SAE AS 50861A-2011 Wire Electric Polyvinyl Chloride Insulated Copper or Copper Alloy《聚氯乙烯包裹铜和铜合金电线》.pdf
《SAE AS 50861A-2011 Wire Electric Polyvinyl Chloride Insulated Copper or Copper Alloy《聚氯乙烯包裹铜和铜合金电线》.pdf》由会员分享,可在线阅读,更多相关《SAE AS 50861A-2011 Wire Electric Polyvinyl Chloride Insulated Copper or Copper Alloy《聚氯乙烯包裹铜和铜合金电线》.pdf(27页珍藏版)》请在麦多课文档分享上搜索。
1、_SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising theref
2、rom, is the sole responsibility of the user.” SAE reviews each technical report at least every five years at which time it may be reaffirmed, revised, or cancelled. SAE invites your written comments and suggestions. Copyright 2011 SAE International All rights reserved. No part of this publication ma
3、y be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: +1 724-776-4970 (outside US
4、A) Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.orgSAE values your input. To provide feedback on this Technical Report, please visit http:/www.sae.org/technical/standards/AS50861AAEROSPACESTANDARDAS50861 REV. A Issued 1998-03 Reaffirmed 2004-06 Revised 2011-01Supers
5、eding AS50861 Wire, Electric, Polyvinyl Chloride Insulated, Copper or Copper Alloy FSC 6145 RATIONALELimit Scope ballot required to incorporate AS50561-A3, update references, and remove government references. 1. SCOPE 1.1 Scope This specification covers polyvinyl chloride insulated single conductor
6、electric wires made with tincoated copper conductors or silver-coated copper alloy conductors as specified in the applicable detail specification. The polyvinyl chloride insulation of these wires may be used alone or in combination with other insulating or protective materials. 1.2 Classification Th
7、e wires shall be as described in the applicable detail specification. 1.2.1 Part numbers: Part numbers under this specification are coded as in the following example: M5086/1 - 22 - 9Applicable specifcation Wire size Insulation color sheet designator or designators 1.2.2 Temperature rating of finish
8、ed wire: The maximum conductor temperature of the finished wire for continuous use shall be as specified in the applicable detail specification (6.1.1). SAE AS50861A Page 2 of 272. APPLICABLE DOCUMENTS The following publications form a part of this document to the extent specified herein. Unless oth
9、erwise specified the applicable issue of the other publications shall be the issue in effect on the date of the purchase order. In the event of conflict between the text of this document and references cited herein, the text of this document takes precedence. Nothing in this document, however, super
10、sedes applicable laws and regulations unless a specific exemption has been obtained.2.1 SAE Publications Available from SAE International, 400 Commonwealth Drive, Warrendale, PA 15096-0001, Tel: 877-606-7323 (inside USA and Canada) or 724-776-4970 (outside USA), www.sae.org.AS5086/1* Wire, Electric,
11、 Polyvinyl Chloride Insulated, Nylon Jacket, Tin-Coated Copper Conductor, 600-Volt, 105 C AS5086/2* Wire, Electric, Polyvinyl Chloride Insulated, PVC - Glass - Nylon, Tin-Coated Copper Conductor, 600-Volt, 105 C AS5086/3* Wire, Electric, Polyvinyl Chloride Insulated, PVC - Glass - PVC - Nylon, Tin-C
12、oated Copper Conductor, 600-Volt, 105 C AS5086/48 Wire, Electric, Polyvinyl Chloride Insulated, Nylon Jacket, Tin-Coated Copper Conductor, 3000-Volt, 105 C AS5086/5* Wire, Electric, Polyvinyl Chloride Insulated, Polyvinylidene Fluoride Jacket, Tin-Coated Copper Conductor, 600-Volt, 110 C AS5086/6 Wi
