SAE J 910-1988 Hazard Warning Signal Switch Standard《危险警告信号开关》.pdf
《SAE J 910-1988 Hazard Warning Signal Switch Standard《危险警告信号开关》.pdf》由会员分享,可在线阅读,更多相关《SAE J 910-1988 Hazard Warning Signal Switch Standard《危险警告信号开关》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、SAE-J910ADOPTION NOTICESAE-J910, “SWITCH, HAZARD WARNING SIGNAL“, was adopted on04-APR-90 for use by the Department of Defense (DoD). Proposedchanges by DoD activities must be submitted to the DoD AdoptingActivity: Commander, Defense Supply Center Philadelphia, ATTN:DSCP-ITAA, 700 Robbins Avenue, Ph
2、iladelphia, PA 19111-5096. Copies of this document may be purchased from the Society ofAutomotive Engineers 400 Commonwealth Drive Warrendale,Pennsylvania, United States, 15096-0001. http:/www.sae.org/_Custodians: Adopting Activity:DLA - ISArmy - ATDLA - ISFSC 6220DISTRIBUTION STATEMENT A: Approved
3、for public release; distributionis unlimited.SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirelyvoluntary, and its applicability and suitability for any particular use, inclu
4、ding any patent infringement arising therefrom, is the sole responsibility of the user.”SAE reviews each technical report at least every five years at which time it may be reaffirmed, revised, or cancelled. SAE invites your written comments and suggestions.QUESTIONS REGARDING THIS DOCUMENT: (412) 77
5、2-8512 FAX: (412) 776-0243TO PLACE A DOCUMENT ORDER; (412) 776-4970 FAX: (412) 776-0790http:www.sae.orgCopyright 1988 Society of Automotive Engineers, Inc.All rights reserved. Printed in U.S.A.SURFACEVEHICLE400 Commonwealth Drive, Warrendale, PA 15096-0001STANDARDAn American National StandardJ910REV
6、.OCT88Issued 1965-01Revised 1988-10Superseding J910 OCT77(R) HAZARD WARNING SIGNAL SWITCHForewordThis Document has not changed other than to put it into the new SAE Technical Standards BoardFormat.1. ScopeThis standard defines the test conditions, procedures and performance specifications for 6, 12
7、and24-V manually actuated hazard warning signal switch.2. References2.1 Applicable PublicationThe following publication forms a part of the specification to the extent specifiedherein. Unless otherwise indicated the lastest revision of SAE publications shall apply.2.1.1 SAE PUBLICATIONAvailable from
8、 SAE, 400 Commonwealth Drive, Warrendale, PA 15096-0001.SAE J589bTurn Signal Switch3. Definitions3.1 Hazard Warning SwitchAn operator actuated device whose function is to cause at least one turn signallamp on the left and right of the front, and left and right of the rear of the vehicle to flash sim
9、ultaneously toindicate to the approaching driver the presence of a vehicular hazard.3.2 Combination Turn Signal and Hazard Warning Signal3.2.1 A combination switch is defined as a hazard warning switch combined in the same housing as the turn signalswitch.3.2.2 The operating motion of the hazard war
10、ning signal switch function shall differ from the actuating motion ofthe turn signal function.SAE J910 Revised OCT88-2-4. Test Requirements4.1 Test Equipment and Instrumentation4.1.1 POWER SUPPLYThe power supply shall not generate any adverse transients not present in motor vehicles,and shall comply
11、 with the following specifications:a. Output CurrentThe power supply shall be capable of supplying the continuous current of the designelectrical load and the in-rush current, as required by the bulb load complement.b. Output Regulation:DynamicThe dynamic output voltage at the supply shall not devia
12、te more than 1.0 V from zero tomaximum load (including in-rush current) and shall recover 63% of its maximum excursion within100milliseconds.StaticThe static output voltage at the supply shall not deviate more than 2% with changes in staticload from zero to maximum (not including in-rush current), a
13、nd means shall be provided tocompensate for static input line voltage variations.c. Ripple VoltageThe ripple output voltage shall be a maximum of 300 mV peak-to-peak.4.1.2 VOLTMETERA voltmeter with a 0-30 V maximum full scale deflection and 1/2% accuracy should be used. NOTEA digital meter having at
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEJ9101988HAZARDWARNINGSIGNALSWITCHSTANDARD 危险 警告 信号 开关 PDF

链接地址:http://www.mydoc123.com/p-1027304.html