NAVY UFGS-07 41 13-2011 METAL ROOF PANELS《金属屋面板》.pdf
《NAVY UFGS-07 41 13-2011 METAL ROOF PANELS《金属屋面板》.pdf》由会员分享,可在线阅读,更多相关《NAVY UFGS-07 41 13-2011 METAL ROOF PANELS《金属屋面板》.pdf(41页珍藏版)》请在麦多课文档分享上搜索。
1、*USACE / NAVFAC / AFCESA /NASA UFGS-07 41 13 (May 2011)-Preparing Activity: NAVFAC SupersedingUFGS-07 41 13 (November 2008)UFGS-07 41 13 (January 2008)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2011*SECTION TABLE OF CONTENTSDIVISION 07 - THERMAL AND MOIST
2、URE PROTECTIONSECTION 07 41 13METAL ROOF PANELS05/11PART 1 GENERAL1.1 REFERENCES1.2 DESCRIPTION OF METAL ROOF SYSTEM1.2.1 Performance Requirements1.2.1.1 Hydrostatic Head Resistance1.2.1.2 Wind Uplift Resistance1.3 SUBMITTALS1.4 QUALITY ASSURANCE1.4.1 Qualification of Manufacturer1.4.1.1 Manufacture
3、rs Technical Representative1.4.1.2 Single Source1.4.2 Qualification of Applicator1.4.3 Field Verification1.4.4 Qualifications for Welding Work1.4.5 Pre-roofing Conference1.5 DELIVERY, HANDLING, AND STORAGE1.5.1 Delivery1.5.2 Handling1.5.3 Storage1.6 PROJECT CONDITIONS1.7 FABRICATION1.7.1 Finishes1.7
4、.2 Accessories1.8 WARRANTIES1.8.1 Metal Roof Panel Manufacturer Warranty1.8.2 Manufacturers Finish Warranty1.8.3 Metal Roof System Installer Warranty1.8.4 Continuance of Warranty1.9 CONFORMANCE AND COMPATIBILITY1.10 SCHEDULEPART 2 PRODUCTS2.1 ROOF PANELSSECTION 07 41 13 Page 1Provided by IHSNot for
5、ResaleNo reproduction or networking permitted without license from IHS-,-,-2.1.1 Aluminum Sheet Panels2.1.2 Steel Sheet Panels2.2 FACTORY FINISH AND COLOR PERFORMANCE REQUIREMENTS2.2.1 Specular Gloss2.3 MISCELLANEOUS METAL FRAMING2.3.1 General2.3.2 Fasteners and Miscellaneous Metal Framing2.3.2.1 Ex
6、posed Fasteners2.3.2.2 Screws2.3.2.3 Rivets2.3.2.4 Attachment Clips2.3.3 Electrodes for Manual, Shielded Metal Arc Welding2.4 ACCESSORIES2.4.1 Pre-manufactured Accessories2.4.2 Metal Closure Strips2.4.3 Rubber Closure Strips2.4.4 Subgirts for Retrofits2.5 JOINT SEALANTS2.5.1 Sealants2.5.1.1 Shop App
7、lied Sealants2.5.1.2 Field Applied Sealants2.5.1.3 Tape Sealants2.5.2 Sheet Metal Flashing and Trim2.5.2.1 Fabrication, General2.5.2.2 Roof Drainage Sheet Metal Fabrications2.6 INSULATION2.6.1 Fire Rated Assembly System2.6.2 Fire Rated Roof Panel Assembly2.7 UNDERLAYMENTS2.7.1 Felt Underlayment2.7.2
8、 Self-Adhering Modified Bitumen Underlayment2.7.3 EPDM Membrane2.7.4 Slip Sheet2.8 GASKETS AND SEALING/INSULATING COMPOUNDS2.9 FINISH REPAIR MATERIALPART 3 EXECUTION3.1 EXAMINATION3.2 INSTALLATION3.2.1 Preparation3.2.2 Underlayment3.2.2.1 Single Layer Felt Underlayment for a Standard Slope Roof Deck
9、3.2.2.2 Self-Adhering Sheet Underlayment3.2.2.3 Slip Sheet3.3 INSULATION INSTALLATION3.4 PROTECTION OF APPLIED MATERIALS3.5 FASTENER INSTALLATION3.5.1 Welding3.6 FLASHING, TRIM, AND CLOSURE INSTALLATION3.6.1 General Requirements3.6.2 Metal Flashing3.7 ROOF PANEL INSTALLATION3.7.1 Handling and Erecti
10、on3.7.2 Closure Strips3.7.3 Workmanship3.8 ACCEPTANCE PROVISIONS3.8.1 Erection TolerancesSECTION 07 41 13 Page 2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-3.8.2 Leakage Tests3.8.3 Repairs to Finish3.8.4 Paint Finished Metal Roofing3.9 CLEAN UP A
11、ND DISPOSAL3.10 FIELD QUALITY CONTROL3.10.1 Manufacturers Inspection3.11 INFORMATION CARD3.11.1 Form One3.12 DATE OF INSTALLATION WALL-MOUNTED PLACARD3.13 USACE WARRANTY- End of Section Table of Contents -SECTION 07 41 13 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted wit
12、hout license from IHS-,-,-*USACE / NAVFAC / AFCESA /NASA UFGS-07 41 13 (May 2011)-Preparing Activity: NAVFAC SupersedingUFGS-07 41 13 (November 2008)UFGS-07 41 13 (January 2008)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2011*SECTION 07 41 13METAL ROOF PAN
