UL SUBJECT 1389-2018 UL Outline for Investigation Plant Oil Extraction Equipment (Issue 3).pdf
《UL SUBJECT 1389-2018 UL Outline for Investigation Plant Oil Extraction Equipment (Issue 3).pdf》由会员分享,可在线阅读,更多相关《UL SUBJECT 1389-2018 UL Outline for Investigation Plant Oil Extraction Equipment (Issue 3).pdf(28页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULJUNE 18, 20181UL 1389Outline of Investigation for Plant Oil Extraction EquipmentIssue Number: 3June 18, 2018Summary of TopicsThis third issue of the Outline of Investigation for Plant Oil Extract
2、ionEquipment, UL 1389, covers the expansion of the scope to includeprefabricated plant oil extractioon booths, in addition to the closed looppneumatically operated plant oil extraction equipment currently covered.Also, the instruction manual requirements for plant oil extractors isclarified.ULs Outl
3、ines of Investigation are copyrighted by UL LLC. Neither a printed norelectronic copy of an Outline of Investigation should be altered in any way. All ofULs Outlines of Investigation and all copyrights, ownerships, and rights regardingthose Outlines of Investigation shall remain the sole and exclusi
4、ve property of ULLLC.COPYRIGHT 2018 UL LLCUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULJUNE 18, 2018UL 13892No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULCONTENT
5、SINTRODUCTION1 Scope .52 Units of Measurement .63 Undated References 64 Components 6PART I PLANT OIL EXTRACTORSCONSTRUCTION5 General 66 Containers .77 Pipings and Fittings .78 Gauges 89 Power-Operated Pumps and Bypass Valves .810 Meters 811 Valves 911.1 General 911.2 Safety relief valves 911.3 Exces
6、s flow/backflow/check valves .1111.4 Hydrostatic relief valves .1211.5 Positive shutoff valves 1212 Electric Heater .1213 Lighting 1314 Regulators .1315 Tube Fittings .1316 Flexible Metallic Hose .13PERFORMANCE17 Deformation Test .1318 Leakage Test Pump .1419 Endurance Test 1419.1 Pump .1419.2 Press
7、ure vessel 1520 Leakage Test System .1521 Hydrostatic Strength Test 1522 Mechanical Strength Tests for Slight Glass 1623 Overflow Test 1624 Temperature Test .1725 Tests for Synthetic Rubber Parts .1825.1 General .1825.2 Volume change test 1825.3 Weight loss test 1926 Low Temperature Test 20MANUFACTU
8、RING AND PRODUCTION TESTS27 General 20JUNE 18, 2018 UL 1389 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULMARKINGS28 Details .20INSTRUCTIONS29 Manual 22PART II PREFABRICATED PLANT OIL EXTRACTION BOOTHS30 General 2431 Area Classification 253
9、2 Key Factors Investigated 2533 Field Assembly, Installation and Use 2634 Markings .2735 Instructions 27JUNE 18, 2018UL 13894UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULINTRODUCTION1 Scope1.1 These requirements cover commercial or industri
10、al plant oil extraction equipment for installation inaccordance with ANSI/NFPA 70, National Electrical Code (NEC), the International Fire Code, andANSI/NFPA 1, Fire Code, together with the manufacturers installation instructions.1.2 This plant oil extraction equipment includes:a) Plant oil extractor
11、s These plant oil extractors are complete closed loop pneumaticallyoperated equipment, with electrical features such as for heating, cooling and illumination. Thisequipment has a maximum capacity of 60 gallons (227 L) of plant oil, and uses butane orLP-Gas to extract the plant oils as indicated in t
12、he instruction manual provided with each unit.Installation may be in a distinct room that is part of a commercial or industrial building, or in aprefabricated plant oil extraction booth.b) Prefabricated plant oil extraction booths These prefabricated booths (including modifiedshipping containers, or
13、 “pods”) are for installation in a distinct room that is part of a commercialor industrial building, and incorporate the following attributes:1) The area within these booths is classified as a Class I, Division 1 hazardous locationin accordance with the NEC, and the area outside these booths around
14、openings isclassified as a Class I, Division 2 hazardous location for a distance of 3 ft (0.9 m) in alldirections in accordance with the NEC.2) The plant oil extraction equipment enclosed by these booths use solvents such asliquid butane or liquid propane.3) These booths are provided with integral e
15、lectrical equipment and factory-providedinterconnections for electrical equipment that are suitable for the area classification.4) This integral equipment may include control panels, power distribution, illumination,ventilation, vapor detection/alarming equipment, and fire extinguishing equipment, a
16、sapplicable.5) Suitable ingress/egress are provided for authorized personnel to operate, serviceand maintain the intended plant oil extraction process equipment enclosed by thebooths.c) Plant oil extraction systems Plant oil extraction systems involve any combination of plantoil extraction equipment
17、 needed for the overall extraction process.1.3 These products, when intended for installation in hazardous (classified) locations are markedaccordingly.JUNE 18, 2018 UL 1389 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL1.4 The requirements
18、 in this outline do not cover the physiological or other attributes or effects that mayresult from the use of this equipment.2 Units of Measurement2.1 Values stated without parentheses are the requirement. Values in parentheses are explanatory orapproximate information.3 Undated References3.1 Any un
19、dated reference to a code or standard appearing in the requirements of this outline shall beinterpreted as referring to the latest edition of that code or standard.4 Components4.1 Except as indicated in 4.2, a component of a product covered by this standard shall comply with therequirements for that
20、 component.4.2 A component is not required to comply with a specific requirement that:a) Involves a feature or characteristic not required in the application of the component in theproduct covered by this outline, orb) Is superseded by a requirement in this outline.4.3 A component shall be used in a
21、ccordance with its rating established for the intended conditions ofuse.4.4 Specific components are incomplete in construction features or restricted in performance capabilities.Such components are intended for use only under limited conditions, such as certain temperatures notexceeding specified li
22、mits, and shall be used only under those specific conditions.PART I PLANT OIL EXTRACTORSCONSTRUCTION5 General5.1 Plant oil extraction equipment include the gas container, integral supports, and the necessary corecomponents that allow the system to function as intended and in accordance with the inst
23、allationinstructions. Plant oil extraction equipment fabricated of individual core components shall comply with therequirements of this outline.5.2 All plant oil extraction equipment shall have a maximum pressure rating of 350 psig (2.4 MPa). Theseratings apply as indicated to all parts of the syste
24、m unless otherwise noted in this outline.JUNE 18, 2018UL 13896UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL6 Containers6.1 A container shall be constructed, tested, inspected and marked to indicate compliance with the ASMEBoiler and Pressur
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ULSUBJECT13892018ULOUTLINEFORINVESTIGATIONPLANTOILEXTRACTIONEQUIPMENTISSUE3PDF

链接地址:http://www.mydoc123.com/p-1069170.html