UL SUBJECT 4730-2012 OUTLINE OF INVESTIGATION FOR NAMEPLATE DATASHEET AND SAMPLING REQUIREMENTS OF PHOTOVOLTAIC MODULES (Issue 1)《铭牌 数据表和光伏模块的采样要求的调查大纲 (议题1)》.pdf
《UL SUBJECT 4730-2012 OUTLINE OF INVESTIGATION FOR NAMEPLATE DATASHEET AND SAMPLING REQUIREMENTS OF PHOTOVOLTAIC MODULES (Issue 1)《铭牌 数据表和光伏模块的采样要求的调查大纲 (议题1)》.pdf》由会员分享,可在线阅读,更多相关《UL SUBJECT 4730-2012 OUTLINE OF INVESTIGATION FOR NAMEPLATE DATASHEET AND SAMPLING REQUIREMENTS OF PHOTOVOLTAIC MODULES (Issue 1)《铭牌 数据表和光伏模块的采样要求的调查大纲 (议题1)》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULSeptember 14, 20121UL 4730OUTLINE OF INVESTIGATIONFORNAMEPLATE, DATASHEET, AND SAMPLING REQUIREMENTS OFPHOTOVOLTAIC MODULESIssue Number: 1SEPTEMBER 14, 2012Summary of TopicsThis is the first issu
2、e of the Outline of Investigation for Nameplate,Datasheet, and Sampling Requirements of Photovoltaic Modules, whichcovers the required information on the production and measurementtolerances of nameplate rating of flat plate photovoltaic (PV) modules, anddoes not apply to concentrator PV modules. Th
3、is outline identifies fiverating conditions under which the performance parameters of PV modulesshall be reported and a statistical method to determine the number ofsamples required for the power rating measurements.COPYRIGHT 2012 UNDERWRITERS LABORATORIES INC.UL COPYRIGHTED MATERIAL NOT AUTHORIZED
4、FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULSEPTEMBER 14, 2012UL 47302No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULCONTENTS1 Scope .42 General 43 Nameplate .54 Datasheet 65 Sampling .6APPENDIX ASamp
5、le Size (n) Determination(informative)A.1 General .A1A.2 Estimating Standard Deviation “” .A2A.3 Estimating Sample Size “n” .A2SEPTEMBER 14, 2012 UL 4730 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL1 Scope1.1 This outline identifies the r
6、equired information on the production and measurement tolerances ofnameplate rating of flat plate photovoltaic (PV) modules.1.2 This outline identifies five rating conditions under which the performance parameters of PV modulesshall be reported.1.3 This outline identifies a statistical method to det
7、ermine the number of samples required for the powerrating measurements.1.4 The samples shall be drawn at random without regard to their quality as defined in the Standard forSampling procedures and tables for inspection by attributes, ANSI/ASQ Z1.4 (ANSI/ASQ, 2003).1.5 The power rating measurements
8、shall be performed.1.6 This outline requires that the nameplate on the PV module carry the minimum required informationidentified in this outline.1.7 This outline requires that the datasheet supplied by PV module manufacturers carry the minimumrequired information identified in this outline.1.8 Ever
9、y model/type label rating shall be tested to this outline. For the purpose of this outline, amodel/type is defined as modules that have a nameplate rating within 5% of the tested modules inaccordance with this outline.1.9 This outline does not specify annual sampling frequency.1.10 This outline does
10、 not apply to concentrator PV modules.2 General2.1 After accounting for the light induced degradation in accordance with the Standard for CrystallineSilicon Terrestrial Photovoltaic (PV) Modules - Design Qualification and Type Approval, UL 61215 (IEC61215:2005), or the Standard for Thin-Film Terrest
11、rial Photovoltaic (PV) Modules Design Qualificationand Type Approval, UL 61646 (IEC 61646:2008), the measured average power shall be equal to or higherthan the nominal nameplate power rating at STC and no individual module power shall be more than 3%below nominal. These requirements are represented
12、by the following two equations:Pmeasured, average Prated, nominalPmeasured, individual (Prated, nominal 3% production tolerance)Where:Pmeasured, averageis the measured average power of “n” samplesPmeasured, individualis the measured power of individual samplesPmeasured, averageis the independently m
13、easured average power of “1-to-100” samples(n). The number of samples “n” is to be calculated as described in Sampling, Section 5.SEPTEMBER 14, 2012UL 47304UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL2.2 In addition, a minimum of one modul
14、e (more modules may be required as dictated by the purchaseror user) closest to the nominal rated power shall be measured at the other four rating conditions given inthe Standard for Photovoltaic module performance testing and energy rating, IEC 61853-1, (NOCT, LIC,HTC, and LTC). All five rating con
15、ditions are presented in Table 2.1. The nameplate on the individual PVmodules shall carry the minimum information identified in Nameplate, Section 3. Similarly, the datasheetsupplied by the PV module manufacturer shall carry the minimum information identified in Datasheet,Section 4. The number of sa
16、mples used to calculate the measured average power shall be determinedusing the method identified in Sampling, Section 5.Table 2.1Five Rating Conditions as Required by IEC 61853-1Abbreviation Description Irradiance(W/m2)ModuleTemperature(C)AmbientTemperature(C)Wind Speed(m/s)SpectrumHTC Hightemperat
17、ureconditions1000 75 AM 1.5STC Standard testconditions1000 25 AM 1.5NOCT Nominaloperating celltemperatureconditions800 20 1 AM 1.5LTC Low temperatureconditions500 15 AM 1.5LIC Low irradianceconditions200 25 AM 1.53 Nameplate3.1 The nameplate on the individual PV modules shall carry the following min
18、imum information:a) Name and logo of original manufacturer or supplier,b) Type designation and serial number,c) Maximum system voltage,d) Rated nominal power (Pmax) at STC (1000 W/m2, 25C cell temperature, and air mass AM1.5 global spectrum),e) Maximum negative production tolerance (- % or %) of Pma
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ULSUBJECT47302012OUTLINEOFINVESTIGATIONFORNAMEPLATEDATASHEETANDSAMPLINGREQUIREMENTSOFPHOTOVOLTAICMODULESISSUE1

链接地址:http://www.mydoc123.com/p-1069436.html