SAE J 2782-2010 Performance Specifications for a Midsize Male Pedestrian Research Dummy《中型男性行人研究仿制品用性能规范》.pdf
《SAE J 2782-2010 Performance Specifications for a Midsize Male Pedestrian Research Dummy《中型男性行人研究仿制品用性能规范》.pdf》由会员分享,可在线阅读,更多相关《SAE J 2782-2010 Performance Specifications for a Midsize Male Pedestrian Research Dummy《中型男性行人研究仿制品用性能规范》.pdf(58页珍藏版)》请在麦多课文档分享上搜索。
1、_ SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising there
2、from, is the sole responsibility of the user.” SAE reviews each technical report at least every five years at which time it may be reaffirmed, revised, or cancelled. SAE invites your written comments and suggestions. Copyright 2010 SAE International All rights reserved. No part of this publication m
3、ay be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: +1 724-776-4970 (outside U
4、SA) Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.orgSAE values your input. To provide feedbackon this Technical Report, please visit http:/www.sae.org/technical/standards/j2782_201010SURFACEVEHICLEINFORMATIONREPORTJ2782 OCT2010 Issued 2010-10 Performance Specificati
5、ons for a Midsize Male Pedestrian Research Dummy RATIONALE Not applicable. FOREWORD Worldwide, vehicle impacts with pedestrians constitute the most frequent cause of traffic-related fatalities. As a result, knowledge about pedestrian crashes is essential to the reduction of fatalities and injuries f
6、or these “vulnerable road users“ (see definitions). Currently available tools and methods for studying pedestrian casualties include statistical databases, component testing, and computer simulations. While currently in limited use, full-scale vehicle tests with a pedestrian crash-test dummy are an
7、essential component for understanding the motions and sequence of body component impacts which lead to pedestrian trauma and for developing appropriate countermeasures. Possible uses for such a dummy could include the: Study of pedestrian kinematics Facilitation of crash reconstruction techniques in
8、cluding pedestrian kinematics Assessment of injury risk probabilities for given vehicle, crash, and countermeasure combinations Design of pedestrian protection systems Evaluation of active systems (pop-up hoods, airbags, etc.) Refinement of component test parameters and procedures Validation of comp
9、uter simulations NOTE: This SAE document is intended as a guide toward standard practice and is subject to change to keep pace with experience and technical advances. SAE J2782 Issued OCT2010 Page 2 of 58TABLE OF CONTENTS 1. SCOPE 51.1 Purpose . 52. REFERENCES 52.1 Applicable Documents 52.1.1 SAE an
10、d Stapp Publications . 52.1.2 Government Publications 62.1.3 ESV Publications . 72.1.4 ICRASH Publication 72.1.5 IRCOBI Publications . 72.1.6 ISO Publications 82.1.7 ISB Publications 82.1.8 UMTRI Publication 82.1.9 USACM Publication . 82.1.10 Other Publications . 82.2 Related Publications . 92.2.1 S
11、AE and Stapp Publications . 92.2.2 Government Publications 102.2.3 ESV Publications . 102.2.4 IRCOBI Publications . 112.2.5 ISO Publications 112.2.6 SAFE Publication 112.2.7 Other Publications . 112.3 Definitions . 122.4 Symbols, Subscripts and Abbreviations 122.4.1 Abbreviations 122.4.2 Symbols 133
12、. REQUIREMENTS . 133.1 Head 133.1.1 Geometric and Mass Characteristics 133.1.2 Head Biofidelity . 133.1.3 Repeatability and Reproducibility 163.2 Neck 163.2.1 MASS CHARACTERISTICS . 163.2.2 Neck Biofidelity 163.2.3 Repeatability and Reproducibility 163.3 Shoulder 163.3.1 Geometric Properties 163.3.2
13、 Shoulder Biofidelity . 173.3.3 Repeatability and Reproducibility 173.4 Thorax . 183.4.1 Geometric and Mass Characteristics 183.4.2 Thorax Biofidelity . 203.4.3 Repeatability and Reproducibility 213.5 Upper Extremities 213.5.1 Location of Center of Gravity 213.5.2 Mass 223.6 Abdomen and Pelvis . 223
