《SAE J 1660-2011 Fittings and Labels for Retrofit of CFC-12 (R-12) Mobile Air-Conditioning Systems to HFC-134a (R-134a)《改造为HFC-134a (R-134a)的CFC-12 (R-12)移动空调系统的配件和标签》.pdf》由会员分享,可在线阅读,更多相关《SAE J 1660-2011 Fittings and Labels for Retrofit of CFC-12 (R-12) Mobile Air-Conditioning Systems to HFC-134a (R-134a)《改造为HFC-134a (R-134a)的CFC-12 (R-12)移动空调系统的配件和标签》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、_ SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising there
2、from, is the sole responsibility of the user.” SAE reviews each technical report at least every five years at which time it may be reaffirmed, revised, or cancelled. SAE invites your written comments and suggestions. Copyright 2011 SAE International All rights reserved. No part of this publication m
3、ay be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: +1 724-776-4970 (outside U
4、SA) Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.orgSAE values your input. To provide feedbackon this Technical Report, please visit http:/www.sae.org/technical/standards/J1660_201104SURFACEVEHICLERECOMMENDEDPRACTICEJ1660 APR2011 Issued 1993-06 Stabilized 2011-04 Su
5、perseding J1660 NOV1998 Fittings and Labels for Retrofit of CFC-12 (R-12) Mobile Air-Conditioning Systems to HFC-134a (R-134a) RATIONALE The technical report covers technology, products, or processes which are mature and not likely to change in the foreseeable future. STABILIZED NOTICE This document
6、 has been declared “Stabilized“ by the SAE Interior Climate Control Committee and will no longer be subjected to periodic reviews for currency. Users are responsible for verifying references and continued suitability of technical requirements. Newer technology may exist. Copyright SAE International
7、Provided by IHS under license with SAENot for ResaleNo reproduction or networking permitted without license from IHS-,-,-SAE J1660 Stabilized APR2011 Page 2 of 4 1. ScopeThis SAE Recommended Practice describes the specific measures required to meet SAEestablished criteria when retrofitting CFC-12 (R
8、-12) mobile air-conditioning (A/C) systems to HFC-134a (R-134a), with regards to fittings and labeling. This document is complete only when combined with therequirements of SAE J1657.2. References2.1 Applicable PublicationsThe following publications form a part of the specification to the extent spe
9、cifiedherein. Unless otherwise indicated, the latest revision of SAE publications shall apply.2.1.1 SAE PUBLICATIONSAvailable from SAE, 400 Commonwealth Drive, Warrendale, PA 15096-0001.SAE J639Safety and Containment of Refrigerant for Vapor Compression Systems for Mobile Air-Conditioning SystemsSAE
10、 J1627Rating Criteria for Electronic Refrigerant Leak DetectorsSAE J1628 Technician Procedure for Using Electronic Refrigerant Leak Detector for Service of MobileAir-Conditioning SystemsSAE J1657Selection Criteria for Retrofit Refrigerants to Replace CFC-12 (R-12) in Mobile Air-Conditioning SystemsS
11、AE J1661Procedure for Retrofitting CFC-12 (R-12) Mobile Air-Conditioning Systems to HFC-134a(R-134a)SAE J2064HFC-134a (R-134a) Refrigerant Automotive Air-Conditioning Hose2.1.2 UL PUBLICATIONAvailable from Underwriters Laboratories, Inc., 333 Pfingsten Road, Northbrook, IL60062-2096.ANSI/UL 969-1991
12、Marking and Labeling Systems3. Fittings3.1 There shall be at least one system service port which complies with SAE J639 for HFC-134a (R-134a). If botha high side and low side service port exist, there shall be at least one high side and at least one low sidesystem service port which complies with SA
13、E J639 for HFC-134a (R-134a) after the retrofit is completed.Copyright SAE International Provided by IHS under license with SAENot for ResaleNo reproduction or networking permitted without license from IHS-,-,-SAE J1660 Stabilized APR2011 Page 3 of 4 3.2 When existing CFC-12 (R-12) service ports are
14、 to be retrofit, HFC-134a (R-134a) conversion assemblies shallbe fitted. The conversion assembly shall attach to the CFC-12 (R-12) fitting with a thread lock adhesive and/ora separate mechanical latching mechanism (e.g., snap-ring, drive-wire, roll pin, etc.) in a manner that preventsthe assembly fr
15、om being removed inadvertently.3.2.1 A conversion assembly that consists of flexible portion(s) as well as nonflexible couplings and/or fittings shallcomply with SAE J639. Such a conversion assembly, up to and including the appropriate CFC-12 (R-12)interface, shall be considered a hose assembly and
16、shall meet all requirements of SAE J2064. Such aconversion assembly shall also meet the following vibration test requirements. Following successfulcompletion of the SAE J2064 Coupling Integrity Test, subject these same test specimen assemblies, stillcharged with the appropriate amount of refrigerant
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEJ16602011FITTINGSANDLABELSFORRETROFITOFCFC12R12MOBILEAIRCONDITIONINGSYSTEMSTOHFC134AR134A 改造 HFC134AR134A

链接地址:http://www.mydoc123.com/p-1026447.html