SAE AS 506-2004 High Temperature Insulated Terminals & Splices《高温绝缘终端和绞接件》.pdf
《SAE AS 506-2004 High Temperature Insulated Terminals & Splices《高温绝缘终端和绞接件》.pdf》由会员分享,可在线阅读,更多相关《SAE AS 506-2004 High Temperature Insulated Terminals & Splices《高温绝缘终端和绞接件》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、 AEROSPACE STANDARD High Temperature Insulated Terminals Types ET (250 volts), E (600 volts) and EE (1000 volts) STANDARDS MILITARY MIL-STD-202 Test Methods for Electronic and Electrical Component Parts OTHER PUBLICATIONS ISO/IEC Guide 22 General criteria for suppliers declaration of conformity ISO/
2、IEC 17025 General requirements for the competence of testing and calibration laboratories SAE AS506 - 3 - 3. REQUIREMENTS: 3.1 Design and Construction: 3.1.1 Wire Ranges: Terminal lugs and splices shall accommodate stranded wire sizes 26 through 4/0 AWG. 3.1.2 Wire Types: Terminal lugs and splices s
3、hall satisfactorily terminate NEMA Standards Publication No. HP 3-2000 (260 C wires only) nickel coated copper or copper alloy wire type E or EE and nickel coated copper or copper alloy wire in accordance with MIL-W-22759 (260 C wire only), MIL-W-25038 and MIL-DTL-81381. 3.1.3 Insulation Grip: Termi
4、nal lugs and splices in wire sizes 26-10 AWG shall be provided with insulation grips which shall support the intended wire. 3.1.4 Crimping Tools: Manufacturers recommended crimping tools as defined in Section 6, shall be used and may be either hand or power operated types having a positive close fea
5、ture. Crimping tools qualified to the requirements of the SAE specification MA5259 are recommended for termination devices in sizes 8 through 4/0 AWG. 3.1.5 Marking: Terminal lugs and splices and tools shall be marked or color coded in accordance with Table 2 to indicate the wire range for which the
6、y are intended. TABLE 2 Wire size in AWG Color 26-24 Black 22-20 Green 18-16 Orange 14 White 12-10 Black 8 Green 6 Orange 4 White 2 Black 0 Green 1/0 Orange 2/0 White 3/0 Black 4/0 Green SAE AS506 - 4 - 3.1.6 Materials: Materials shall be capable of withstanding temperatures of -55 to 260 C. The sur
7、face finish of current carrying parts shall be nickel plated. 3.2 Performance: 3.2.1 Examination of Product: The component shall be examined in accordance with 5.1.1 and meet the following requirements: a. The terminal and splice shall be in compliance with the manufacturer drawings before crimping.
8、 b. The terminal or splice shall have no cracks, splits, or damage to the insulation which might cause electrical failure after being crimped. c. The terminal or splice shall be in compliance with the manufacturer assembly instructions after crimping. 3.2.2 Heat Age: After being tested in accordance
9、 with 5.1.2, terminal lugs and splices shall meet the dielectric withstanding voltage requirements as specified in 3.2.10. Discoloration of the insulating material during this test shall not be cause for rejection. The plating shall show no evidence of cracking or splitting after testing when examin
10、ed under a 3X magnification. 3.2.3 Temperature Cycling: Terminal lugs and splices shall be subjected to 50 temperature cycles in accordance with 5.1.3. They shall show no evidence of cracking or splitting and shall meet the voltage drop requirements of 3.2.6 and the dielectric withstanding voltage r
11、equirements of 3.2.10. 3.2.4 Vibration: After being vibrated as specified in 5.1.4, terminal lugs and splices shall meet the voltage drop requirements of 3.2.6 and the tensile strength requirements of 3.2.11. 3.2.5 Salt Spray: After 48 hours of exposure to salt spray in accordance with 5.1.5, termin
12、al lugs and splices shall show no evidence of base metal exposure or blistering of the plated surfaces and meet the voltage drop requirements of 3.2.6 and the tensile strength requirements of 3.2.11. 3.2.6 Voltage Drop: The voltage drop when measured as specified in 5.1.6 shall not exceed the milliv
