1、,K- aC-4 0 SAE ARP*84b b5 W 83573LO 0029363 7 W AEROSPACE R ECO M MEN D ED P R ACT1 CE ;OCIETV OF AUTOMOTIVE ENOINEERS. he. 485 LEXINGTON AVENUE NEW YORK ?7s N.Y. LOW TENSION SPARK IGNITER SPARKING VLTAGE TEST ARP 846 IUU 2-10-6s Roviwd 1, PURPOSE - The purpose of these specifications is to provide
2、a standard procedure and standard equipment for the evaluation of a measurement of the ionization voltage (sparking voltage) of shunted surface gap spark igniter designs. 2. SCOPE - These specifications contain general information pertaining to the sparking voltage parameter of shunted surface gap s
3、park igniters; test equipment circuitry; bill of materials for test equipment; test equipment operation. 3. GENERAL CONSIDERATIONS CONCERNING SPARKING VOLTAGE MEASUREMENTS AS A SHUNTED SURFACE SPARK IGNITER PARAMETER 3.1 3i 2 3.3 Spark Igniter Configuration - The low tension type of spark igniter ut
4、ilizes a material classified as a semi-conductor to bridge the gap from the center electrode to the oute: or ground shell. Thus, this design is referred to as the shunted surface gap spark igniter as well as the low tension spark igniter. When the shunted surface material is in good condition and in
5、 intimate contact with the electrodes, the spark igniter gap can be forced to break down (ionize gases between electrodes) at a lower voltage than would occur if the shunt were removed. The voltage required to break down the gap increases with deterioration of the shunted gap material and the deteri
6、oration of the materials contact with the igniter electrodes. Sparking Voltage - By definition, the sparking voltage of a particular shunted surface gap spark igniter design is the lowest voltage applied to an igniter which will initiate a spark. The term “initiate“ is used since the maintenance of
7、the sparking conditions and energy dissipation is a function of the igniter gap itself and the applied voltage. Sparking voltages may be used as a measure of the condition of shunted surfaces and of contact conditions between electrodes and surface. It is also conceivable that sparking voltages may
8、be used as an indicator of life expectancy of new and used spark igniters providing that all use-conditions are taken into account. New Spark Igniter Limit - It has been established that for new spark igniters the sparking voltage should be less than 1000 volts under room conditions. This test value
9、 assures that the spark igniter life will be a function of engine environment and use and that the unit has been properly assembled. It must be noted here that spark- ing voltages of a very low magnitude (below 200 volts) may indicate abnormal semi- conductor material conditions. Consideration shoul
10、d therefore be given to establish- ing a minimum as well as a maximum sparking voltage for a given igniter design. 4. TEST EQUIPMENT FOR MEASURING LOW TENSION SPARK IGNITER SPARKING VOLTAGES 4.1 General Test Procedure - .- CODYrhht 1g65 )r Oodotu o Automotko Lnrlnoorr. Ina Printed in U 1. A. - _ SAE
11、 ARP*84b b5-i 8357340 00273b2 3 IMU 2-10-65 LOW TENSION SPARK IGNITER SPARKING VOLTAGE TEST -2- 4.1.1 New Spark Igniters - A new spark igniter, when connected to a power source con- sisting o cr previously charged O. 5 microfarad capacitor at 1000 volts maximum, shall produce a readily visible spark
12、 between the two metal electrodes. It is rec- ommended that a minimum of five (5) successive sparks be used to establish com- pliance to the maximum voltage requirements. 4.1.2 Old Spark Ignitrs - The test equipment must be capable of applying voltages adjust- ed between 1000 volts (for new spark ig
13、niters) and 5000 volts. The test operator shall us0 his experience to determine the voltage level that the O. 5 microfarad capacitor is to be charged to for the teat. Repetitive tests parallel to that for new spark igniters niay be used to determine the actual sparking voltage or the test may be con
14、fined to determining if the sparking voltage is less than a specified limit. 4,2 4.2. 4.2.2 Tost Equipment General - The output characteristics of the spark igniter tester shall be such, that when it imposes a positive pulse across a O, 3 ohm resistor (inductance rating O. 35 to O. 375 microhenry at
15、 10 kc) from a O. 5 microfarad capacitor charged to 2000 v, tho voltage rise across the resistor shall exceed 200 v within a time period of 1.5 microseconds. (Reference: Tektronic Scope No. 531 or equivalent may be used to rnoatmro the voltage rise or if the voltage rise is too high for this equipme
16、nt a Tektronio High Voltage Probe No. P6002, Part Number 010-024 or equivalent may be used,) -c- NOTE: A negative pulse may be used instead of a positive pulse; however, one polarity must be chosen, as it is felt that difference may exist and an igniter measured ns satisfactory on one may be unsatis
17、factory on the other, “he test equipment circuit described in this document is one of many possible cir- cuit deisigns which would satisfy the above requirements. Circuit Description - The test equipment designed to accomplish the general test functions has three major circuit elements: input circui
18、t, power circuit and oscil- lator circuit. These circuit elements are connected to charge and/or discharge a O. fi microfarad capacitor to voltage levels from O to 5000 v d-c at a discharge rate of approximately two (2) sparks per second. The detailed circuit schematic is shown in Figure 1, “he teet
19、er consists of a main housing which contains the circuitry shown on the schematic diagram and an adapter box which provides for enclosure of the test piecs. S-3 is an interlock switch that is incorporated in the cover of the main housing and S-4, also an interlock switch, is mounted in the enclosure
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEARP8461965LOWTENSIONSPARKIGNITERSPARKINGVOLTAGETEST 张力 点火器 触发 电压 测试 PDF

链接地址:http://www.mydoc123.com/p-1023315.html