or1.05 kgf/mm2Aged in an oxygen bomb for 168 h at80.0 1.0C
18、(176.6 1.8F) and agauge pressure of 300 10 lbf/in2or2.07 0.07 MN/m2or 207 7 N/cm2or0.211 0.007 kgf/mm250 percent of the result with unagedspecimens50 percent of the result with unagedspecimensAged in an air bomb for 20 h at 127.01.0C (260.6 1.8F) and a gaugepressure of 80 3 lbf/in2or 0.55 0.02MN/m2o
19、r 55.2 2.1 N/cm2or 0.0560.002 kgf/mm250 percent of the result with unagedspecimens50 percent of the result with unagedspecimens4.2.2 In the nonintegral construction, the insulation shall be of NR (natural rubber) or SBR rubber or ablend of the two and the jacket shall be of neoprene. Specimens taken
20、 from the finished wire and testedfor physical properties as described in sections 400-480 of the Reference Standard for Electrical Wires,Cables, and Flexible Cords, UL 1581 shall comply with Table 4.3 (NR/SBR insulation) and 4.4 (neoprenejacket). In the nonintegral construction, there shall be a gl
21、ass, rayon, cotton or combination braid or wrapover the construction under the jacket.NOVEMBER 27, 2006 SUBJECT 523 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULTable 4.3Physical properties of NR/SBR rubberCondition of specimens attime of
22、measurementMaximum acceptable set inrecovery test (1-in or25-mm bench marksstretched to 3 in or 75 mm)Minimum acceptableultimate elongation (1-in or25-mm bench marks)Minimum acceptable tensilestrengthUnaged 25 percent (1/4 in or 6.2 mm) 350 percent (3-1/2 in or 87.5mm)1500 lbf/in2or10.3 MN/m2or1034
23、N/cm2or1.05 kgf/mm2Aged in an oxygen bomb for96 h at 70.0 1.0C (158.0 1.8F) and a gauge pressureof 300 10 lbf/in2or 2.070.07 MN/mm2or 207 7N/cm2or 0.211 0.007 kgf/mm2Not measured 65 percent of the result with unaged specimens if the sum oftensile plus elongation percentages is at least 140 percent.O
24、therwise 70 percent of the result with unaged specimensTable 4.4Physical properties of neopreneCondition of specimens attime of measurementMaximum acceptable set inrecovery test (1-in or25-mm bench marksstretched to 3 in or 75 mm)Minimum acceptableultimate elongation (1-in or25-mm bench marks)Minimu
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ULSUBJECT5232006OUTLINEOFINVESTIGATIONFORTELEPHONESERVICEDROPWIREISSUE2 电话 业务 引入 调查 大纲 发布 编号 PDF

链接地址:http://www.mydoc123.com/p-1069455.html