13、olt drop of an equivalent length of wire by more than the value specified in Table 3. 3.2.7 Low Temperature Crimp: After the low temperature crimp test described in 5.1.7 there shall be no evidence of cracking or splitting and the dielectric withstanding requirements of 3.2.10 shall be met. SAE AS50
14、6 - 5 - 3.2.8 Immersion: Terminal lugs and splices shall meet the dielectric withstanding voltage requirements after being immersed in fluids as specified in 5.1.8. When the terminal lug or splice materials are the same for all sizes, only one size needs to be tested. A particular fluid test is not
15、required if the material manufacturer certified compliance and the material is not modified by the component manufacturer. 3.2.9 Flammability: Insulation shall be self extinguishing within 3 seconds after being subjected to a flame as described in 5.1.9. 3.2.10 Dielectric Withstanding Voltage: The t
16、erminal lug and splice insulation shall withstand 1500 volts rms, 60 hertz, and 10 milliamp leakage current for a period of 1 minute when tested in accordance with 5.1.10. 3.2.11 Tensile Strength: The mechanical strength of crimped terminal lugs and splices shall not be less than the values listed i
17、n Table 3 when tested in accordance with 5.1.11 and terminated using the manufacturers tools as found in Section 6. 3.2.12 Axial Load: When tested as specified in 5.1.12 and terminated using the manufacturers tools as found in Section 6, the insulation and metal sleeve, if used, shall withstand the
18、minimum axial force specified in Table 3. The maximum allowable movement of the insulation and metal sleeve, if used, is 1/32 inch from its original position on the wire barrel. TABLE 3 - Voltage Drop and Tensile Strength Requirements Wire Size (AWG) Test Current (amperes) Maximum (1) Voltage Drop (
19、millivolt) Initial Maximum (1) Voltage Drop (millivolt) Final Minimum Tensile Strength (pounds) Minimum Axial Force (pounds) Before Crimping Minimum Axial Force (pounds) After Crimping 26 3 5 8 5 2 4 24 4.5 5 8 7 2 4 22 9 5 8 11 4 6 20 11 5 8 13 4 6 18 16 5 8 27 4 6 16 22 5 8 35 4 6 14 32 5 8 49 4 8
20、 12 41 5 8 77 4 8 10 55 5 8 105 4 8 8 73 6 101 4 135 2 181 1 211 0 245 00 283 000 328 0000 380 (1) Maximum Voltage Drop = Millivolt drop of equivalent length of wire plus values in table SAE AS506 - 6 - 4. QUALITY ASSURANCE PROVISIONS: 4.1 Qualification Tests: The manufacturer is responsible for the
21、 performance of all qualification testing requirements as specified herein. The manufacturer may use any facility meeting the requirements of ISO/IEC 17025 for the performance of the qualification testing requirements specified herein. Terminal lugs and splices produced with equipment and procedures
22、 normally used in production shall be subjected to all the tests in Table 3 in the order shown. The manufacturer shall declare conformity to the requirements herein utilizing the criteria of ISO/IEC Guide 22. TABLE 4 - Qualification Test Sequence Sample Group Number Test Name Requirement Paragraph P
23、rocedure Paragraph 1 2 3 4 5 6 7Examination of Product 3.2.1 5.1.1 X X X X X X XHeat Age 3.2.2 5.1.2 X Temperature Cycling 3.2.3 5.1.3 X Vibration 3.2.4 5.1.4 X Salt Spray 3.2.5 5.1.5 X Voltage Drop 3.2.6 5.1.6 X X X Low Temperature Crimp 3.2.7 5.1.7 X Immersion 3.2.8 5.1.8 X Flammability 3.2.9 5.1.
24、9 X Dielectric Withstanding Voltage 3.2.10 5.1.10 X X X Tensile Strength 3.2.11 5.1.11 X Axial Load 3.2.12 5.1.12 XSAE AS506 - 7 - 4.1.1 Sample Preparation: Samples terminated with the manufacturers recommended tooling as found in Table 7, shall be prepared for testing in accordance with Table 5. Sa
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEAS5062004HIGHTEMPERATUREINSULATEDTERMINALSSPLICES 高温 绝缘 终端 绞接件 PDF

链接地址:http://www.mydoc123.com/p-1024720.html