《UL 142A-2018 UL Standard for Safety Special Purpose Aboveground Tanks for Specific Flammable or Combustible Liquids (First Edition).pdf》由会员分享,可在线阅读,更多相关《UL 142A-2018 UL Standard for Safety Special Purpose Aboveground Tanks for Specific Flammable or Combustible Liquids (First Edition).pdf(29页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 142A Special Purpose Aboveground Tank for Specic Flammable or Combustible Liquids STANDARD FOR SAFETYUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT P
2、ERMISSION FROM ULUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Special Purpose Aboveground Tank for Specic Flammable or Combustible Liquids, UL 142A First Edition, Dated May 25, 2018 SUMMARY OF TOPICS This revisi
3、on to the rst edition of the Standard for Safety for Special Purpose Aboveground Tanks for Specic Flammable or Combustible Liquids, UL 142A, is being issued to correct the publication date on the title page. This is an editorial correction, no requirements have changed The new requirements are subst
4、antially in accordance with Proposal(s) on this subject dated October 6, 2017 and March 16, 2018. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise wi
5、thout prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirec
6、t or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liability for any d
7、amage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attor
8、neys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. MAY 25, 2018 UL 142A tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL MAY 25, 2018 UL 142A tr2
9、 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL MAY 25, 2018 1 UL 142A Standard for Special Purpose Aboveground Tanks for Specic Flammable or Combustible Liquids First Edition May 25, 2018 This ANSI/UL Standard for Safet
10、y consists of the First Edition. The most recent designation of ANSI/UL 142A as an American National Standard (ANSI) occurred on May 24, 2018. ANSI approval for a standard does not include the Cover Page, Transmittal Pages, and Title Page. Comments or proposals for revisions on any part of the Stand
11、ard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at https:/. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way.
12、All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. COPYRIGHT 2018 UNDERWRITERS LABORATORIES INC. ANSI/UL 142a-2018UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISS
13、ION FROM UL MAY 25, 2018 UL 142A 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS INTRODUCTION 1 Scope .4 2 General 6 2.1 Units of measurement.6 2.2 Undated references .6 3 Glossary .6 CONSTRUCTION 4 General Con
14、struction for All Special Purpose Tanks.9 4.1 Containment type, shape, orientation, dimensions and capacity 9 4.2 Materials and joints .9 4.3 Openings and connections .10 4.4 Interstitial spaces 10 4.5 Manways .10 4.6 Painting 11 5 Specic Construction of Special Purpose Tanks .11 5.1 Generator base
15、tanks 11 5.2 Work top tanks 12 5.3 Lube oil tanks .13 5.4 Used oil tanks.14 5.5 Day tanks 15 5.6 Supports, accessories and components 16 PERFORMANCE 6 General Performance for All Special Purpose Tanks .17 6.1 General 17 6.2 Loading and lifting tests 17 6.3 Leakage and strength tests .19 MANUFACTURER
16、 AND PRODUCTION TESTS 7 Production Leakage Tests 20 MARKINGS 8 General Markings, and Methods for All Special Purpose Tanks20 9 General Markings for All Special Purpose Tanks.21 10 Special Markings for Each Special Purpose Tank Type22 MAY 25, 2018 UL 142A 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR F
17、URTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL INTRODUCTION 1 Scope 1.1 These requirements cover special purpose steel aboveground tanks for specic fuels or liquids and/or use applications as indicated for each special purpose tank type, which are intends to address the specic design
18、s, features, limitations, use factors and other unique characteristics of each type. These requirements are not covered by UL 142 for general purpose steel aboveground tanks for ammable and combustible liquids, as each special purpose tank deviates from them by construction, performance and/or marki
19、ngs for the intended use. The basic types of different special purpose tanks covered by this Standard are: a) Generator base tanks are designed for combined combustible fuel storage and structural support for diesel or turbine engine power generators, and are intended to be installed in accordance w
20、ith the Installation and Use of Stationary Combustion Engines and Gas Turbines, NFPA 37, or Emergency and Standby Power Systems, NFPA 110. Generator base tanks are limited to Combustible Class II or III fuels, such as diesel, kerosene, turbine oils or heavy oils. Covered options may include re resis
21、tance, damage resistance and/or tank support evaluations. b) Work top tanks are designed for combined combustible liquid storage and structural working surface, and are intended to be installed in accordance with NFPA 30, Code for Flammable and Combustible Liquids, NFPA 30A, Code for Motor Fuel Disp
22、ensing Facilities and Repair Garages, or NFPA 31, Installation of Oil-Burning Equipment. Work top tanks are limited to Combustible Class III liquids, such as heavy fuel oils, new/used lube oils, hydraulic/transmission oils, or similar working uids. Covered options may include racks, shelves and/or t
23、ank support evaluations. c) Lube oil tanks are designed for storage of unused lubricating oils and similar combustible liquids, and are intended to be installed in accordance with NFPA 30, Code for Flammable and Combustible Liquids, NFPA 30A, Code for Motor Fuel Dispensing Facilities and Repair Gara
24、ges, or NFPA 31, Installation of Oil-Burning Equipment. Lube oil tanks are limited to Combustible Class IIIB oils, such as motor crankcase oils, hydraulic/transmission oils, machine/ cutting oils, or similar uids. Covered options may include dispensing equipment and/or tank support evaluations. d) U
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL142A2018ULSTANDARDFORSAFETYSPECIALPURPOSEABOVEGROUNDTANKSFORSPECIFICFLAMMABLEORCOMBUSTIBLELIQUIDSFIRSTEDITIONPDF

链接地址:http://www.mydoc123.com/p-1067472.html