13、re, Electric, Polyvinyl Chloride Insulated, Polyvinylidene Fluoride Jacket, Silver-Coated Copper Alloy Conductor, 600-Volt, 110 C AS5086/7* Wire, Electric, Polyvinyl Chloride Insulated, Nylon Jacket, Tin-Coated Copper Conductor, Medium Weight, 600-Volt, 105 C AS5086/8* Canceled, 14 November 1974 (Wi
14、re, Electric, Polyvinyl Chloride Insulated, Polyvinylidene Fluoride Jacket, Tin-Coated Copper Conductor, Light Weight, 600-Volt, 110 C) *SAE AS58091 Detail Specifications 2.2 U.S. Government Publications Available from the Document Automation and Production Service (DAPS), Building 4/D, 700 Robbins
15、Avenue, Philadelphia, PA 19111-5094, Tel: 215-697-6257, http:/assist.daps.dla.mil/quicksearch/.SD-6 Provisions Governing Qualification H4/H8 Catalog of Commercial and Government Entities (CAGE) (Battle Creek Customer Contact Center, Defense Logistics Information Service, 74 Washington Avenue N., Bat
16、tle Creek, MI 49017-3084) MIL-STD-104 Limits for Electrical Insulation Color MIL-STD-129 Military Marking for Shipment and Storage FED-STD-228 Cable and Wire, Insulated; Methods of Testing UU-T-450 Tissue, Facial SAE AS50861A Page 3 of 27MIL-C-572 Cords, Yarns and Monofilaments, Organic Synthetic Fi
17、ber MIL-STD-681 Identification Coding and Application of Hookup and Lead Wire TT-I-735 Isopropyl Alcohol MIL-Y-1140 Yarn, Cord, Sleeving, Cloth, and Tape, Glass MIL-PRF-5606 Hydraulic Fluid, Petroleum Base, Aircraft, Missile, and Ordnance MIL-DTL-5624 Turbine Fuel, Aviation, Grades JP-4 and JP-5 MIL
18、-DTL-12000 Cable, Cord, and Wire, Electric, Packaging of MIL-PRF-23699 Lubricating Oil, Aircraft Turbine Engine, Synthetic Base MIL-STD-29606 Wire, Electrical, Stranded, Uninsulated Copper, Copper Alloy, or Aluminum, or Thermocouple Extension, General Specification For MIL-DTL-83133 Turbine Fuel, Av
19、iation, Kerosene Types, NATO F-34 (JP-8) and NATO F-35 2.3 Other Publications 2.3.1 ASQ Publications Available from American Society for Quality, 600 North Plankinton Avenue, Milwaukee, WI 53203, Tel: 800-248-1946 (United States or Canada) or +1-414-272-8575 (International), www.asq.org.ASQC Z1.4 Sa
20、mpling Procedures and Tables for Inspection by Attributes 2.3.2 ASTM Publications Available from ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959, Tel: 610-832-9585, www.astm.org.ANSI/ASTM B 3 Standard Specification for Soft or Annealed Copper Wire ANSI/ASTM
21、 B 33 Standard Specification for Tinned Soft or Annealed Copper Wire for Electrical Purposes ANSI/ASTM B 298- Standard Specification for Silver-Coated Soft or Annealed Copper Wire ANSI/ASTM D 1371 Recommended Practice for Cleaning Plastic Specimens for Insulation Resistance, Surface Resistance, and
22、Volume Resistivity Testing ANSI/ASTM D 3032 Standard Test Methods for Hookup Wire Insulation ASTM D 4066-94B Nylon, Injection and Extrusion Materials (PA) SAE AS50861A Page 4 of 273. REQUIREMENTS 3.1 Detail Specifications The requirements for the individual wires under this specification shall be as
23、 specified herein and in accordance with the applicable detail specification. In the event of discrepancy between this specification and the requirements of the applicable detail specification, the requirements of the detail specification shall govern, except that all detail specificationprovisions
24、concerning resistance to tape abrasion shall be considered as cancelled as of the issue date of Amendment 1 to this specification. 3.2 Classification of Requirements The applicable requirements are classified herein as follows: Requirement ParagraphQualification 3.3 Materials 3.4 Construction 3.5 Fi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEAS50861A2011WIREELECTRICPOLYVINYLCHLORIDEINSULATEDCOPPERORCOPPERALLOY 聚氯乙烯 包裹 铜合金 电线 PDF

链接地址:http://www.mydoc123.com/p-1024732.html