《REG NASA-LLIS-1111-1999 Lessons Learned International Space Station Program Extravehicular Activity (EVA) Pyrotechnic Initiators.pdf》由会员分享,可在线阅读,更多相关《REG NASA-LLIS-1111-1999 Lessons Learned International Space Station Program Extravehicular Activity (EVA) Pyrotechnic Initiators.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Lessons Learned Entry: 1111Lesson Info:a71 Lesson Number: 1111a71 Lesson Date: 1999-02-01a71 Submitting Organization: HQa71 Submitted by: David M. LengyelSubject: International Space Station Program/Extravehicular Activity (EVA)/Pyrotechnic Initiators Description of Driving Event: Use of “Fire-Evide
2、nt“ Pyrotechnic InitiatorsLesson(s) Learned: Many deployable structures on the ISS and satellites on which astronauts must work during EVAs use pyrotechnic initiators. There is often no simple way for an EVA astronaut to know by visual inspection whether or not an initiator has fired when a structur
3、e has failed to deploy properly.Recommendation(s): NASA should develop and require the use of pyrotechnic initiators that leave clear visual evidence that they have fired. These “fire-evident“ initiators should be required for all applications that may be encountered by an EVA astronaut.Evidence of
4、Recurrence Control Effectiveness: The NASA Standard Initiator (NSI) is required for use in all electrically initiated pyrotechnic systems whether the application may be encountered by an EVA astronaut or not. The NSI does not provide any means for external visual inspection of fired condition when i
5、t is installed in a mechanism. Currently, the only test being performed to verify that the initiator fired, without disassembly of the pyrotechnic mechanism, is to measure firing circuit resistance before and after firing. This function can be built into the firing unit. It is not foolproof however,
6、 since it cannot detect a smart short. To date this has not been a problem with the NSI since in nearly 100,000 units produced and certified there are no documented failures. That is why the NSI carries a reliability of 0.999 at a 90% confidence level. All failures to fire have been traced directly
7、to the electrical wiring, Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-connectors, firing unit or flight computer. Breaks in the electrical firing circuit can be identified by a pre-fire circuit resistance check.The desire of visual identification
8、 is further compounded by the physical location of the initiator. In many applications it is located internal to a mechanism and is not directly accessible or visible. For those applications where it is external to the mechanism it is still not visible since half the device is torqued into the mecha
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- REGNASALLIS11111999LESSONSLEARNEDINTERNATIONALSPACESTATIONPROGRAMEXTRAVEHICULARACTIVITYEVAPYROTECHNICINITIATORSPDF

链接地址:http://www.mydoc123.com/p-1018750.html