UL 1977 CRD-2017 UL Standard for Safety Component Connectors for Use in Data Signal Control and Power Applications - Section Paragraph Reference 1 2 10 2 1 11 2 Figure 1 1 Tables .pdf
《UL 1977 CRD-2017 UL Standard for Safety Component Connectors for Use in Data Signal Control and Power Applications - Section Paragraph Reference 1 2 10 2 1 11 2 Figure 1 1 Tables .pdf》由会员分享,可在线阅读,更多相关《UL 1977 CRD-2017 UL Standard for Safety Component Connectors for Use in Data Signal Control and Power Applications - Section Paragraph Reference 1 2 10 2 1 11 2 Figure 1 1 Tables .pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared by UL LLC. It is normative for the applicable ULProduct Certification Program(
2、s); however, it is currently not part of the UL Standard(s) referencedbelow.Product Category (CCN): ECBT2Standard Number: UL 1977Standard Title: Standard for Component Connectors for Use in Data, Signal, Controland Power ApplicationsEdition Date: January 7, 2016Edition Number: 3Section / Paragraph R
3、eference: 1.2, 10.2.1, 11.2, Figure 1.1, Tables 11.1 and 12.1Subject: Connectors rated for 1000 VoltDECISION:1.2 These requirements apply to devices categorized as follows (See Figure 1.1):a) Type 0 rated less than 8.3 A and less than 30 V rms (42 V peak);b) Type 1A rated less than 8.3 A and from 30
4、 V up to and including 600 V ac or dc, or both;c) Type 1B rated from 8.3 A up to and including 200 A, and less than 30 V rms (42 V peak);d) Type 2 rated from 8.3 A to less than 31 A and from 30 V up to and including 600 V ac or dcor both;e) Type 3 rated from 31 A up to and including 200 A and from 3
5、0 V up to and including 600 Vac or dc, or both;f) Type 3A rated from 31 A up to and including 200 A and from 601 V up to and including 1000V ac or dc, or both;g) Type 4 rated from greater than 200 A up to and including 1000 A, and up to and including600Vacordc;h) Type 4A rated greater than 200 A up
6、to and including 1000 A, and from 601 V up to andincluding 1000 V ac or dc.i) Type 5 rated less than 31 A and from 601 V up to and including 6000 V ac or dc, or both.Type designations used in this Standard only serve as a guide to determine appropriate requirements, anddo not represent an assigned r
7、ating. A device without an assigned current rating is considered to be eithera Type 0 or Type 1A depending upon the assigned voltage rating.This is generated text for figtxt.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL10.2 Accessibility of
8、 live parts10.2.1 A connector of Types 1A, 2, 3, 3A, 4 or 4A intended for usage external to the end equipment shallhave live parts protected against exposure to contact by persons when assembled, installed and matedas intended, as determined by the use of the probe shown in Figure 10.1.10.2.2 Mating
9、 devices of Types 1A, 2, 3, 3A, 4 or 4A intended for usage external to the end equipmentshall not have exposed live contacts during engagement or withdrawal as determined by the use of theprobe shown in Figure 10.1.11 Spacings11.1 For devices as specified in Table 11.1 there shall be a minimum spaci
10、ng through air and over surfaceof 1.2 mm (3/64 inch) for a device rated 250 volts or less, and a minimum of 3.2 mm (1/8 inch) for a devicerated more than 250 volts, between an uninsulated live part and:a) An uninsulated live part of opposite polarity;b) An uninsulated grounded metal part; orc) A non
11、-current carrying metal part that is exposed to contact by persons when the device isinstalled and used in the intended manner.Exception: Spacings less than those specified are permitted if the device complies with the requirementsin the Dielectric Voltage-Withstand Test, Section 17.Figure 1.1Connec
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL1977CRD2017ULSTANDARDFORSAFETYCOMPONENTCONNECTORSFORUSEINDATASIGNALCONTROLANDPOWERAPPLICATIONSSECTIONPARAGRAPHREFERENCE121021112FIGURE11TABLESPDF

链接地址:http://www.mydoc123.com/p-1067731.html