SAE ARP 5015A-2003 Ground Equipment - 400 Hertz Ground Power Performance Requirements《地面设备 400Hz地面电源性能要求》.pdf
《SAE ARP 5015A-2003 Ground Equipment - 400 Hertz Ground Power Performance Requirements《地面设备 400Hz地面电源性能要求》.pdf》由会员分享,可在线阅读,更多相关《SAE ARP 5015A-2003 Ground Equipment - 400 Hertz Ground Power Performance Requirements《地面设备 400Hz地面电源性能要求》.pdf(15页珍藏版)》请在麦多课文档分享上搜索。
1、SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirelyvoluntary, and its applicability and suitability for any particular use, including any patent infringement arising therefro
2、m, is the sole responsibility of the user.”SAE reviews each technical report at least every five years at which time it may be reaffirmed, revised, or cancelled. SAE invites your written comments and suggestions.Copyright 2011 SAE InternationalAll rights reserved. No part of this publication may be
3、reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE.TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada)Tel: 724-776-4970 (outside USA)Fax: 724
4、-776-0790Email: custsvcsae.orgSAE WEB ADDRESS: http:/www.sae.orgAEROSPACE RECOMMENDEDPRACTICEARP5015REV.AIssued 1996-06Revised 2003-04Superseding ARP5015Ground Equipment - 400 Hertz Ground Power Performance RequirementsTABLE OF CONTENTS1. SCOPE .22. APPLICABLE DOCUMENTS22.1 SAE Publications .22.2 AN
5、SI Publications 32.3 U.S. Government Publications.32.4 UL Publications32.5 NEMA Publications 32.6 IEC Publications 32.7 ATA Publications32.8 Other Publications .42.9 Definitions and Abbreviations 43. TECHNICAL REQUIREMENTS .73.1 Equipment Specifications 73.2 Personnel Safety .103.3 Equipment Protect
6、ion 113.4 Interface Requirements123.5 Tools and Test Equipment123.6 Design and Construction .124. INSTALLATION OPERATION AND MAINTENANCE.155. NOTES .15FIGURE 1 Voltage Compliance and Protection 9FIGURE 2 Frequency Compliance and Protection . 11SAE values your input. To provide feedback on this Techn
7、ical Report, please visit http:/www.sae.org/technical/standards/ARP5015AReaffirmed 2011-01SAE ARP5015 Revision A- 2 -1. SCOPE:1.1 This SAE Aerospace Recommended Practice (ARP) covers the requirements for ground power equipment that supplies 115/200 V, 3-phase, 400 Hz output capable of powering aircr
8、aft type loads requiring MIL-STD-704E/DFS-400 quality power. All forms of ground power including mobile and fixed systems are addressed by this document. High voltage (270 V DC) systems are not included in this specification.1.2 The intent of this document is to provide specifications for engine gen
9、erators, motor generators, and solid-state converters tailored for performance with modern aircraft, applicable to all unless otherwise noted. Modern aircraft are requiring more power at a higher quality without interruption which places new constraints such as No-Break-Power-Transfer (NBPT) operati
10、on on the ground power units (GPUs). The protective trip limits are designed to allow a two tier protection utilizing both the aircrafts electrical power generating systems (EPGS) and the GPUs protection. Some of these specifications will place some new design constraints on the manufacturers of GPU
11、s but will help promote compatibility with old and new aircraft with all types of ground power equipment.1.3 While GPUs are designed to provide the same quality of power as the aircrafts EPGS, there are differences in rated capacity. Engines utilized in GPUs must be sized for the peak kW specified w
12、hich is why a 125% overload is specified for GPUs. Increasing the size of the engine to match the aircrafts EPGS typical 150 to 200% overload rating would not be practical. The 150 to 200% overload rating is designed for abnormal conditions (such as fault clearing) and the use of a GPU to clear airc
13、raft on-board faults is not recommended. GPUs that utilized engine generators are also self-excited which implies that they are not capable of providing output under excessive fault current since their output voltage is utilized to excite the generator. Most aircraft EPGS have a permanent magnet pil
14、ot machine that provides the excitation supply to allow for fault clearing current. GPUs are typically rated for a 0.8 power factor which differs from aircraft EPGS which are rated at 0.75 PF. An engine generator will have to have slightly larger engine to accommodate a 0.8 PF when compared to a 0.7
15、5 PF which infers that 0.8 is actually a conservative rating for GPUs.2. APPLICABLE DOCUMENTS:The following publications form a part of this document to the extent specified herein. The latest issue of SAE publications shall apply. The applicable issue of other publications shall be the issue in eff
16、ect on the date of the purchase order. In the event of conflict between the text of this document and references cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained.2.1 S
17、AE Publications:Available from SAE, 400 Commonwealth Drive, Warrendale, PA 15096-0001.ARP1247A General Requirements for Aerospace Powered Mobile GroundJ1175 Bystander Sound Level Measurement ProcedureSAE ARP5015 Revision A- 3 -2.2 ANSI Publications:Available from ANSI, 25 West 43rd Street, New York,
18、 NY 10036-8002.ISO 1540 Aerospace - Characteristics for Aircraft Electrical SystemsISO 6858 Ground Support Electrical Supplies - General Requirements2.3 U.S. Government Publications:Available from DODSSP, Subscription Services Desk, Building 4D, 700 Robbins Avenue, Philadelphia, PA 19111-5094.MIL-G-
19、21480A Generators and Regulators, Air-cooled, AC, EquipmentMIL-STD-461 Electromagnetic Interface Characteristic Requirements for EquipmentMIL-STD-704E Electric Power, Aircraft, Characteristics and Utilization of 2.4 UL Publications:Available from Underwriter Laboratories Publications, 333 Pfingsten
20、Road, Northbrook, IL 60062.UL 1446-1980 Systems of Insulating Materials - General Revised 3/862.5 NEMA Publications:Available from National Electrical Manufacturers Association, 2101 L Street, NW, Washington, DC 20037.NEMA MG-1 NEMA Standards Publication - Motor and Generators (N/A to Solid-State)NE
21、MA PE-1 Uninterruptable Power Systems2.6 IEC Publications:Available from International Electrotechnical Commission, 3. rue de Varembe. CH-1211 Geneve 20 Switzerland.IEEE-519 Guide for Harmonic Control and Reactive Compensation of Static Converters2.7 ATA Publications:Available from Air Transport Ass
22、ociation, 1709 New York Avenue NW, Washington, DC 20006ATA-Spec 101 Specification for Ground Power Equipment Technical DataSAE ARP5015 Revision A- 4 -2.8 Other Publications:AN-3114, AN-3440 Army/Navy 6-Pole Socket/Plug Reqmts. (MS90362-MS25486 Cable:MS90328)BSI 2G-219 General Requirements for Ground
23、 Support Electrical Supplies for AircraftDFS-400 Eurostandard 400 Hertz Systems2.9 Definitions and Abbreviations:This glossary of terms is included as part of this document for use in its interpretation.ADJUSTABLE VOLTAGE RANGE: The range in adjustment as controlled by the regulator to enable checki
24、ng over and under voltage protection devices.ALTERNATOR SPEED: The nominal speed at which the alternator operates to produce 400 Hz.ALTITUDE: The maximum height in feet above sea level at which the unit must operate and maintain characteristics within recommended limits.AMBIENT TEMPERATURE RATING: T
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEARP5015A2003GROUNDEQUIPMENT400HERTZGROUNDPOWERPERFORMANCEREQUIREMENTS 地面 设备 400 HZ 电源 性能 要求 PDF

链接地址:http://www.mydoc123.com/p-1023023.html