NAVY UFGS-10 22 26 13-2010 ACCORDION FOLDING PARTITIONS《可折叠的隔板》.pdf
《NAVY UFGS-10 22 26 13-2010 ACCORDION FOLDING PARTITIONS《可折叠的隔板》.pdf》由会员分享,可在线阅读,更多相关《NAVY UFGS-10 22 26 13-2010 ACCORDION FOLDING PARTITIONS《可折叠的隔板》.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、*USACE / NAVFAC / AFCESA / NASA UFGS-10 22 26.13 (August 2010)-Preparing Activity: NAVFAC Superseding UFGS-10 22 26.13 (October 2007)UFGS-10 22 26.13 (April 2006)UFGS-10 22 26.13 40 (October 2006)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2010*SECTION TAB
2、LE OF CONTENTSDIVISION 10 - SPECIALTIESSECTION 10 22 26.13ACCORDION FOLDING PARTITIONS08/10PART 1 GENERAL1.1 REFERENCES1.2 SUBMITTALS1.3 PRE-INSTALLATION REQUIREMENTS1.3.1 Preconstruction Requirements1.3.2 Product Data1.3.3 Manufacturers Guarantee1.3.4 SUSTAINABLE DESIGN CERTIFICATION1.4 DELIVERY, H
3、ANDLING AND STORAGEPART 2 PRODUCTS2.1 FOLDING PARTITIONS2.2 MATERIALS2.2.1 Aluminum Extrusions2.2.2 Steel Sheets2.2.3 Fabric Covering2.2.4 Seals and Sweepstrips2.2.5 Ceiling Guards2.3 PERFORMANCE REQUIREMENTS2.3.1 Fire Endurance2.3.2 Laboratory Acoustical Requirements2.4 ELECTRICAL OPERATORS2.5 FABR
4、ICATION2.5.1 Framework2.5.2 Suspension System2.5.3 Covering2.5.4 Sound Insulation2.5.5 Air Release2.5.6 Seals2.5.7 Hardware2.5.8 AccessoriesSECTION 10 22 26.13 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-PART 3 EXECUTION3.1 INSTALLATION3.1.
5、1 Existing Work3.1.2 Electrical Operators3.1.3 Adjustment3.2 FIELD TESTS3.2.1 Operational Test3.2.2 Visual Test3.2.3 Acoustical Test3.3 CLEANING3.4 SUPPORT SERVICE- End of Section Table of Contents -SECTION 10 22 26.13 Page 2Provided by IHSNot for ResaleNo reproduction or networking permitted withou
6、t license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-10 22 26.13 (August 2010)-Preparing Activity: NAVFAC Superseding UFGS-10 22 26.13 (October 2007)UFGS-10 22 26.13 (April 2006)UFGS-10 22 26.13 40 (October 2006)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL date
7、d July 2010*SECTION 10 22 26.13ACCORDION FOLDING PARTITIONS08/10*NOTE: This guide specification covers the requirements for accordion folding partitions, manually and/or electrically operated.Accordion partitions are folding partitions with independent covers enclosing a dead-air space and separated
8、 by an internal mechanism operating laterally across the face of the opening to a stack or closed position. Do not confuse accordion partitions with serpentine folding partitions which contain no internal operating mechanism or dead-air space between independent covers.Folding partitions may be a si
9、ght barrier (noninsulated), or sound barrier (with sound liner), or both. Accordion-folding partitions have fabric covers which are joined to reflect a pantographic movement of the door surfaces when the door is either manually or electrically operated.This section does not include folding or operab
10、le walls and partitions whose rigid panels are individually moved or hinged along their vertical edges to fold in serpentine fashion.Associated work found in other sections includes:Steel supporting members or hanger rods, Section 05 50 13 MISCELLANEOUS METAL FABRICATIONSSection 05 51 33 METAL LADDE
11、RSSection 05 52 00 METAL RAILINGSSection 05 51 00 METAL STAIRS.Wood blocking, rough bucks, and headers, Section 06 10 00 ROUGH CARPENTRY.Wood trim, wood or hardboard ceiling guard, or soffits, Section 06 20 00 FINISH CARPENTRY.Lock cylinders, Section 08 71 00 DOOR HARDWARE.SECTION 10 22 26.13 Page 3
12、Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Operator field connections to power sources and inner connection to control switches, Division 16, “Electrical.“Edit this guide specification for project specific requirements by adding, deleting, or re
13、vising text. For bracketed items, choose applicable item(s) or insert appropriate information.Remove information and requirements not required in respective project, whether or not brackets are present.Comments and suggestions on this guide specification are welcome and should be directed to the tec
14、hnical proponent of the specification. A listing of Technical Proponents, including their organization designation and telephone number, is on the Internet.Recommended changes to a UFGS should be submitted as a Criteria Change Request (CCR).*NOTE: The following information should be shown on the dra
15、wings:1. Location, size, and folding area of accordion partitions.2. Direction of operation, header conditions indicating height, track anchorage, track channel, and jamb conditions.3. Partition supporting structure. The structural support for the partition is not part of this section; it must be in
16、dicated and specified separately.4. A schedule of partitions by type, sizes, and stack space and identified by mark number or letter5. For electrically operated partitions, show power source and desired switch location.*PART 1 GENERAL1.1 REFERENCES*NOTE: This paragraph is used to list the publicatio
17、ns cited in the text of the guide specification. The publications are referred to in the text by basic designation only and listed in this paragraph by organization, designation, date, and title.SECTION 10 22 26.13 Page 4Provided by IHSNot for ResaleNo reproduction or networking permitted without li
18、cense from IHS-,-,-Use the Reference Wizards Check Reference feature when you add a RID outside of the Sections Reference Article to automatically place the reference in the Reference Article. Also use the Reference Wizards Check Reference feature to update the issue dates.References not used in the
19、 text will automatically be deleted from this section of the project specification when you choose to reconcile references in the publish print process.*The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the b
20、asic designation only.ASTM INTERNATIONAL (ASTM)ASTM A 653/A 653M (2009a) Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip ProcessASTM B 221 (2008) Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire,
21、 Profiles, and TubesASTM B 221M (2007) Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes (Metric)ASTM C 423 (2009a) Sound Absorption and Sound Absorption Coefficients by the Reverberation Room MethodASTM D 751 (2006) Coated FabricsASTM E 336 (2009)
22、 Measurement of Airborne Sound Insulation in BuildingsASTM E 413 (2004) Rating Sound InsulationASTM E 557 (2000; R 2006) Installation of Operable PartitionsASTM E 84 (2010) Standard Test Method for Surface Burning Characteristics of Building MaterialsASTM E 90 (2009) Standard Test Method for Laborat
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。