《PPI MS-5-2008 HDPE Solid Wall Conduit Model Specification Power and Communications Conduit and Casing《实心壁高密度聚乙烯(HDPE)导管型号规格 电力和通信导管和套管》.pdf》由会员分享,可在线阅读,更多相关《PPI MS-5-2008 HDPE Solid Wall Conduit Model Specification Power and Communications Conduit and Casing《实心壁高密度聚乙烯(HDPE)导管型号规格 电力和通信导管和套管》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、 105 Decker Court, Suite 825, Irving, TX 75062 P: 469-499-1044 F: 469-499-1063 www.plasticpipe.org MS-5/2008 HDPE Solid Wall Conduit Model Specification Power and Communications Conduit and Casing 2 March 2008 HDPE Solid Wall Conduit Model Specification Power and Communications Conduit and Casing Th
2、e user may choose to adopt part or all of this Model Specification; however, the user should ensure that all parts used are appropriate for the users purpose. See notice below. 1. General Terms and Conditions 1.1. Scope: This specification covers requirements for flexible solid wall high-density pol
3、yethylene (HDPE) communications and power conduit and casing manufactured according to ASTM F 2160 for above ground use and below ground use by direct burial or trenchless installation. 1.2. Engineered and Approved Plans: Communications and power conduit and casing installation and construction shal
4、l be performed in accordance with engineered construction plans for the work prepared under the direction of a Professional Engineer. 1.3. Referenced Standards: Where all or part of a Federal, State or Local, ASTM, ANSI, NEMA, UL, etc., standard specification is incorporated by reference in these Sp
5、ecifications, the reference standard shall be the latest edition and revision. 1.4. Licenses and Permits: A licensed and bonded General Contractor shall perform all communications and power conduit and casing construction work. The Contractor shall secure all necessary permits before commencing cons
6、truction. 1.5. Inspections: All work shall be inspected by an Authorized Representative of the Owner who shall have the authority to halt construction if, in this opinion, these specifications or standard construction practices are not being followed. Whenever any portion of these specifications is
7、violated, the Project Engineer or his Authorized Representative shall, by written notice order further construction to cease until all deficiencies are corrected. A copy of the order shall be filed with the Contractors license application for future review. If the deficiencies are not corrected, per
8、formance shall be required of the Contractors surety. NOTICE: This publication is intended for use as a guide to support the designer of conduit systems, but it should not be used in place of the advice of a professional engineer. The Plastics Pipe Institute has made every reasonable effort to ensur
9、e the accuracy of this publication, but is may not provide all necessary information, particularly with respect to special or unusual applications. This publication may be changed from time to time without notice. Contact the Plastics Pipe Institute to determine if you have the most current edition.
10、 2. High Density Polyethylene Solid-Wall Conduit and Casing 3 March 2008 2.1. Qualification of manufacturers: The manufacturer shall have manufacturing and quality control facilities that are capable of producing and assuring the quality of the conduit or casing required by these specifications. The
11、 manufacturers production facilities shall be open for inspection by the owner or his Authorized Representative. The conduit and casing manufacturer shall have a documented quality management system that defines product specifications and manufacturing and quality assurance procedures that assure co
12、nformance with customer and applicable regulatory requirements. 2.2. Approved Manufacturers: Manufacturers that are qualified and approved by the Project Engineer are listed below. Products from unapproved manufacturers may be submitted for approval at the discretion of the Project Engineer. . (Inse
13、rt Company Name and Address of approved suppliers.) 2.3. Materials: Materials used for the manufacture of polyethylene conduit and casing shall be high-density polyethylene in accordance with ASTM F2160 requirements. Non-black materials shall not be used above ground 2.4. Size and Dimensions: HDPE c
14、onduit and casing shall be manufactured to the dimensions and requirements of ASTM F2160. 2.4.1. Other sizes and requirements shall be acceptable by advance mutual agreement between the customer (Owner, Purchaser or Project Engineer as appropriate) and the manufacturer. (Note: Purchaser input condui
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- PPIMS52008HDPESOLIDWALLCONDUITMODELSPECIFICATIONPOWERANDCOMMUNICATIONSCONDUITANDCASING 实心 高密度 聚乙烯 HDPE

链接地址:http://www.mydoc123.com/p-1016752.html