SSPC PAINT 41-2008 Moisture-Cured Polyurethane Primer or Intermediate Coat Micaceous Iron Oxide Reinforced Performance-Based《基于性能的强化云母氧化铁水固聚氨酯底漆或中间漆》.pdf
《SSPC PAINT 41-2008 Moisture-Cured Polyurethane Primer or Intermediate Coat Micaceous Iron Oxide Reinforced Performance-Based《基于性能的强化云母氧化铁水固聚氨酯底漆或中间漆》.pdf》由会员分享,可在线阅读,更多相关《SSPC PAINT 41-2008 Moisture-Cured Polyurethane Primer or Intermediate Coat Micaceous Iron Oxide Reinforced Performance-Based《基于性能的强化云母氧化铁水固聚氨酯底漆或中间漆》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、SSPC-Paint 41February 1, 20081SSPC: The Society for Protective CoatingsPainT SPECiFiCaTiOn nO. 41Moisture-Cured Polyurethane Primer or intermediate Coat, Micaceous iron Oxide Reinforced, Performance-Based1. ScopeThis specification contains performance requirements for a moisture-cured aromatic polyu
2、rethane coating with a thermoset binder and micaceous iron oxide pigment reinforcement.2. Description2.1 This coating is a single-package moisture-cured polyurethane coating characterized by the presence of free isocyanate groups capable of reacting with atmospheric mois-ture in order to form a soli
3、d film.2.2 Coatings meeting the requirements of this specifica-tion are generally suitable for exposures in environmental zones 1A (interior, normally dry), 1B (exterior, normally dry), 2A (frequently wet by fresh water excluding immersion), 2B (frequently wet by salt water, excluding immersion), 3B
4、 (chemical exposure, neutral) and 3C (chemical exposure, alkaline). Primer/intermediate coat systems described in this standard meet the performance requirements of Section 7.4 of SSPC-Paint 40 (including Environmental Zone 2C-Fresh Water Immersion).2.3 This coating is intended for spray application
5、 according to manufacturers instructions, with allowance for small area touch-up by brush (see Note 11.1) either directly to a steel substrate, or over itself or a compatible primer such as SSPC-Paint 40 or other primers recommended by the coating manufacturer. 3. Referenced Standards3.1 The latest
6、issue, revision, or amendment of the refer-enced documents in effect on the date of invitation to bid shall govern unless otherwise specified. Those documents marked with an asterisk (*) are referenced only in the Notes or the Appendix, which are not requirements of this specification.3.2. If there
7、is a conflict between the requirements of any of the cited reference documents and this specification, the requirements of this specification shall prevail.3.3 SSPC STanDaRDS anD JOinT STanDaRDS: Guide 13 Guide for the Identification and Use of Industrial Coating Materials in Computerized Product Da
8、ta-bases PA 2 Measurement of Dry Coating Thick-ness with Magnetic GagesPaint 40 Zinc-Rich Moisture Cure Poly-urethane Primer, Performance BasedSP 1 Solvent CleaningSP 5/NACE No. 1 White Metal Blast Cleaning3.4 aSTM inTERnaTiOnaL STanDaRDS:1D 185 Standard Test Methods for Coarse Particles in Pigments
9、* D 562 Standard Test Method for Consistency of Paints Measuring Krebs Unit (KU) Viscosity Using a Stormer-Type ViscometerD 714 Standard Test Method for Evaluating Degree of Blistering of Paints* D 1475 Standard Test Method for Density of Liquid Coatings, Inks, and Related ProductsD 1640 Standard Te
10、st Methods for Drying, Curing, or Film Formation of Organic Coatings at Room TemperatureD 1654 Standard Test Method for Evaluation of Painted or Coated Specimens Subjected to Corrosive Environments* D 2369 Standard Test Method for Volatile Content of Coatings* D 2371 Standard Test Method for Pigment
11、 Content of Solvent-Reducible PaintsD 2794 Standard Test Method for Resistance of Organic Coatings to the Effects of Rapid Deformation (Impact)D 4417 Standard Test Methods for Field Measurement of Surface Profile of Blast Cleaned SteelD 4541 Standard Test Method for Pull-Off Strength of Coatings Usi
