UL 753-2013 UL Standard for Safety Alarm Accessories for Automatic Water-Supply Control Valves for Fire Protection Service (Eighth Edition Reprint with revisions through and includ.pdf
《UL 753-2013 UL Standard for Safety Alarm Accessories for Automatic Water-Supply Control Valves for Fire Protection Service (Eighth Edition Reprint with revisions through and includ.pdf》由会员分享,可在线阅读,更多相关《UL 753-2013 UL Standard for Safety Alarm Accessories for Automatic Water-Supply Control Valves for Fire Protection Service (Eighth Edition Reprint with revisions through and includ.pdf(36页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 753 Alarm Accessories for Automatic Water-Supply Control Valves for Fire Protection ServiceUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION
2、FROM ULUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Alarm Accessories for Automatic Water-Supply Control Valves for Fire Protection Service, UL 753 Eighth Edition, Dated October 25, 2013 Summary of Topics This n
3、ew edition of UL 753 has been published to reect the rst time ANSI approval of the Standard. The requirements are substantially in accordance with Proposal(s) on this subject dated August 9, 2013. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or tr
4、ansmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness
5、 for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL represent
6、ative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless fr
7、om and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. The requirements in this Standard are now in effect, exc
8、ept for those paragraphs, sections, tables, gures, and/or other elements of the Standard having future effective dates as indicated in the note following the affected item. The prior text for requirements that have been revised and that have a future effective date are located after the Standard, an
9、d are preceded by a SUPERSEDED REQUIREMENTS notice. OCTOBER 25, 2013 UL 753 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL OCTOBER 25, 2013 UL 753 tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
10、 DISTRIBUTION WITHOUT PERMISSION FROM UL OCTOBER 25, 2013 1 UL 753 Standard for Alarm Accessories for Automatic Water-Supply Control Valves for Fire-Protection Service First Edition November, 1967 Second Edition July, 1971 Third Edition March, 1976 Fourth Edition October, 1982 Fifth Edition August,
11、1989 Sixth Edition July, 1995 Seventh Edition May, 2004 Eighth Edition October 25, 2013 This ANSI/UL Standard for Safety consists of the Eighth Edition. The most recent designation of ANSI/UL 753 as an American National Standard (ANSI) occurred on October 25, 2013. ANSI approval for a standard does
12、not include the Cover Page, Transmittal Pages, Title Page, or effective date information. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System
13、 (CSDS) at http:/. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. COPYRIGHT
14、 2013 UNDERWRITERS LABORATORIES INC. ANSI/UL 753-2013UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL OCTOBER 25, 2013 UL 753 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMIS
15、SION FROM UL CONTENTS INTRODUCTION 1 Scope .5 2 Components 5 3 Units of Measurement .6 4 Undated References 6 5 Glossary .6 CONSTRUCTION 6 Adjustment and Stops .6 7 Calibration Means .7 8 Tampering Protection 7 9 Materials .8 10 Assembly .8 11 Threaded Openings 8 12 Operating Mechanisms .9 13 Water
16、Motors 9 14 Gong and Gong Protection 9 15 Strainers .10 16 Enclosures .10 17 Corrosion Protection 12 18 Mounting 12 19 Supply Connections .13 20 Field Wiring Connections 14 21 Leads .14 22 Terminals 14 23 Wiring Space .15 24 Interconnection of Units .15 25 Internal Wiring 16 26 Switches .17 27 Mercu
17、ry-Tube Switches 17 28 Insulating Material 17 29 Current Carrying Parts 18 30 Grounding and Bonding .18 31 Spacings 18 32 Servicing Protection .20 PERFORMANCE 33 General 20 34 Water Operated Accessories Test 21 34.1 Response .21 34.2 Endurance 21 34.3 Intensity of alarm .21 35 Pressure Actuated Acce
18、ssory Test 23 35.1 Sensitivity .23 35.2 Strength of parts .23 36 Elastomeric Parts Test 25 37 Overload Test 25 OCTOBER 25, 2013 UL 753 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 38 Endurance Test 26 39 Dielectric Voltage-Withstand Test
19、 .26 40 Short Circuit Test .27 41 Strain-Relief Tests 27 41.1 Flexible cords 27 41.2 Field supply or internal leads 27 42 Push-Back Relief Test .28 43 Corrosion Tests 28 43.1 General .28 43.2 Hydrogen sulde .28 43.3 Sulfur dioxide-carbon dioxide 28 MANUFACTURING AND PRODUCTION TESTS 44 General 29 MA
20、RKINGS 45 General 29 46 Cautionary And Warning .30 INSTRUCTIONS 47 General 30 APPENDIX A Standards for ComponentsA1 OCTOBER 25, 2013 UL 753 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL INTRODUCTION 1 Scope 1.1 These requirements cover al
21、arm accessories for automatic water-supply control valves for use in automatic sprinkler equipment for re protection service. Accessories may include water motors and gongs, pressure-operated switches, and other electrical and nonelectrical attachments, components, or units commonly used with alarm,
22、 dry-pipe and pre-action valves. 1.2 Requirements for the installation and use of alarm accessories with automatic water-supply control valves are included in the Standard for Installation of Sprinkler Systems, NFPA 13. 1.3 The electrical alarm accessories for automatic water-supply control valves a
23、re intended for re-protective signaling use in ordinary locations in accordance with the National Electrical Code, ANSI/NFPA 70. 2 Components 2.1 Except as indicated in 2.2, a component of a product covered by this standard shall comply with the requirements for that component. See Appendix A for a
24、list of standards covering components generally used in the products covered by this standard. 2.2 A component is not required to comply with a specic requirement that: a) Involves a feature or characteristic not required in the application of the component in the product covered by this standard, o
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL7532013ULSTANDARDFORSAFETYALARMACCESSORIESFORAUTOMATICWATERSUPPLYCONTROLVALVESFORFIREPROTECTIONSERVICEEIGHTHEDITIONREPRINTWITHREVISIONSTHROUGHANDINCLUDPDF

链接地址:http://www.mydoc123.com/p-1068898.html