UL SUBJECT 1680-2003 OUTLINE OF INVESTIGATION FOR STAGE AND LIGHTING CABLES (Issue 1)《舞台和照明电缆的调查大纲 发布编号 1》.pdf
《UL SUBJECT 1680-2003 OUTLINE OF INVESTIGATION FOR STAGE AND LIGHTING CABLES (Issue 1)《舞台和照明电缆的调查大纲 发布编号 1》.pdf》由会员分享,可在线阅读,更多相关《UL SUBJECT 1680-2003 OUTLINE OF INVESTIGATION FOR STAGE AND LIGHTING CABLES (Issue 1)《舞台和照明电缆的调查大纲 发布编号 1》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、November 18, 20031SUBJECT 1680OUTLINE OF INVESTIGATIONFORSTAGE AND LIGHTING CABLESIssue Number 1November 18, 2003Summary of TopicsThis outline is being issued to update and replace the productdescription, ratings, and test programs for single- and multiple-conductorstage and lighting cables in ULs S
2、ubject 1680 bulletin dated December11, 1992.COPYRIGHT 1992, 2003 UNDERWRITERS LABORATORIES INC.NOVEMBER 18, 2003SUBJECT 16802No Text on This PageCONTENTSFOREWORD 4INTRODUCTION1 Scope .5SINGLE-CONDUCTOR CABLES2 Construction 53 Surface Markings .64 Tag Markings .65 Test Program .7MULTIPLE-CONDUCTOR CA
3、BLES6 Construction 87 Surface Markings 108 Tag Markings 109 Test Program 10NOVEMBER 18, 2003 SUBJECT 1680 3FOREWORDA. This Outline of Investigation contains basic requirements for products covered by UnderwritersLaboratories Inc. (UL) under its Follow-Up Service for this category within the limitati
4、ons given below andin the Scope section of this Outline of Investigation. They are subject to revision as further experience andinvestigation may show is necessary or desirable.B. The observance of these requirements by a manufacturer is one of the conditions of the continuedcoverage of the manufact
5、urers product.C. A product which complies with the text of this Outline of Investigation will not necessarily be judged tocomply with the Outline of Investigation if, when examined and tested, it is found to have other featureswhich impair the level of safety contemplated by these requirements.D. A
6、product employing materials or having forms of construction which conflict with specific requirementsof the Outline of Investigation cannot be judged to comply with the Outline of Investigation. A productemploying materials or having forms of construction not addressed by this Outline of Investigati
7、on may beexamined and tested according to the intent of the requirements and, if found to meet the intent of thisOutline of Investigation, may be judged to comply with the Outline of Investigation.E. UL, in performing its functions in accordance with its objectives, does not assume or undertake todi
8、scharge any responsibility of the manufacturer or any other party. The opinions and findings of ULrepresent its professional judgement given with due consideration to the necessary limitations of practicaloperation and state of the art at the time the Outline of Investigation is processed. UL shall
9、not beresponsible to anyone for the use of or reliance upon this Outline of Investigation by anyone. UL shall notincur any obligation or liability for damages, including consequential damages, arising out of or inconnection with the use, interpretation of, or reliance upon this Outline of Investigat
10、ion.F. Many tests required by the Outline of Investigations of UL are inherently hazardous and adequatesafeguards for personnel and property shall be employed in conducting such tests.NOVEMBER 18, 2003SUBJECT 16804INTRODUCTION1 Scope1.1 This Outline covers single- and multiple-conductor stage and li
11、ghting cables for use in accordancewith Articles 520, 525, and 530 and other applicable parts of the National Electrical Code (NEC), NFPA70.SINGLE-CONDUCTOR CABLES2 Construction2.1 Single-conductor cable shall be 8 AWG 250 kcmil in size. The conductor in82AWGcables shallbe of flexible-stranded coppe
12、r using 36 30 AWG strands as specified in UL 62. The conductor in 1 AWG 250 kcmil cables shall be of ASTM Class K or M stranded copper that is, of rope-layconcentric-stranded copper using 30 or 34 AWG strands.2.2 The conductor shall be covered with integral insulation and jacket or with insulation a
13、nd a separable,nonintegral jacket. In each case, the material(s) and thicknesses shall be for 600 volts and a maximumdry temperature rating of 60, 75, 90, or 105C and an optional wet rating of 60 or 75C. The ampacity ofthese cables shall be as assigned for the temperature rating in NEC Table 400.5(B
14、). Cables rated for105C are not intended to carry currents exceeding the values in NEC Table 400.5(B) for 90C.2.3 The average and point thicknesses of nonintegral insulation and jacket shall not be less thanindicated in Table 2.1.Table 2.1Thicknesses of insulation and jacket in single-conductor noni
15、ntegral cableSize of conductorMinimum average thickness in mils Minimum thickness at any point in milsInsulation Jacket Insulation Jacket8 AWG 60 75 54 606 2 60 95 54 761 4/0 80 95 72 76250 kcmil 95 95 85 762.4 The average and point thicknesses required for integral insulation and jacket are based o
16、n thetest-program performance of the cable, with emphasis on the crushing, impact, and abrasion tests (thesetests are described in itemsDGof5.1andeach is marked with an asterisk). Thicknesses are basedon performance but, in no case, shall the thicknesses be less than the values indicated in Table 2.
17、2.NOVEMBER 18, 2003 SUBJECT 1680 5Table 2.2Thicknesses of insulation and jacket in single-conductor integral cableSize of conductor Minimum average thickness in mils Minimum thickness at any point in mils8 AWG 60 546 2 60 541 4/0 80 72250 kcmil 95 853 Surface Markings3.1 The surface markings shall b
18、e as follows:a) Identification of the organization responsible for the product.b) One of the NEC Types SC, SCT,orSCE. Use of the word Type is optional.c) The AWG or kcmil size of the conductor.d) The temperature rating if higher than 60C. In addition, for 105C cable: Max amps NECTable 400.5(B) for 9
19、0C.e) 600 V or 600 volts.f) Water Resistant, followed by temperature rating, if applicable.g) 50C, 60C,or70C if applicable. 40C is acceptable but not required.h) Oil Resistant 60C or Oil Resistant 75C if applicable.4 Tag Markings4.1 The tag markings shall be surface marking itemsahof3.1plus the foll
20、owing:i) The date of manufacture by month and year.j) For use in accordance with Articles 520, 525, and 530 of the National Electrical Code.NOVEMBER 18, 2003SUBJECT 168065 Test Program5.1 The test program is as follows:A) DETAILED EXAMINATION.B) PHYSICAL PROPERTIES Values for the material(s) as stat
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ULSUBJECT16802003OUTLINEOFINVESTIGATIONFORSTAGEANDLIGHTINGCABLESISSUE1 舞台 照明 电缆 调查 大纲 发布 编号 PDF

链接地址:http://www.mydoc123.com/p-1069186.html