13、ELS05/11*NOTE: This guide specification covers the requirements for both factory color and mill finish aluminum or steel non-structural metal roofing.Adhere to UFC 1-300-02 Unified Facilities Guide Specifications (UFGS) Format Standard when editing this guide specification or preparing new project s
14、pecification sections. Edit this guide specification for project specific requirements by adding, deleting, or revising text. For bracketed items, choose applicable items(s) or insert appropriate information.Remove information and requirements not required in respective project, whether or not brack
15、ets are present.Comments, suggestions and recommended changes for this guide specification are welcome and should be submitted as a Criteria Change Request (CCR).*NOTE: Non-Structural Metal Roofing is also referred to as architectural metal roofing or hydrokinetic metal roofing. Seam profiles includ
16、e standing seam and lapped seam. Apply roof panels over a solid substrate (roof deck) with an appropriate underlayment.This specification may also be used for metal roof panels on auxiliary structures including light storage and open air shed roofs with some modification for application of corrugate
17、d or fluted panels over support structure without decking.Structural standing seam panels, insulated sandwich panels and special systems such as copper, stainless steel, or terne metal are not covered in this guide specification.SECTION 07 41 13 Page 4Provided by IHSNot for ResaleNo reproduction or
18、networking permitted without license from IHS-,-,-Coordinate this section with other system components specifications such as framing, decking, insulation and sheet metal flashing. Also coordinate with the criteria of UFC 3-110-03, “Design: Roofing“ as it relates to the specific project and Service
19、Exceptions indicated therein. For Army projects also refer to UFC 3-320-03A, “Structural Considerations for Metal Roofing“. *PART 1 GENERAL1.1 REFERENCES*NOTE: This paragraph is used to list the publications cited in the text of the guide specification. The publications are referred to in the text b
20、y basic designation only and listed in this paragraph by organization, designation, date, and title.Use the Reference Wizards Check Reference feature when you add a RID outside of the Sections Reference Article to automatically place the reference in the Reference Article. Also use the Reference Wiz
21、ards Check Reference feature to update the issue dates.References not used in the text will automatically be deleted from this section of the project specification when you choose to reconcile references in the publish print process.*The publications listed below form a part of this specification to
22、 the extent referenced. The publications are referred to within the text by the basic designation only.ALUMINUM ASSOCIATION (AA)AA ADM-105 (2005; Errata 2005) Aluminum Design ManualAMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC)ANSI/AISC 341 (2005; Suppl No. 1 2005) Seismic Provisions for Structural
23、 Steel BuildingsAMERICAN IRON AND STEEL INSTITUTE (AISI)AISI S100 (2007; Supp 1: 2009; Supp 2: 2010) North American Specification for the Design of Cold-Formed Steel Structural MembersAISI SG03-3 (2002; Suppl 2001-2004; R 2008) Cold-Formed Steel Design Manual SetSECTION 07 41 13 Page 5Provided by IH
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYUFGS0741132011METALROOFPANELS 金属 屋面板 PDF

链接地址:http://www.mydoc123.com/p-984724.html