UL 20 CRD-2013 UL Standard for Safety General-Use Snap Switches - Section Paragraph Reference Para 2 10 1 Sections 4 4 4 5 3 5 2 10 5 28 7 1 Tables 5 28 1 Figures 5 28 1 5 28 2 Su.pdf
《UL 20 CRD-2013 UL Standard for Safety General-Use Snap Switches - Section Paragraph Reference Para 2 10 1 Sections 4 4 4 5 3 5 2 10 5 28 7 1 Tables 5 28 1 Figures 5 28 1 5 28 2 Su.pdf》由会员分享,可在线阅读,更多相关《UL 20 CRD-2013 UL Standard for Safety General-Use Snap Switches - Section Paragraph Reference Para 2 10 1 Sections 4 4 4 5 3 5 2 10 5 28 7 1 Tables 5 28 1 Figures 5 28 1 5 28 2 Su.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared and published by Underwriters Laboratories Inc.(UL). It is normative for the a
2、pplicable UL Product Certification Program(s); however, it is currently notpart of the UL Standard(s) referenced below.Product Category (CCN): WMUZStandard Number: UL 20Standard Title: Standard for General-Use Snap SwitchesEdition Date: May 10, 2010Edition Number: 13Section / Paragraph Reference: Pa
3、ra. 2.10.1, Sections 4.4, 4.5.3, 5.2.10, 5.28, 7.1,Tables 5.28.1, Figures 5.28.1, 5.28.2Subject: Flush Switches Employing A Combination Wire Binding/Pressure-TypeTerminal ConstructionDECISION:This CRD documents the requirements for a new terminal design.The terminal consists of a traditionalwire bin
4、ding screw that is machined to employ an integrally formed pressure ring. The pressure ringresembles a screw and washer type design. This integrally formed pressure ring enables the flush switchto be wired as a back-wired terminal, accepting multiple conductors captured under the integrally formedpr
5、essure ring. The body of the switch is also modified to include integrally molded channels/guidesnecessary to: (1) properly position each individual conductor, and, (2) provide a mechanical means toprevent the conductor from being pushed away from under the terminal ring.(NEW) 2.10.1 TERMINAL, COMBI
6、NATION WIRE BINDING/PRESSURETYPE A wire binding screwwith an integrally machined pressure ring. Pressure ring terminals accept both single and multipleconductors that are captured under the machine formed pressure ring. These terminals may be wired witha single conductor using the conventional 3/4 l
7、oop around the wire-binding screw.4 Construction4.4 Bases and Bodies(New) 4.4.1.4 The body of switch employing a combination wire binding/pressure-type terminal shallemploy integrally formed channels/guides within the body to:a) Properly position individual conductor, andb) Provide a means to reduce
8、 the likelihood of the conductor(s) being displaced from under theterminal ring when conductor(s) are installed.Compliance is determined by the Combination Wire Binding/Pressure-Type Terminal Assembly Testdescribed in Section 5.28.4.5.3 Terminals and Leads(New) 4.5.3.7.1 Switches employing a combina
9、tion wire binding/pressure-type terminal shall be limited to10, 12 or 14 AWG conductors. The terminals shall comply with the applicable performance requirementsas specified in UL 486E. See also 1.10 for terminals intended for use with aluminum conductors.5.2 Test SequenceUL COPYRIGHTED MATERIAL NOT
10、AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL(Revised) 5.2.10 AC only flush switch testingReferencea) Contact gap 5.13.1.2b) Overload 5.6.8 - 5.6.12c) Endurance No. 1 (resistive) 5.7.6d) Endurance No. 2 (inductive) 5.7.7e) Endurance No. 3 (tungsten) 5.7.8f) Temperatur
11、e 5.8.1g) Contact gap (repeated) 5.13.1.2h) Dielectric 5.9.1i) Security of leads 5.10j) Pull-out/push-in terminals 5.11.1, 5.11.2k) Temperature/push-in terminals 5.11.3 - 5.11.8l) Effect of heat on actuating members 5.12m) Resistance to heat (70C) 5.17n) Combination Wire Binding/Pressure-Type Termin
12、al Assembly 5.28(New) 5.28 Combination Wire Binding/Pressure-Type Terminal Assembly Test(New) 5.28.1 A flush switch employing a combination wire binding/pressure-type terminals shall notexhibit:a) Damage to the switch, including but not limited to breakage of the housing, or stripping ofthe terminal
13、, andb) Visible displacement of the conductors following the pull test described in 5.28.5.(New) 5.28.2 A flush switch employing a combination wire binding/pressure-type terminal shall be wiredas outlined in Table 5.28.1.STANDARD NUMBER: UL 20 -2-UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER RE
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL20CRD2013ULSTANDARDFORSAFETYGENERALUSESNAPSWITCHESSECTIONPARAGRAPHREFERENCEPARA2101SECTIONS44453521052871TABLES5281FIGURES52815282SUPDF

链接地址:http://www.mydoc123.com/p-1067760.html