12、ng Portable Adhesion Testers1 ASTM International, 100 Barr Harbor Drive, West Conshohock-en, PA 19428-2959. Standards available online from http:/www.astm.org.SSPC-Paint 41February 1, 20082D 5894 Standard Practice for Cyclic Salt Fog/UV Exposure of Painted Metal, (Alternating Exposures in a Fog/Dry
13、Cabinet and a UV/Condensation Cabinet)3.5 aMERiCan naTiOnaL STanDaRDS inSTiTUTE (anSi) STanDaRD:2ANSI Z129.1 Hazardous Industrial ChemicalsPrecautionary Labeling4. Composition Requirements4.1 The manufacturer is given wide latitude in the selection of materials and manufacturing processes. 4.2 Pigme
14、nt Requirement4.2.1 Micaceous iron oxide is a required pigment compo-nent in this coating (see Note 11.2 for typical formulation percentage ranges). The manufacturer shall provide informa-tion on the micaceous iron oxide content on the product data sheet, or as required by the purchaser.4.2.2 Option
15、al pigment components include extenders, tinting colors and suspension control agents.4.3 Resin Requirement: The resin used in the coating shall be a polyisocyanate-based product that cures through a chemical reaction with atmospheric moisture. Use of other resins or modifiers shall be limited to pr
16、oducts necessary for formula ingredient compatibility and to improve recoating properties. See Note 11.3 for information on VOC content, and Note 11.4 for information on modifying resins.4.4 analytical Test Data: If mutually agreed upon by purchaser and supplier, the coating manufacturer shall provi
17、de certificates of analysis for coating batches qualified by inde-pendent testing to meet this standard, including petrographic analysis of the percentage of lamellar particles present in the micaceous iron oxide pigment.5. Standard Testing Conditions 5.1 TEST PanELS: The hot rolled steel test panel
18、s shall conform to ASTM A 572. Panel size shall be 100 mm x 150 mm x 3.2 mm (4 inch x 6 inch x 1/8 inch). Test panels shall be solvent cleaned in accordance with SSPC-SP 1 prior to blast cleaning. The test panels shall be blast cleaned in accordance with SSPC-SP 5. The blast profile shall be 44 to 5
19、7 micrometers (1.75 to 2.25 mils) as measured in accordance with ASTM D 4417, Method C.2American National Standards Institute, 1819 L Street, NW, Suite 600, Washington, DC 20036. Standards available online from www.ansi.org.5.2 aPPLiCaTiOn: The coating shall be spray applied as a single coat in acco
20、rdance with recommendations on the manufacturers product data sheet. The coating shall show no streaking, running, sagging, or other defects during application or while drying.5.3 DRY FiLM THiCKnESS: The dry film thickness (DFT) on the test panels shall meet the manufacturers written recom-mended ra
21、nge. The DFT shall be measured in accordance with SSPC-PA 2, Appendix 5. 5.4 CURE: The primer shall be dried and cured in accor-dance with manufacturers written recommendations. Before any testing, all coated panels shall be aged for a minimum of 7 days in an environment with a minimum relative humi
22、dity of 50%, and at a temperature of 23 2 C (73.5 3.5 F), as described in paragraph 5.1 of ASTM D 1640.5.5 SCRiBinG: Scribe two parallel lines on the face of the coated panels so as to expose the underlying metal before testing. The lines shall be at least 2.5 cm (1 inch) from the edge, the top, and
23、 the bottom of each panel and at least 5 cm (2 inches) from each other. Each scribe shall be 6 cm (2.4 inches) long. The scribes may run vertically or at an angle across the face of the panel. Follow the scribe-making procedure described in ASTM D 1654.5.6 BaCKS anD EDGES: Coat and seal all edges an
24、d the back side of each panel with a coating or tape that will provide the necessary protection to these surfaces.6. Requirements of Liquid Coating6.1 MiXinG: The coating shall be mixed and dispersed to produce a product that is uniform, stable, free from grit, and in conformance with the requiremen
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SSPCPAINT412008MOISTURECUREDPOLYURETHANEPRIMERORINTERMEDIATECOATMICACEOUSIRONOXIDEREINFORCEDPERFORMANCEBASED

链接地址:http://www.mydoc123.com/p-1054477.html