14、.6.1 Geometric and Mass Characteristics 223.6.2 Pelvis Biofidelity 233.6.3 Repeatability and Reproducibility 243.7 Thigh . 243.7.1 Geometric Properties 243.7.2 Mass 253.7.3 Location of Center of Gravity 25SAE J2782 Issued OCT2010 Page 3 of 583.8 Knees 253.8.1 Geometric Properties 253.8.2 Knee Biofid
15、elity . 253.8.3 Repeatability and Reproducibility 253.9 Legs . 273.9.1 Geometric Properties 273.9.2 Mass 273.9.3 Location of Center of Gravity 273.9.4 Leg Biofidelity 273.9.5 Repeatability and Reproducibility 273.10 Ankles and Feet 293.10.1 Shoes 293.10.2 Mass 293.10.3 Location of Center of Gravity
16、293.11 Clothing . 293.12 Whole Body . 293.12.1 Body Structures . 293.12.2 Geometric and Mass Characteristics 303.12.3 Instrumentation Compatibility 303.12.4 Biofidelity . 313.12.5 Handling 313.12.6 Repeatability and Reproducibility 313.12.7 Durability . 313.13 Sensors and Data Acquisition Systems (D
17、AS) . 323.13.1 Sensor Locations 323.13.2 Sensor and DAS Specifications 323.13.3 Data Acquisition 324. TEST METHODS AND ANALYSIS PROCEDURES 334.1 Head Biofidelity . 334.1.1 Frontal Drop Test 334.1.2 Lateral Drop Test 334.2 Neck 334.2.1 Neck Flexion Test . 334.2.2 Lateral Pendulum Test 334.3 Shoulder
18、334.4 Thorax . 334.4.1 Frontal Pendulum Test 334.4.2 Lateral Pendulum Test 334.5 Pelvis . 334.5.1 Lateral Pendulum Test (6 m/s) 334.5.2 Lateral Pendulum Test (10 m/s) 344.6 Knee 344.7 Legs . 354.8 Whole Body . 364.8.1 Buck Specifications . 364.8.2 Impact Speed 374.8.3 Dummy Pre-Test Position . 374.8
19、.4 High Speed Cameras and Analysis Procedures . 385. NOTES 435.1 Marginal Indicia . 43APPENDIX A RATIONALE REGARDING BACKGROUND AND REQUIREMENTS FOR A STANDARDIZED PEDESTRIAN RESEARCH DUMMY . 44SAE J2782 Issued OCT2010 Page 4 of 58FIGURE 1 HEAD HEIGHT . 14FIGURE 2 HEAD BREADTH . 14FIGURE 3 HEAD CIRC
20、UMFERENCE . 15FIGURE 4 HEAD LENGTH 15FIGURE 5 SHOULDER BREADTH . 17FIGURE 6 FORCE VERSUS TIME LATERAL SHOULDER CORRIDOR 18FIGURE 7 THORAX CIRCUMFERENCE 19FIGURE 8 THORAX INTERSCYE DISTANCE . 19FIGURE 9 4.27 M/S FRONTAL PENDULUM FORCE-DEFLECTION RESPONSE CORRIDOR 20FIGURE 10 ISO/TR 9790:1999(E) FORCE
21、 VERSUS TIME LATERAL THORAX CORRIDOR . 21FIGURE 11 HIP CIRCUMFERENCE . 22FIGURE 12 BI-TROCHANTERIC BREADTH 23FIGURE 13 FORCE VERSUS VELOCITY LATERAL PELVIS CORRIDOR . 24FIGURE 14 THIGH CIRCUMFERENCE 25FIGURE 15 KNEE CIRCUMFERENCE . 26FIGURE 16 LINEAR BOUNDARIES OF KNEE LATERO-MEDIAL RESPONSE CORRIDO
22、R . 26FIGURE 17 MAXIMUM LEG CIRCUMFERENCE . 28FIGURE 18 LINEAR BOUNDARIES OF LEG LATERAL BENDING RESPONSE CORRIDOR . 28FIGURE 19 KNEE EXAMPLE TEST SET-UP . 34FIGURE 20 SCHEMATIC FOR KNEE JOINT KINETICS 35FIGURE 21 LEG EXAMPLE TEST SET-UP 36FIGURE 22 SCHEMATIC OF THE POSITIONING MEASURES 39TABLE 1 LA
23、TERAL SHOULDER PENDULUM FORCE - TIME CORRIDOR . 18TABLE 2 4.27 M/S FRONTAL PENDULUM FORCE-DEFLECTION RESPONSE CORRIDOR 20TABLE 3 ISO/TR 9790:1999(E) FORCE VERSUS TIME LATERAL THORAX CORRIDOR . 21TABLE 4 LATERAL PELVIS PENDULUM FORCE - VELOCITY CORRIDOR . 24TABLE 5 KNEE STIFFNESS CORRIDOR 27TABLE 6 L
24、EG STIFFNESS CORRIDOR . 29TABLE 7 DUMMY WHOLE BODY DIMENSIONS (ALL DIMENSIONS ARE WITH SHOES) 30TABLE 8 DUMMY SENSOR MEASURES(5) 32TABLE 9 POSITIONING MEASURES . 38SAE J2782 Issued OCT2010 Page 5 of 581. SCOPE While it is recognized that collisions involve pedestrians of all sizes, this Information
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEJ27822010PERFORMANCESPECIFICATIONSFORAMIDSIZEMALEPEDESTRIANRESEARCHDUMMY 中型 男性 行人 研究 仿制品 性能 规范 PDF

链接地址:http://www.mydoc123.com/p-1027585.html