《UL 1993 CRD-2016 UL Standard for Safety Self-Ballasted Lamps and Lamp Adapters - Section Paragraph Reference 6 2 2 8 19 Subject Evaluation of tack-soldered electrical connections .pdf》由会员分享,可在线阅读,更多相关《UL 1993 CRD-2016 UL Standard for Safety Self-Ballasted Lamps and Lamp Adapters - Section Paragraph Reference 6 2 2 8 19 Subject Evaluation of tack-soldered electrical connections .pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUL LLC CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared by UL LLC. It is normative for the applicable ULProduct Certification Program(s); however, it is curre
2、ntly not part of the UL Standard(s) referencedbelow.Product Category (CCN): OOLR, OOLVStandard Number: UL 1993Standard Title: Standard for Self-ballasted Lamps and Lamp AdaptersEdition Date: December 4, 2012Edition Number: 4Section / Paragraph Reference: 6.2.2, 8.19Subject: Evaluation of tack-solder
3、ed electrical connectionsDECISION:6.2.2 Where loosening or breaking of electrical connections involves a risk of fire or electric shock, theconnections shall be soldered, welded, or otherwise securely connected. A soldered joint shall bemechanically secure before soldering. A surface mount component
4、 not exceeding a maximum dimensionof 13 mm (0.5 in) need not comply with this requirement. Soldered joints that comply with 8.19 areconsidered to comply with this requirement.8.19 Evaluation of tack-soldered electrical connections8.19.1 Part A Loose connection8.19.1.1 To determine if a cracked or ot
5、herwise unreliable solder joint is capable of hazardous arcing, theconnection in question shall be subjected to the Arcing Test described in Supplement SD of UL 935,Standard for fluorescent ballasts.8.19.1.2 For the test, the conductor to the soldered joint shall be cut and connected to the arcing t
6、ester.If needed, wire with the same or larger gauge may be used to extend the conductors just enough tosecure to the testers wiring terminals.8.19.1.3 Three samples of each connection shall be tested in this fashion. The test results are consideredacceptable if they comply with SD2.1.1 in UL 935.8.1
7、9.2 Part B Random contact8.19.2.1 To determine if a loose conductor could cause a hazardous condition by contacting nearbysurfaces or electrical components, the conductor in question shall be disconnected from the solder jointand connected in turn to the various conductive surfaces and electrical co
8、mponents which it can physicallytouch should its soldered connection fail.8.19.2.2 As these are considered abnormal conditions, this is conducted under the same conditions as theLED lamp and driver abnormal conditions tests in SA8.22.8.19.2.3 The test results are considered acceptable if they do not
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL1993CRD2016ULSTANDARDFORSAFETYSELFBALLASTEDLAMPSANDLAMPADAPTERSSECTIONPARAGRAPHREFERENCE622819SUBJECTEVALUATIONOFTACKSOLDEREDELECTRICALCONNECTIONSPDF

链接地址:http://www.mydoc123.com/p-1067745.html